HomeMy WebLinkAboutCOC Packet 2025-09-11
PLANNING DEPARTMENT
215 N. Tioga St 14850
607.273.1747
www.townithacany.gov
9/5/2025
TO: Codes and Ordinances Committee:
Bill Arms
Chris Jung
Eva Hoffmann
Margaret Johnson
Susie Gutenberger-Fitzpatrick
Rob Rosen, Chair
FROM: C.J. Randall, Director of Planning
RE: Next Codes and Ordinances Committee Meeting September 11, 2025
The next meeting of the Codes and Ordinances Committee is scheduled for Thursday,
September 11, 2025, at 5:30 pm in the Town Board Room, located in Town Hall at 215 North
Tioga Street. A quorum of the Town of Ithaca Town Board may be present at this meeting.
However, no official Town Board business will be conducted.
The draft minutes from the July 10, 2025, COC meeting are attached.
If you cannot attend this meeting, please notify Abby Homer as soon as possible at (607) 273-
1747, or ahomer@townithacany.gov.
cc: Susan H. Brock, Attorney for the Town
C.J. Randall, Director of Planning
Marty Moseley, Director of Code Enforcement
Abby Homer, Administrative Assistant
Paulette Rosa, Town Clerk (email)
Town Administrative staff (email)
Town Code Enforcement staff (email)
Town Planning staff (email)
Town Public Works staff (email)
Media
TOWN OF ITHACA CODES AND ORDINANCES COMMITTEE
215 North Tioga Street
Ithaca, New York 14850
(607) 273-1747
PLEASE NOTE: This meeting will be held in person in the Town Board Room at Town Hall, 215
North Tioga Street, Ithaca, NY, on September 11, 2025, at 5:30pm.
Members of the public may join the meeting via Zoom:
Join Zoom meeting: https://us06web.zoom.us/j/87531393743
Zoom meeting ID: 875 3139 3743
Dial in phone: 929-436-2866
Meeting of September 11, 2025– 5:30 P.M.
AGENDA
1. Member comments/concerns.
2. Review draft minutes from July 10, 2025, COC meeting.
3. Presentation and Review of proposed amendments to Accessory Buildings in the
following Zones: Conservation (Town Code § 270-17); Low Density Residential
(Town Code § 270-60); Medium Density Residential (Town Code § 270-71); and
High Density Residential (Town Code § 270-82).
4. Review of proposed amendment to Zoning Administration: Permit to Build (Town
Code § 270-233B).
5. Other business:
Next meeting agenda.
Town of Ithaca Planning Department
September 5, 2025
1
TOWN OF ITHACA
CODES AND ORDINANCES COMMITTEE (COC)
Meeting of July 10, 2025 – 5:30 p.m.
Shirley A. Raffensperger Board Room, Town Hall
Draft Minutes
Members Present: Rob Rosen, Chair; Bill Arms; Chris Jung; Eva Hoffmann; Susie Gutenberger-
Fitzpatrick; Margaret Johnson.
Staff Present: C.J. Randall, Director of Planning; Dana Magnuson, Senior Code Officer; Marty Moseley,
Director of Code Enforcement; Susan Brock, Attorney for the Town.
Guests: None
The meeting was recorded on Zoom and streamed live on the Town of Ithaca YouTube channel.
1. Privilege of the Floor. Rob noted there was a person who expressed interest in addressing the committee,
however no one was in attendance in person or on Zoom. Side entrances to the Town Hall were checked to be
sure there were no guests waiting.
2. Member comments/concerns. None.
3. Review minutes from May 8, 2025, COC meeting. Susan Brock suggested minor changes. Rob
moved to accept the minutes, Chris seconded. All members voted in favor to accept May 8, 2025, COC
meeting minutes as amended.
4. Review of proposed amendments to Accessory Buildings in the following Zones: Conservation (Town
Code § 270-17); Low Density Residential (Town Code § 270-60); Medium Density Residential (Town
Code § 270-71); and High Density Residential (Town Code § 270-82). Draft amendments to the
respective Yard Regulations sections for each of the aforementioned Zones were provided to the
committee as well as a chart with the Town of Ithaca front, side, and rear yard dimensional requirements
with columns for garages, accessory buildings, and woodsheds by zoning district.
