HomeMy WebLinkAboutTown of Ithaca Town Hall Mezzanine Contract DrawingsN
T
I
O
G
A
S
T
R
E
E
T
N
A
U
R
O
R
A
S
T
R
E
E
T
E SENECA STREET
AREA OF WORK
E BUFFALO STREET
ITHACA TOWN
HALL
ADJACENT BUILDING
COORDINATE CONTRACTORS
STAGING AREAS IN MECHANICAL
ROOM AND OTHER BASEMENT
ROOMS WITH OWNERS
REPRESENTATIVE.
N.I.C.
BASEMENT DOOR
EXIT
EXIT
EXIT
EXIT
EXIT
DO NOT OBSTRUCT
PASSAGE TO POST
OFFICE
8/
7
/
2
0
2
3
9
:
4
0
:
4
6
A
M
TO
W
N
O
F
I
T
H
A
C
A
2
N
D
F
L
O
O
R
&
C
O
U
R
T
O
F
F
I
C
E
R
E
N
O
V
A
T
I
O
N
TO
W
N
O
F
I
T
H
A
C
A
T
O
W
N
H
A
L
L
IT
H
A
C
A
,
N
Y
CL
I
E
N
T
P
R
O
J
E
C
T
N
O
:
A
A
1
6
2
0
.
5
1
7
SET NUMBER:
LOCATION MAP
PROJECT
LOCATION
TAITEM ENGINEERING
110 South Albany Street
Ithaca, New York 14850
Tel: 607.277.1118
PROJECT
NORTH
G
DISCIPLINE DESIGNATION
G = GENERAL
H = HAZARDOUS MATERIALS
AD = ARCHITECTURAL DEMOLITION
A = ARCHITECTURAL
PD = PLUMBING DEMOLITION
P = PLUMBING
MD = MECHANICAL DEMOLITION
M = MECHANICAL
ED = ELECTRICAL DEMOLITION
E = ELECTRICAL
FPD = FIRE PROTECTION DEMOLITION
FP = FIRE PROTECTION
SHEET TYPE
0 = GENERAL
1 = PLANS
2 = ELEVATIONS
3 = SECTIONS
4 = ENLARGED PLANS
5 = DETAILS
6 = WINDOWS
SHEET SEQUENCE NO.
-0 0 1SHEET NUMBER:
NUMBERING CONVENTION
DRAWING INDEX
NO.SHEET TITLE
GENERAL
G-001 COVER
G-101 CODE DATA, WIND UPLIFT DESIGN CRITERIA, AND GENERAL NOTES
HAZARDOUS MATERIALS C-CONTRACT
H-101 HAZARDOUS MATERIALS - ABATEMENT
ARCHITECTURAL
A-001 WALL TYPES AND SCHEDULES
AD-101 REMOVALS-FLOOR PLANS
AD-111 REMOVALS REFLECTED CEILING PLAN
AD-201 REMOVALS-INTERIOR ELEVATIONS
A-101 FLOOR PLANS
A-102 ATTIC FLOOR PLAN AND SECTION
A-111 REFLECTED CEILING PLANS
A-201 INTERIOR ELEVATIONS
A-301 WALL SECTIONS AND DETAILS
A-501 ENLARGED FLOOR PLAN, SECTION AND DETAILS
A-601 KEY PLAN AND ELEVATIONS
A-602 WINDOW ELEVATIONS
A-701 WINDOW AND DOOR DETAILS AND DOOR AND FRAME TYPES
PLUMBING
P-001 LEGENDS & NOTES
PD-101 PLUMBING DEMOLITION PLANS
P-101 PLUMBING FLOOR PLANS
FIRE PROTECTION
FP-001 LEGEND AND NOTES
FPD-101 SPRINKLER DEMOLITION PLANS
FP-101 SPINKLER FLOORS PLANS
MECHANICAL
M-001 LEGENDS & NOTES
MD-101 MECHANICAL DEMOLITION PLANS
M-101 MECHANICAL FLOOR PLANS
M-401 SCHEMATICS & DETAILS
ELECTRICAL
E-001 LEGENDS & NOTES
ED-101 ELECTRICAL DEMOLITION PLANS
E-101 ELECTRICAL FLOOR PLANS
E-102 ELECTRICAL FLOOR PLAN & SCHEMATIC
E-111 LIGHTING & FIRE ALARM FLOOR PLANS
E-601 PANEL SCHEDULES
1.CONTRACTOR PARKING:
1.1.ON-SITE CONTRACTOR PARKING IS NOT AVAILABLE.
1.2.CONTRACTOR PARKING IS AVAILABLE IN THE NEIGHBORING PARKING GARAGE.
PERMITS ARE AVAILABLE FOR PURCHASE FROM CITY OF ITHACA.
2.MATERIAL STAGING & LAYDOWN AREAS AND CRANE ACCESS LOCATIONS ARE INDICATED ON
THE DRAWINGS. THE CONTRACTOR SHALL COORDINATE FINAL CRANE STAGING
CONTRACTOR STAGING AREA, ACCESS, PARKING, DELIVERY & STORAGE WITH OWNER'S
REPRESENTATIVE PRIOR TO MOBILIZATION.
2.1.PROVIDE A CRANE PICK PLAN SUBMITTAL FOR REVIEW FOR ALL CRANE OPERATIONS.
INCLUDE CRANE LOADING INFORMATION, OPERATOR CERTIFICATIONS, LAYDOWN AND
PICK SITE PLAN FOR ARCHITECT AND OWNER REVIEW PRIOR TO WORK.
2.2.CONTRACTOR TO PROVIDE A FLAGMAN TO DIRECT TRAFFIC WHEN ACCEPTING MATERIAL
DELIVERIES OR EQUIPMENT MOVEMENT TO PROVIDE SAFE PASSAGE TO CONSTRUCTION
AREAS. TEMPORARY ROAD CLOSURES MUST BE COORDINATED IN ADVANCE. MAINTAIN
ROAD ACCESS WIDTH IN ACCORDANCE WITH LOCAL AND STATE REGULATIONS BUT NOT
LESS THAN 14'-0” WIDE.
2.3.ANY SIDEWALK OR ROAD CLOSURES MUST BE IN CONFORMANCE WITH THE CITY OF
ITHACA REQUIREMENTS AND REGULATIONS, AND ANY NECESSARY PERMITS MUST BE
OBTAINED IN ACCORDANCE WITH CITY OF ITHACA REGULATIONS.
3.CONTRACTOR SHALL BARRICADE, IN THE FORM OF A 6'-0” HIGH CHAIN LINK FENCE, THE
PERIMETER OF ALL STAGING AREAS TO PREVENT PUBLIC ACCESS. THE BARRICADE SHALL
HAVE A LOCKABLE 12'-0” WIDE DOUBLE GATE.
3.1.PROVIDE TEMPORARY WAYFINDING AND CONSTRUCTION CAUTION SIGNAGE TO DIRECT
PEDESTRIAN TRAFFIC AROUND BUILDING TO AVAILABLE ENTRANCES; SIGNAGE SIZE: 12”X
24”, COROPLAST BOARD OR OTHER APPROVED MATERIAL, MOUNTED TO TEMPORARY
CONSTRUCTION FENCE WITH HEAVY DUTY NYLON CABLE TIES THROUGH (4) EYELETS AT
CORNERS.
3.2.PROVIDE INTERIOR SIGNAGE AND THROUGHOUT THE BUILDING DIRECTING PEDESTRIAN
TRAFFIC AS NEEDED BASED ON TEMPORARY STAGING TO ALTERNATE EXIT LOCATIONS.
3.3.PROVIDE RUBBER PARKING WHEEL BLOCKS AT ALL ADJACENT PARKING SPACES
ABUTTING THE FENCING TO PROTECT FROM IMPACT.
3.4.PROVIDE FENCE SCREENING MOUNTED ON THE INSIDE OF THE FENCE AROUND THE
PERIMETER OF ALL STAGING AREAS AND TEMPORARY CONSTRUCTION FENCES.
COLOR GREEN VISIBILITY PERCENTAGE 85% OR MORE.
3.5.FENCE POSTS LOCATED IN GRASS AREAS MAY BE DRILLED. POSTS AND BASE OF
FENCE ON IMPERVIOUS SURFACES TO BE BALLASTED WITH OUTRIGGERS ADEQUATELY
DESIGNED TO WITHSTAND WIND LOADS FROM OVERTURNING THE FENCE. CALL UFPO DIG
SAFELY TO SURVEY AND MARK AREA FOR UTILITIES.
4.SITE PLAN INFORMATION IS BASED ON RECORD INFORMATION PROVIDED. NOT ALL EXISTING
UTILITIES, TREES, LANDSCAPING, SIDEWALKS, PAVEMENTS, EQUIPMENT, FIXTURES AND
TOPOGRAPHIC INFORMATION MAY BE SHOWN. CONTRACTOR SHALL FIELD VERIFY AND
FAMILIARIZE THEMSELVES WITH EXISTING CONDITIONS. REPAIR AND RESTORE ANY DAMAGE
TO EXISTING CONSTRUCTION AND SITE WORK RESULTING FROM THE WORK OF THIS PROJECT
INCLUDING BUT NOT LIMITED TO: GRASSED OR LANDSCAPED AREAS, CURBS, WALKWAYS,
CATCH BASINS, PAVEMENT, ETC. CAUSED BY THE WORK OF THIS PROJECT. REPAIRS ARE TO
MATCH ORIGINAL/ADJACENT SURFACES UNLESS NOTED OTHERWISE. CONTRACTOR TO TAKE
PHOTOGRAPHS OF SITE PRIOR TO START OF WORK AND SUBMIT TO OWNER'S
REPRESENTATIVE.
5.EXTERIOR EGRESS PATHS, WALKWAYS AND ENTRANCES SHALL REMAIN UNOBSTRUCTED AND
PROTECTED. REFER TO CONSTRUCTION SAFEGUARD NOTES ON G-101. PROVIDE ALTERNATE
CIRCULATION AS NEEDED TO ACCESS THE WORK.
SITE GENERAL NOTES:
PROJECT#: 716-23-002
BID DOCUMENTS
10/24/2025
Fax (315) 487 - 5947
Suite 201
Tel (315) 488 - 0377
215 Wyoming Street
info@bellandspina.com
www.bellandspina.com
Fax (585) 487 - 9532
Suite 200
Tel (585) 200 - 5038
1163 Pittsford-Victor Rd
Syracuse, NY 13204Pittsford, NY 14534
SCALE:1/64" = 1'-0"1 SITE PLAN
1.PEDESTRIANS AND EGRESS PATHWAYS INCLUDING THE ACCESSIBLE RAMP SHALL REMAIN
UNOBSTRUCTED AND PROTECTED DURING THE WORK.
2.CONFORMANCE WITH CHAPTER 15 - CONSTRUCTION SAFEGUARDS OF THE 2020 NYS EXISTING
BUILDING CODE AND CHAPTER 33 - SAFGUARDS DURING CONSTRUCTION OF THE 2020 NYS
BUILDING CODE CONVEYED IN SITE GENERAL NOTES AND IN THE SITE PLAN ON THIS SHEET
(1/COVER). CONTRACTOR MUST COMPLY WITH CHAPTERS 15 OF THE NYSBC, 33 OF THE NYSEBC,
AND 33 OF THE NYS FIRE CODE AT ALL TIMES AND IT IS THEIR RESPONSIBILITY TO ENSURE
COMPLIANCE. COMPLY WITH THE FOLLOWING MINIMUM REQUIREMENTS:
2.1. OSHA - OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION.
2.2.2020 BUILDING CODE OF NYS, CHAPTER 33 SAFEGUARDS DURING CONSTRUCTION
2.3.2020 EXISTING BUILDING CODE OF NYS, CHAPTER 15 CONSTRUCTION SAFEGUARDS.
2.4.2020 FIRE CODE OF NYS, CHAPTER 33 FIRE SAFETY DURING CONSTRUCTION AND DEMOLITION.
3.THE BUILDING WILL BE OCCUPIED DURING THE CONSTRUCTION PERIOD. PROVIDE OVERHEAD
PROTECTION AT ALL INGRESS/ EGRESS DOORS (ENTRANCES, OVERHEAD DOORS AND EXIT
DOORS) IN THE VICINITY OF THE WORK AREA AND MAINTAIN FOR THE DURATION OF THE WORK AS
FOLLOWS:
A.PROVIDE APPROPRIATE OVERHEAD SCAFFOLDING/BRIDGING FOR OCCUPANTS ENTERING AND
EXITING THE BUILDING TO PROTECT FROM FALLING DEBRIS DURING THE WORK. SUCH
SCAFFOLDING MAY ALSO DOUBLE FOR CONTRACTOR ACCESS TO THE WORK. STORAGE OF
MATERIALS ON SCAFFOLDING SHALL ONLY BE PERMITTED IF THE SYSTEM IS DESIGNED AND
ENGINEERED FOR MATERIAL STORAGE.
B.CONSTRUCT SYSTEM IN ACCORDANCE WITH NYS UNIFORM FIRE PREVENTION AND BUILDING CODE
AND OSHA REGULATIONS.
C.WHERE SUBJECT TO IMPACT FROM VEHICLES OR EQUIPMENT, PROVIDE BARRIERS TO PROTECT
THE SYSTEMS FROM IMPACT.
D.POST TEMPORARY SIGNAGE ON THE PROTECTION COMPONENTS INDICATING WORK IN
APPROPRIATE AREAS.
E.PROVIDE A MINIMUM 1 FOOTCANDLE (Fc) TEMPORARY CONSTRUCTION LIGHTING AT DOOR
LOCATIONS BELOW OVERHEAD PROTECTION SCAFFOLDING.
F.SUCH SYSTEMS SHALL BE PREPARED, DESIGNED AND STAMPED BY A NYS LICENSED
PROFESSIONAL ENGINEER AND SUBMITTED FOR REVIEW AND APPROVAL. COORDINATE ALL
WORK WITH THE OWNER. INCLUDE THE OVERHEAD PROTECTION SYSTEM AS PART OF THE
SUBMITTED SAFETY PLAN.
G.REPAIR/ RESTORE SYSTEM ANCHORAGE OR ATTACHMENT POINTS ON THE BUILDING.
2.PROVIDE TEMPORARY CONSTRUCTION BARRIERS AT OTHER AREAS AROUND THE WORK AREA TO
PROTECT PEDESTRIANS IN ACCORDANCE WITH THE FOLLOWING:
CONSTRUCTION SAFEGUARDS NOTES:
PROTECTION OF PEDESTRIANS
HEIGHT OF
CONSTRUCTION
DISTANCE OF CONSTRUCTION
TO LOT LINE OR WALKWAY
TYPE OF PROTECTION
REQUIRED
MORE THAN
8 FEET
LESS THAN 5 FEET
5 FEET OR MORE, BUT NOT MORE THAN
ONE-FOURTH THE HEIGHT OF CONSTRUCTION
5 FEET OR MORE, BUT BETWEEN ONE-FOURTH
AND ONE-HALF THE HEIGHT OF CONSTRUCTION
5 FEET OR MORE, BUT EXCEEDING
ONE-HALF THE HEIGHT OF CONSTRUCTION
BARRIER AND OVERHEAD
PROTECTION
BARRIER
NONE (FENCE)
PROVIDE OVERHEAD PROTECTION AT ENTRANCE/ EXIT COMPLYING WITH BCNYS CHAPTER
33 SAFEGUARDS DURING CONSTRUCTION AND EBCNYS CHAPTER 15 CONSTRUCTION
SAFEGUARDS.
BARRIER AND OVERHEAD
PROTECTION
1.THIS PROJECT IS DESIGNED IN ACCORDANCE WITH EXISTING 2020 BUILDING CODE
AND THE 2020 BUILDING CODE OF NEW YORK STATE (REFERENCING THE 2018
INTERNATIONAL CODES).
2.PER 2020 ECCNYS, C501.6 HISTORIC BUILDINGS: PROVISIONS OF THIS CODE
RELATING TO THE CONSTRUCTION, REPAIR, ALTERATION, RESTORATION AND
MOVEMENT OF STRUCTURES, AND CHANGE OF OCCUPANCY SHALL NOT BE
MANDATORY FOR HISTORIC BUILDINGS.
3.EXPOSED MATERIALS THAT WERE ANTICIPATED TO BE WITHIN THE SCOPE OF THIS
PROJECT AT THE TIME OF DESIGN HAVE BEEN TESTED FOR ASBESTOS AND LEAD
PAINT CONTENT. SEE THE HAZARDOUS MATERIAL SURVEY REPORT APPENDED TO THE
PROJECT MANUAL FOR A LIST OF TESTED MATERIALS. AND THEIR RESULTS. IN
SUMMARY, ACM MATERIALS & LEAD BASED MATERIALS ARE ANTICIPATED TO BE
DISTURBED.
4.THE SCOPE OF WORK GENERALLY INCLUDES THE FOLLOWING:
4.1.RESTORATION OF HISTORIC WINDOWS.
4.2.INTERIOR INSULATION AT EXTERIOR WALLS.
4.3.UPDATING PUBLIC RESTROOMS FOR ADA CONFORMANCE.
4.4.REMOVAL OF RESTROOM IN COURT CLERK AREA.
4.5.RECONFIGURATION AND HARDENING OF COURT CLERK ENTRANCE.
4.6.RENOVATION OF SECOND FLOOR MEZZANINE, INCLUDING RESTROOM.