Rob explained that a lot of property owners have been seeking variances for shed placement and the
variances have been granted. This prompted a proposal to amend the code to reduce the frequency of
these types of area variance applications. Marty added that the Zoning Board of Appeals passed a
resolution in June 2024 referring to the matter to the Town Board and the Town Board subsequently
asked for the COC’s input.
Marty summarized the proposed amendments and associated background research. There was a straw poll
to indicate whether members wanted to consider recommending an increase to five feet from any side or
rear lot line in the Medium and High Density Residential zones; the current language requires accessory
buildings be not less than three feet. The majority of the committee members did not want to pursue the
change.
C.J. mentioned community character and potential considerations for regulating the form of the accessory
structure types, such as height, roof styles, materiality, dimensional requirements, etc. She offered to
2
investigate these factors if they were of concern to the committee. Rob replied that he did not feel the
town is ready to regulate the appearance of sheds. Chris agreed that it would seem like too much
regulation.
Marty went over the thresholds that triggered a building permit for accessory buildings. This was not in
the sections proposed for revisions however the committee discussed the height in detail. The size of 144
sq.ft.or larger comes from NYS code and the 12 ft. height maximum is in the Town Chapter 125 along
with additional requirements to trigger a permit. All agreed in the end to leave the 12 ft. height maximum
with the new allowance of sheds in the side yard and remove the existing allowance for up to 20 ft. height
max. Rob asked for that new change to be made in the code. Susan stated the change would be a Town
Board action; she would prepare re-worded language based on the concept discussed. Susan clarified that
sheds exceeding this height in a side yard already could be pre-existing non-conforming; if said structure
did not comply with existing zoning or predated zoning all together it could not be moved or enlarged.
Yard Regulations in Conservation Zones: Susan referred to F.2 and asked if the 400 sq. ft. in area is
cumulative to all accessory buildings in the side yard, are more than one allowed and the total of all is not
to exceed the 400 sq. ft, and whether this law supersedes the other sections which have the cumulative
total of 600 sq. ft. for all accessory buildings on the lot. Marty confirmed the amendments are worded
that the 400 sq. ft. total is to fall under the 600 sq.ft. maximum/cumulative and not supersede it, also
more than one could be permitted. Susan stated she may need to re-word the revisions to be more clear
that more than one could be permitted, not more than 400 sq. ft. total in the side yard, no more than 600
ft. total including the rear lot. For example, two 200 sq. ft. sheds could be in the side yard along with a
third accessory structure in the rear yard up to 200 sq. ft. and still be within the regulations.
Yard regulations in Low Density Residential Zones: Bill asked if there was interest in accommodating
the typical 12’ x 28’ accessory buildings to be in the side yard and increase the proposed amendment from
300 sq. ft. total to 350 sq. ft. Committee members agreed to the change.
5. Review of proposed amendment to extend expiration of variances granted by Zoning Board of
Appeals from 18 months to 36 months (Town Code § 270-235J). A draft of the proposed amendment was
provided to the committee and discussed. Rob explained that applicants are having trouble meeting the
deadline due to various reasons and it is causing unnecessary hardships. Marty added the pandemic
delayed materials and workforce and changing the 18 months to 36 months would match the Town’s Site
Plan Review regulations and proposed subdivision amendments, be consistent as well as give more time
for applicants to build. All were in favor of the proposed amendment. Susan asked for a typical motion
and second to refer the proposed two amendments that the committee has discussed and approved.
Rob moved to approve the referral of the proposed amendments as discussed, Bill seconded. The vote in
favor was unanimous.
6. Other business: The next regularly scheduled meeting is August 14, 2025, however C.J. mentioned that
there are no known agenda items for the August meeting. The revised draft Subdivision regulations are
anticipated back to the committee in September. Cancellation of the August meeting was proposed and
all agreed. C.J. was offered to give the committee an interim update on the revised Subdivision draft in
August rather than cancel the meeting.
Rob made a motion to cancel the August meeting; Bill seconded the motion. The vote in favor was
unanimous.