4.7.INSULATING THE ATTIC.
4.8.UPDATED LIGHTING IN THE SPACES ABOVE.
4.9.UPDATED MECHANICAL IN THE SPACES ABOVE.
5.THE 1910 & 1935 PORTION OF THE BUILDING IS CONSIDERED HISTORICALLY
SIGNIFICANT AND IS LISTED WITH THE NATIONAL REGISTER. WINDOW MODIFICATIONS
HAVE BEEN SUBMITTED TO SHPO FOR APPROVAL.
5. WHAT IS REFEREED TO AS "THE MEZZANINE," IS NOT A TRUE MEZZANINE PER CODE. THE
TERM IS FOLLOWING THE ORIGINAL BUILDING DRAWINGS.
GENERAL DESIGN NOTES:
1000 Mi50200
C - CONTRACT
C - CONTRACT
P - CONTRACT
P - CONTRACT
H- CONTRACT
E - CONTRACT
ALL
REGISTRATION EXPIRES: 08/31/2028
105
CORRIDOR
3
STAIR
101
LOBBY
111
TOWN BOARD/COURTROOM
108
CORRIDOR
109
OFFICE
110
OFFICE
107
OFFICE
104
RESTROOM
103
RESTROOM
102
CORRIDOR
CABINET
M03
TENATE SPACE 2
M02
TENANT SPACE 1
M01
CORRIDOR
M02A
RESTROOM
BUILDING CODE SUMMARY DATA
BUILDING NAME AND LOCATION TOWN OF ITHACA TOWN HALL
215 NORTH TIOGA STREET
ITHACA, NY
COUNTY OF TOMPKINS
CODE REFERENCE 2020 NYS BUILDING CODE AND / OR 2020 NYS EXISTING BUILDING
CODE
ITEM (SECTION)EXISTING REQ.PROPOSED REMARKS
ALTERATION CLASSIFICATION TYPE
(EBCNYS CHAPTER 5)
LEVEL 2
USE & OCCUPANCY GROUP
(BCNYS CHAPTER 3)
B, A & S-1 N/C
SPRINKLERED YES N/C
CONSTRUCTION TYPE
(BCNYS CHAPTER 6)
II B N/C N/C
BUILDING HEIGHT
(BCNYS 504.3)
30'N/C N/C
BUILDING AREA
(BCNYS 506.2)
20,520 N/C N/C
BUILDING NO. STORIES
(BCNYS TBL 504.4)
2 N/C N/C
MIXED USE AND OCCUPANCIES
SEPARATION OF OCCUPANCIES
(BCNYS 508.4)
NON SEP N/C N/C
INCIDENTAL USES
(BCNYS 509)
N/C N/C N/C
ACCESSORY USE AREAS
(BCNYS 508.2)
N/C N/C N/C
SPECIAL USE & OCCUPANCY
(BCNYS CHAPTER 4)
N/A N/C N/C
MEANS OF EGRESS
(BCNYS CHAPTER 10)
N/C N/C N/C
ACCESSIBILITY
(BCNYS CHAPTER 11)
N/C N/C N/C
N/A - NOT APPLICABLE N/C - NO CHANGE N/R - NOT REQUIRED N/P - NOT PROVIDED
BUILDING CODE SUMMARY DATA
ITEM (SECTION)EXISTING REQ.PROPOSED REMARKS
TOTAL OCCUPANT LOAD
(BCNYS 1004)
10681 SF/150=71.2=
72 OCC (B)
2984 SF/15=198.9=
199 OCC (A)
13251 SF/300=44.17=
45 OCC (S-1)
N/C "2ND FLOOR" OCCUP.
LOAD = 6 PPL. OCCUP.
LOAD < 50, MEZZ. STAIR
WIDTH REQ'D = 36",
WIDTH EXISTING = 44"
EGRESS WIDTH
(BCNYS 1005.2)
N/C N/C N/C
EGRESS DOOR WIDTH
(EBCNYS 1005)
3'-0" MIN.N/C N/C
EXIT ACCESS TRAVEL
(BCNYS 1017)
113'--SEE 1 & 2/G-101
MIN CORRIDOR WIDTH
(BCNYS TBL 1020.2)
N/C N/C N/C
CORRIDOR FIRE RATING
(BCNYS TBL 1020.1)
N/C N/C N/C
MIN. NUMBER OF EXITS
(BCNYS TBL 1006.3.1)
3 --
ACCESSIBILITY
(CHAPTER 11)
NON-COMFORMING YES YES BATHROOM OFFICE
ACCESS
N/A - NOT APPLICABLE N/C - NO CHANGE N/R - NOT REQUIRED N/P - NOT PROVIDED
TO THE BEST OF THE REGISTERED DESIGN PROFESSIONALS KNOWLEDGE, BELIEF AND PROFESSIONAL
JUDGEMENT, THESE PLANS AND/OR SPECIFICATIONS ARE IN COMPLIANCE WITH THE 2020 UNIFORM CODE
ECCNYS COMPLIANCE DATA
COUNTY
CLIMATE ZONE
COMMERCIAL / RESIDENTIAL
TOMPKINS COUNTY
6
COMMERCIAL
COMPLIANCE METHOD
(IECC SECTION C401)
ECCNYS CHAPTER 4
ENVELOPE SCOPE OF WORK INSULATE EXTERIOR WALLS, RESTORE HISTORIC WINDOWS
ITEM (SECTION)EXISTING REQ.PROPOSED REMARKS
ROOF INSULATION
INSULATION ABOVE ROOF DECK NONE N/C N/C
ATTIC INSULATION N/C N/C R-25
WALLS ABOVE GRADE NONE N/C
WALLS BELOW GRADE NONE N/C N/C
FENESTRATION
VERTICAL FENESTRATION (MAX30%)N/C N/C N/C PER EXIST. BLDG ENERGY
U-FACTOR (FIXED)N/C 0.36 N/C
CODE, WE HAVE MADE A
GOOD FAITH TO MEET
U-FACTOR (OPERABLE)N/C 0.43 N/C
SHGC N/C 0.40 N/C
NYSBC BUT GIVEN THE
HISTORIC NATURE OF THE
BUILDING ALL MIN. MAY
NOT BE MET.AIR LEAKAGE N/C N/C N/C
VAPOR RETARDER N/C N/C YES
AIR BARRIER N/C N/C YES
N/A - NOT APPLICABLE N/C - NO CHANGE N/R - NOT REQUIRED N/P - NOT PROVIDED
TO THE BEST OF THE REGISTERED DESIGN PROFESSIONALS KNOWLEDGE, BELIEF AND PROFESSIONAL
JUDGEMENT, THESE PLANS AND/OR SPECIFICATIONS ARE IN COMPLIANCE WITH THE 2020 ENERGY
CONSERVATION CONSTRUCTION CODE OF NEW YORK STATE.
SHEET OF
SHEET NUMBER
SHEET TITLE
PROJECT NUMBER
PROJECT
NORTH
CONSULTANT
It is a violation of the New York State Education
Law, Article 145 Sec. 7209, for any person
unless he is acting under the direction of a
licensed professional Architect, Engineer or
Land Surveyor to alter an item in any way. If an
item bearing the seal of an Architect, Engineer
or Land Surveyor is altered, the altering
Architect, Engineer or Land Surveyor shall affix
to the item his seal and the notation "altered by"
followed by his signature and the date of such
alteration, and a specific description of the
alteration.
PROJECT
8/
7
/
2
0
2
3
9
:
4
0
:
4
6
A
M
Fax (315) 487 - 5947
Syracuse, NY 13204
Tel (315) 488 - 0377
215 Wyoming Street
info@bellandspina.com
www.bellandspina.com
Fax (585) 487 - 9532
Pittsford, NY 14534
Tel (585) 200 - 5038
1160-C Pittsford-Victor Rd
DATEMARK DESCRIPTION
The Contractor shall verify all dimensions and
notify the Architect in writing of any
discrepancies.
All drawings and specifications are the
property of the Architect and shall be used
only on the job designated.
CHECKED
SCALE
DRAWN
DATE
AS NOTED
CODE DATA, WIND
UPLIFT DESIGN
CRITERIA, AND
GENERAL NOTES
G-101
10/24/2025
HHV DE
716-23-002
TO
W
N
O
F
I
T
H
A
C
A
2
N
D
F
L
O
O
R
&
C
O
U
R
T
O
F
F
I
C
E
R
E
N
O
V
A
T
I
O
N
TO
W
N
O
F
I
T
H
A
C
A
T
O
W
N
H
A
L
L
21
5
N
O
R
T
H
T
I
O
G
A
S
T
R
E
E
T
IT
H
A
C
A
,
N
Y
Cl
i
e
n
t
P
r
o
j
e
c
t
N
o
:
A
A
1
6
2
0
.
5
1
7
312
BID DOCUMENTS
PLUMBING CODE SUMMARY DATA
ITEM (SECTION)PROPOSED REMARKS
TOWN OFFICES, COURT CLERK,
BASEMENT EMPLOYEE LOUNGE &
2ND FLOOR (B)
COURTROOM & LOBBY (A)
STORAGE (S-1)
10681 SF/150=71.2=
72 OCC
2984 SF/15=198.9=
199 OCC
13251 SF/300=44.17=
45 OCC
CLASSIFICATION WATER CLOSETS LAVATORIES
ASSEMBLY PUBLIC
FEMALE (100)
MALE (100)
100 OCC/65=1.5
100 OCC/125=0.8
100 OCC/200=0.5
100 OCC/200=0.5
WC<6; UNISEX NOT REQ.
BUSINESS EMPLOYEE
FEMALE (36)
MALE (36)
36 OCC/25=1.44
36 OCC/25=1.44
36 OCC/40=0.9
36 OCC/40=0.9
STORAGE EMPLOYEE
FEMALE (23)
MALE (23)
23 OCC/100=0.23
23 OCC/100=0.23
23 OCC/100=0.23
23 OCC/100=0.23
TOTAL
F: 3.17= 4 WC (2
PUBLIC AND 2 EMP)
M:2.47= 3 WC (1
PUBLIC, 2 EMPLOYEE)
F: 1.63= 2 LAV
M: 1.63= 2 LAV
U: 5 WC/5 LAV [1 PUB; 4 EMP.]
F: 2 WC/1 LAV [PUB.]
M: 2 WC/ 1 LAV. [PUB.]
ADDITIONAL
ABANDONED FIXTURES IN
BASEMENT
N/A - NOT APPLICABLE N/C - NO CHANGE N/R - NOT REQUIRED N/P - NOT PROVIDED
TO THE BEST OF THE REGISTERED DESIGN PROFESSIONALS KNOWLEDGE, BELIEF AND PROFESSIONAL JUDGEMENT, THESE PLANS AND/OR
SPECIFICATIONS ARE IN COMPLIANCE WITH THE 2020 UNIFORM CODE
NYS COURT FACILITIES - PART 34 SUMMARY
SECTION GUIDELINE PROPOSED REMARKS
VI: DESIGN GUIDELINES FOR
SECURITY
VI: DOORS AND WINDOWS
THE DESIGN OF WINDOWS AND DOORS SHOULD DETER ACCESS WITHOUT COMPROMISING AESTHETIC,
NATURAL LIGHT AND VIEW CONSIDERATIONS. THE USE OF BETTER COMPONENTS AT SOMEWHAT HIGHER
INITIAL COST SHOULD BE CONSIDERED IN ORDER TO PROVIDE BETTER SECURITY THAN AFFORDED BY
TRADITIONAL WINDOWS, DOORS, LOCKS & KEYS. THE USE OF IMPACT-RESISTANT GLASS OR PLASTIC
MATERIAL SHOULD BE CONSIDERED IN STRATEGIC LOCATIONS.