The meeting adjourned around 6:35 p.m.
§ 270-233 Permit to build.
A. No person, firm, corporation, association or other organization shall commence the
erection, construction, enlargement, alteration, improvement, repair, removal, or
demolition of any building or structure (including signs, except as specified in Article XXIX,
Signs), nor install heating equipment, nor undertake any other work which must conform to
New York State's Uniform Fire Prevention and Building Code or the Energy Code
Supplement found at Chapter 144 of the Code of the Town of Ithaca, without having
applied for and obtained a building permit from a Code Enforcement Officer pursuant to
Chapter 125 of the Code of the Town of Ithaca. Notwithstanding the foregoing, no building
permit shall be required under those circumstances specified in § 125-4A of the Code of
the Town of Ithaca for which no building permit is required.
B. No A permit to build shall may not be issued, as determined by the Director of Code
Enforcement, except pursuant to written order of the Board of Appeals, where the
proposed construction, alteration, or use would be in violation of any provision of this
chapter or would occur on a parcel on which a violation of any provision of this chapter
exists. Notwithstanding the foregoing, this subsection shall not prohibit the issuance of a
permit to repair or replace a roof or another element of a structure that needs such repair
or replacement in order to maintain the structure’s integrity in the determination of the
Director of Code Enforcement, even if there is an existing violation of this chapter on the
parcel. Where a permit to build has been denied, the Zoning Board of Appeals may issue a
written order directing a permit to build be issued, by the Director of Code Enforcement.
§ 270-17 Yard regulations.
Except as may be specifically otherwise authorized in this chapter, in Conservation Zones
yards of at least the following dimensions are required:
A. Front yard: Not less than the average depth of the front yards of building
immediately adjacent. However, except for roadside stands authorized by § 270-
11, the front yard shall not be less than 50 feet nor need it be greater than 75 feet
in depth.
B. Rear yard: Not less than 200 feet in depth.
C. Side yards: Each not less than 50 feet.
D. Greater yards: Notwithstanding the foregoing, any special yard requirements for
specific uses or buildings set forth elsewhere in this chapter shall, if more
restrictive, supersede the above yard provisions.
E. Buffer areas: The foregoing requirements may include any required buffer areas
and shall not be in addition to any required buffer areas.
F. Accessory buildings.
(1) Buildings occupied by a detached accessory dwelling unit. Any such
buildings that are less than 200 feet from a street line must be located in a
rear yard. Any such buildings that are 200 feet or more from a street line may
be located in any yard. All buildings occupied by a detached accessory
dwelling unit must be at least 100 feet from any side lot line and at least 200
feet from a rear lot line.
(2) All other accessory buildings (except garages, and except woodsheds
meeting the requirements of Subsection H below) may not occupy any open
space other than a rear yard. However accessory buildings may be placed in
the side yard where their footprint does not exceed 400 square feet in area
and does not exceed 14 feet in height from the lowest exterior grade and has
a minimum required roof pitch of 4:12.
(3) The total lot area covered by nonagricultural accessory buildings (including
garages and woodsheds) may not occupy more than 1,000 square feet of the
two-hundred-foot rear yard setback required by Subsection B above.
(4) Accessory buildings (other than garages or buildings occupied by a detached
accessory dwelling unit) shall be not less than 50 feet from any side or rear
lot line.
§ 270-60 Yard regulations.
In Low Density Residential Zones yards of at least the following dimensions are required:
A. Front yard: Not less than the average depth of the front yards of buildings on lots
immediately adjacent. However, the front yard depth shall not be less than 30 feet
or need it be greater than 60 feet.
B. Rear yard: Not less than 50 feet in depth.
C. Side yards: Each not less than 40 feet in width.
D. Greater yards: Notwithstanding the foregoing, any special yard requirements for
specific uses or buildings set forth elsewhere in this chapter shall, if more
restrictive, supersede the above yard provisions.
E. Accessory buildings.
a. Buildings occupied by a detached accessory dwelling unit. Any such
buildings must be located in a rear yard, be at least 50 feet from any side lot
line, and be at least 35 feet from a rear lot line.