EXTERIOR WINDOWS: IMPACT
RESISTANT GLAZING. INTERIOR
TRANSACTION AREA: LEVEL 3
BALLISTIC RATING
IX: JUDGE'S FACILITIES IX 1: JUDGE'S CHAMBERS
The Judge's chambers should have:
- a private office (200 sf)
- a private restroom or access to a private judges' restroom
- space in the office
- Immediate access to the secretary and any law clerk
- privacy both as to sound and vision
- RETAIN 2 JUDGE'S OFFICES
(APPROX. 110 SF)
- REMOVE EXISTING PRIVATE
RESTROOM PER OWNERS REQUEST
JUDGE TO HAVE
ACCESS TO
EMPLOYEE ONLY
RESTROOM
IX 3: LAW CLER'S OFFICE (150 SF MINIMUM)
THE JUDGE'S LAW CLERK SHOULD HAVE A PRIVATE OFFICE TIHW WORK AREA AND SHELVING FOR A
WORKING LAW LIBRARY. THE LAW CLERK SHOULD HAVE EASY ACCESS TO THE JUDGE.
- SPACE GAINED FROM RESTROOM
REMOVAL ADDED TO CLERK OFFICE
(APPROX. 56 SF)
XI: CLERICAL FACILITIES XI 1: CLERK'S OFFICE
THE CLERK'S OFFICE SHOULD INCLUDE:
A PUBLIC AREA FOR WAITING/RECEPTION (20 SF/PER; 100 SF MIN)
- A PUBLIC COUNTER
- A CASHIER'S STATION WITH ADEQUATE SECURITY
- A TABLE FOR PUBLIC USE
- SEATS FOR WAITING
- COIN-OPERATED COPYING MACHINE FOR PUBLIC USE
- DISPLAY BOARDS
- PUBLIC RECORDS ACCESS AREA
GENERAL OFFICE AREA BEHIND COUNTER WITH NO PUBLIC ACCESS
- WORKING DESKS (85-95 SF/EMPLOYEE)
- RECORD FILES FOR CURRENT WORK
- ELECTRONIC DATA PROCESSING EQUIPMENT, IF NECESSARY
PRIVATE AREAS
- OFFICES FOR CHIEF CLERK AND ASSISTANTS
- CONFERENCE ROOM (20 SF/PER)
- RECORDS STORAGE AREA
- MAIL, SUPPLY , PHOTOCOPYING AND GENERAL SUPPLIES AREA
- VAULT OR SAFE FOR STORAGE OF CASH, IMPORTANT RECORDS OR EVIDENCE
STAFF FACILITIES AS REQ. BY LAW PER XI.2 TABLE 5
N/C
WALL RELOCATED
140 SF/EMPLOYEE
N/C
N/C
XIV: FACILITIES FOR THE PUBLIC XIV.2: PUBLIC RESTROOMS MALE/FEMALE
AS PER BUILDING CODE
RESTROOMS FOR PUBLIC USE SHOULD BE LOCATED CLOSE TO PUBLIC WAITING AREAS AND CLEARLY
MARKED
N/C
ADDITIONAL SUPPORT STAFF NOT AFFECTED BY SCOPE OF WORK
ITHACA ENERGY CODE SUPPLEMENT COMPLIANCE DATA
The requirements of this Ithaca Energy Code Supplement shall apply to the following construction:
1) All new construction, excluding additions and renovations that are not specified in this list
2) All additions 500 square feet or larger to single family dwellings or two-family dwellings
3) All additions 1,000 square feet or larger to buildings other than single family dwellings or two-
family dwellings
4) All MAJOR RENOVATIONS, as defined below:
Any construction or renovation to an existing structure other than a repair or addition, where
(A) the WORK AREA exceeds 75 percent of the FLOOR AREA and
(B) two or more of the following occur:
i) Replacement or new installation of a heating plant or system (e.g. boiler, furnace, or other major
system). Changes to ventilation and air conditioning systems are not considered renovations of
the heating system.
ii) Construction that involves disassembly of greater than 50% of the area of the above-grade
portion(s) of the BUILDING THERMAL ENVELOPE in the building.
iii) Changes to lighting, including but not limited to new installation, replacement, relocation, or
removal, of lamps, lighting, or other illumination fixtures in greater than 50% of the building
FLOOR AREA. Space within a building interior that is not currently lit, and is not proposed to be
lit, shall not count toward the 50% calculation
1) N/A
2) N/A
3) N/A
4A) <75%
4Bi) N/A
4Bii) <50%
4Biii) <50%
N/A - NOT APPLICABLE N/C - NO CHANGE N/R - NOT REQUIRED N/P - NOT PROVIDED
TO THE BEST OF THE REGISTERED DESIGN PROFESSIONALS KNOWLEDGE, BELIEF AND PROFESSIONAL JUDGEMENT, THESE PLANS AND/OR SPECIFICATIONS ARE IN COMPLIANCE WITH THE 2020 ENERGY CONSERVATION CONSTRUCTION CODE OF NEW YORK
STATE.
SCALE:1/8" = 1'-0"2 FIRST FLOOR EGRESS PLAN
SCALE:1/8" = 1'-0"1 2ND FLOOR EGRESS PLAN
90'
EXIT
113'
PER THE THRESHOLDS, THE IEC SUPPLEMENT IN NOT REQIRED
R-8.4 AND
R-14.7
REGISTRATION EXPIRES: 08/31/2028
106
RESTROOM
104
RESTROOM
103
RESTROOM
102
CORRIDOR
105
CORRIDOR
3
STAIR
101
LOBBY
111
TOWN BOARD/COURTROOM
108
CORRIDOR
109
OFFICE
110
OFFICE
107
OFFICE
GENERAL NOTES:
1.ALL SURFACES BEHIND ANY
FURRED WALLS ARE
ASSUMED TO BE LBP
2.REFER TO DEMO ELEVATIONS
FOR EXTENT OF SCOPE
3.WINDOW PAINT ASSUMED TO
BE LBP
ACM WINDOW GLAZING
M02A
RESTROOM
M01
CORRIDOR
M03
TENATE SPACE 2
M02
TENANT SPACE 1
ACM VCT, TO REMAIN.
TO BE ENCAPSULATED
BY CARPET
ACM WINDOW GLAZING
GENERAL NOTES:
1.ALL STRUCTURAL STEEL IN
THE 2ND FLOOR & ATTIC HAS
LEAD-BASED PAINT
2.ALL CEILINGS OF 2ND FLOOR
HAVE LEAD-BASED PAINT
3.SCRAPE AND PREP ALL
SURFACES ON THE 2ND
FLOOR, WOOD TRIM, DOORS,
CASING ARE ASSUMED TO BE
LBP. TYP.
4.REFER TO DEMO ELEVATIONS
FOR EXTENT OF SCOPE
5.WINDOWS PAINT ASSUMED TO
BE LBP
EXISTING MECHANICAL.
SEE M-SERIES DWG.
REMOVE ASSUMED
ACM INSULATION
AND TWO SAWN
ABANDONED PIPES.
STRIP PAINT FROM HANDRAIL
MOUNTING BRACKETS.
THIS GROUP OF
PIPES TO REMAIN
STRIP PAINT FROM
ALL DOOR HINGES
AND HARDWARE.,
TYP.
REMOVE SHELVING
REQIURED TO ACCESS
PIPE
SHEET OF
SHEET NUMBER
SHEET TITLE
PROJECT NUMBER
PROJECT
NORTH
CONSULTANT
It is a violation of the New York State Education
Law, Article 145 Sec. 7209, for any person
unless he is acting under the direction of a
licensed professional Architect, Engineer or
Land Surveyor to alter an item in any way. If an
item bearing the seal of an Architect, Engineer
or Land Surveyor is altered, the altering
Architect, Engineer or Land Surveyor shall affix
to the item his seal and the notation "altered by"
followed by his signature and the date of such
alteration, and a specific description of the
alteration.
PROJECT
11
/
7
/
2
0
2
5
1
1
:
4
5
:
2
1
A
M
/HE
A
T
H
E
R
V
E
N
D
I
T
T
I
Fax (315) 487 - 5947
Syracuse, NY 13204
Tel (315) 488 - 0377
215 Wyoming Street
info@bellandspina.com
www.bellandspina.com
Fax (585) 487 - 9532
Pittsford, NY 14534
Tel (585) 200 - 5038
1160-C Pittsford-Victor Rd
DATEMARK DESCRIPTION
The Contractor shall verify all dimensions and
notify the Architect in writing of any
discrepancies.
All drawings and specifications are the
property of the Architect and shall be used
only on the job designated.
CHECKED
SCALE
DRAWN
DATE
AS NOTED
HAZARDOUS
MATERIALS -
ABATEMENT
H-101
10/24/2025
HHV,DE DE
716-23-002
TO
W
N
O
F
I
T
H
A
C
A
2
N
D
F
L
O
O
R
&
C
O
U
R
T
O
F
F
I
C
E
R
E
N
O
V
A
T
I
O
N
TO
W
N
O
F
I
T
H
A
C
A
T
O
W
N
H
A
L
L
21
5
N
O
R
T
H
T
I
O
G
A
S
T
R
E
E
T
IT
H
A
C
A
,
N
Y
Cl
i
e
n
t
P
r
o
j
e
c
t
N
o
:
A
A
1
6
2
0
.
5
1
7
313
BID DOCUMENTS
SCALE:1/4" = 1'-0"2 HAZARDOUS MATERIAL REMOVALS - FIRST FLOOR
SCALE:1/4" = 1'-0"1 HAZARDOUS MATERIALS REMOVALS - 2ND FLOOR
SCALE:1/32" = 1'-0"3 KEY PLAN
HAZARDOUS MATERIAL ABATEMENT NOTES: GENERAL
1.THE DRAWINGS ARE A GRAPHIC REPRESENTATION OF AREAS THAT HAZARDOUS
MATERIALS ARE TO BE ABATED. THE LOCATIONS AND APPROXIMATE QUANTITIES ARE
BASED ON VISUAL OBSERVATIONS, SAMPLING AND TESTING. TESTING REPORTS CAN
BE FOUND IN THE PROJECT MANUAL.
2.ABATEMENT OF AREAS/MATERIALS SHOWN ARE IDENTIFIED IN THE LEGEND.
3.LOCATIONS AND QUANTITIES INDICATED ON THE CONTRACT DOCUMENTS TAKE
PRECEDENCE OVER THE QUANTITIES INDICATED IN THE REPORTS FOUND IN THE
PROJECT MANUAL.
4.IF ADDITIONAL SUSPECT MATERIALS ARE DISCOVERED AND/OR DISTURBED, NOTIFY
THE ARCHITECT SITE REPRESENTATIVE IMMEDIATELY. THE ON-SITE PROJECT
MONITORING FIRM WILL BE RESPONSIBLE FOR SAMPLING.
5.CONTRACTOR SHALL RESTORE/REPAIR AND/OR REPLACE ANY DAMAGE TO ANY
AREA OR BUILDING FINISHES AS A RESULT OF TEMPORARY PROTECTION REQUIRED
FOR ABATEMENT.
6.THE OWNER SHALL PROCURE A NYSDOL CERTIFIED PROJECT MONITOR WHO WILL
HAVE THE AUTHORITY TO HALT THE WORK IF SUCH WORK IS NOT BEING CONDUCTED IN
ACCORDANCE WITH THE CONTRACT DOCUMENTS/VARIANCES OR LOCAL, STATE,
FEDERAL, RULES, REGULATIONS OR GUIDELINES.