(2)All other accessory buildings (except garages, and except woodsheds meeting the
requirements of Subsection G below) may not occupy any open space other than a rear
yard.. However accessory buildings may be placed in the side yard where their footprint
does not exceed 3500 square feet in area and does not exceed 14 feet in height from the
lowest exterior grade and has a minimum required roof pitch of 4:12.
(3)Accessory buildings (including garages, woodsheds, and buildings occupied by a
detached accessory dwelling unit), in the aggregate, may occupy not more than 15% of the
fifty-foot rear yard setback required by Subsection B above.
(4)Accessory buildings (except for garages and buildings occupied by a detached
accessory dwelling unit) shall be not less than three feet from any side or rear lot line. Any
accessory building, other than a garage or a building occupied by a detached accessory
dwelling unit, on a corner lot shall be not less than five feet from the rear lot line.
§ 270-71Yard regulations.
In Medium Density Residential Zones yards of at least the following dimensions are
required:
A. Front yard: Not less than the average depth of the front yards of buildings on lots
immediately adjacent. However, the front yard depth shall not be less than 25 feet
or need it be greater than 50 feet.
B. Rear yard: Not less than 30 feet in depth.
C. Side yards: Each not less than 15 feet in width.
D. Greater yards: Notwithstanding the foregoing, any special yard requirements for
specific uses or buildings set forth elsewhere in this chapter shall, if more
restrictive, supersede the above yard provisions.
E. Accessory buildings.
(1) Buildings occupied by a detached accessory dwelling unit. Such buildings must
be located in a rear yard, be at least 30 feet from any side lot line, and be at least
15 feet from a rear lot line.
(2) All other accessory buildings (except garages, and except woodsheds meeting
the requirements of Subsection G below) may not occupy any open space other
than a rear yard.. However accessory buildings may be placed in the side yard
where their footprint does not exceed 200 square feet in area and does not
exceed 14 feet in height from the lowest exterior grade and has a minimum
required roof pitch of 4:12.
(3) Accessory buildings (including garages, woodsheds, and buildings occupied by
a detached accessory dwelling unit), in the aggregate, may occupy not more
than 40% of the thirty-foot rear yard setback required by Subsection B above.
(4) Accessory buildings (except for garages and buildings occupied by a detached
accessory dwelling unit) shall be not less than three feet from any side or rear lot
line. Any accessory building, other than a garage or a building occupied by a
detached accessory dwelling unit, on a corner lot shall be not less than five feet
from the rear lot line.
§ 270-82 Yard regulations.
In High Density Residential Zones yards of at least the following dimensions are required:
A. Front yard: Not less than the average depth of the front yards of buildings on lots
immediately adjacent. However, the front yard depth shall not be less than 25 feet
or need it be greater than 50 feet.
B. Rear yard: Not less than 30 feet in depth.
C. Side yards: Each not less than 10 feet in width.
D. Greater yards: Notwithstanding the foregoing, any special yard requirements for
specific uses or buildings set forth elsewhere in this chapter shall, if more
restrictive, supersede the above yard provisions.
E. Accessory buildings.
(1) Buildings occupied by a detached accessory dwelling unit. Such buildings must
be located in a rear yard, be at least 20 feet from any side lot line, and be at least
15 feet from a rear lot line.
(2) All other accessory buildings (except garages, and except woodsheds meeting
the requirements of Subsection G below) may not occupy any open space other
than a rear yard. However accessory buildings may be placed in the side yard
where their footprint does not exceed 150 square feet in area and does not
exceed 14 feet in height from the lowest exterior grade and has a minimum
required roof pitch of 4:12.
(2)(3) Accessory buildings (including garages, woodsheds, and buildings occupied
by a detached accessory dwelling unit), in the aggregate, may occupy not more
than 40% of the thirty-foot rear yard setback required by Subsection B above.
(3)(4) Accessory buildings (except for garages and buildings occupied by a
detached accessory dwelling unit) shall be not less than three feet from any side
or rear lot line. Any accessory building, other than a garage or a building
occupied by a detached accessory dwelling unit, on a corner lot shall be not less
than five feet from the rear lot line.