7.COORDINATE THE LOCATION OF ANY REMOTE PERSONNEL AND/OR
DECONTAMINATION UNIT, SITE STORAGE OF MATERIAL, EQUIPMENT, WASTE
TRAILER/DUMPSTER WITH THE OWNERS SITE REPRESENTATIVE.
8.ALL ON-SITE HAZARDOUS MATERIALS ARE TO BE STORED IN A LOCKABLE CONTAINER.
ALL REGULATED HAZMAT MATERIAL IS TO HAVE A MANIFEST SIGNED BY THE OWNER'S
REPRESENTATIVE PRIOR TO LEAVING THE SITE. A COPY OF THE PROCESSED
MANIFEST MUST BE RETURNED TO THE OWNER AND PROJECT MONITOR WITHIN THIRTY
(30) DAYS.
9.WORK SHALL BE CONDUCTED IN CONFORMANCE WITH THE FOLLOWING CODES AND
REGULATIONS:
1.A.PART 56 OF TITLE 12 OF THE OFFICIAL COMPILATION OF CODES, RULE AND
REGULATIONS OF THE STATE OF NEW YORK (CITED AS 12 NYCRR PART 56)
1.B.CODE OF FEDERAL REGULATIONS 29 CFR 1926.1101 CONSTRUCTION STANDARD
FOR ASBESTOS - OSHA
1.C.CODE OF FEDERAL REGULATIONS 29 CFR 1926.59 & 1910.1200 HAZARD
COMMUNICATION STANDARD - OSHA
1.D.CODE OF FEDERAL REGULATIONS 40 CFR 763 SUBPART F - EPA AHERA
1.E.CODE OF FEDERAL REGULATIONS 49 CFR SUBPART M NATIONAL EMISSION
STANDARD FOR ASBESTOS - NESHAPS
HAZARDOUS MATERIAL ABATEMENT NOTES: EXTERIOR SEALANTS
1.THE ABATEMENT CONTRACTOR SHALL BE RESPONSIBLE TO ENSURE THE PERIMETER
GROUND IS FREE OF ALL CAULKING AND GLAZING DEBRIS AT THE END OF
ABATEMENT.
2.ENSURE THAT ALL SEALANT IS REMOVED FROM MASONRY MATERIAL (BRICK, STONE,
CONCRETE BLOCK, PRECAST) AND FRAMES.
3.REMOVE EXTERIOR AND INTERIOR SEALANTS OF OPENING.
4.PROPERLY PROTECT THE ENCLOSURE ASSEMBLY FROM WEATHER, AND ENTRY.
5.PCB-CONTAINING ABATED SEALANT IS TO HAVE A DISTINCT WASTE STREAM PATH
FROM ASBESTOS CONTAINING SEALANT.
6.MASONRY MATERIALS TO REMAIN THAT HAVE HAD PCB CONTAINING SEALANTS
ABATED ARE TO RECEIVE A PRIME COAT OF EPOXY PAINT TO PREVENT MIGRATION
OF PCB'S BACK INTO NEW SEALANT JOINT. SEE PAINTING SPECIFICATION 09 90 00.
ASBESTOS ABATEMENT NOTES: INTERIOR
1.ADDITIONAL ACM, LBP, AND/OR PCB MATERIALS MAY BE PRESENT IN WALL, CEILING
AND FLOOR CAVITIES THAT WHERE NOT ACCESSIBLE DURING SAMPLING.
2.CONTAINMENT AND WORK AREA LOCATIONS ARE TO BE SELECTED AND SIZED BY THE
CONTRACTOR AND SHALL BE SEQUENCED IN ALIGNMENT WITH THE PROJECT PHASING
REQUIREMENTS.
3.COORDINATE WITH ALL TRADES REGARDING ELECTRICAL, HVAC, AND PLUMBING
SHUTDOWNS/LOCK-OUTS NEEDED TO CONDUCT ABATEMENT.
4.ALL DEMOLITION NECESSARY TO ACCESS HAZARDOUS MATERIALS FOR REMOVAL
MUST BE CONDUCTED WITHIN A NEGATIVE PRESSURE ENCLOSURE. DEMOLITION DEBRIS
MAY BE DISPOSED OF AS CONDUCTION DEBRIS PROVIDED THE PROJECT MONITOR
DETERMINES THAT IT IS NOT CONTAMINATED AND THERE HAS BEEN NO DISTURBANCE
WITH THE ENCLOSURE. IF THE DEMOLITION DEBRIS IS DETERMINED TO BE
CONTAMINATED OR ACM WITHIN THE ENCLOSURE HAS BEEN DISTURBED, IT MUST BE
DISPOSED OF AS ASBESTOS WASTE.
5.ATTACHED ITEMS THAT PENETRATE ACM MATERIALS ARE TO BE REMOVED UNDER
CONTAINMENT.
LEAD NOTES:
1.ASSUME LEAD-BASED PAINT (LBP) EXISTS THROUGHOUT THE FACILITY. IMPLEMENT
LEAD-SAFE PRACTICES IN COMPLIANCE WITH ALL LOCAL, STATE, FEDERAL
REGULATIONS AND RECOMMENDATIONS.
LEGEND:
ACM = ASBESTOS CONTAINING MATERIAL
VAT = VINYL ASBESTOS FLOOR TILE
PCB = POLYCHLORINATED BIPHENYLS
LBP = LEAD BASED PAINT
LF = LINEAL FEET
SF = SQUARE FEET
REGISTRATION EXPIRES: 08/31/2028
ROOM FINISH SCHEDULE
SPACE FLOOR BASE CEILING
GENERAL REMARKSROOMDOOR
MARK MATERIAL FINISH COLOR MATERIAL FINISH COLOR MATERIAL FINISH COLOR MATERIAL HEIGHT FINISH COLOR
102 EXIST.--EXIST./TILE -EXISTING P-1 P-1 ALIGN NEW PARTITION WITH EXIST. PROVIDE SMOOTH TRANSITION
103 -EXIST/TILE -EXIST./TILE -EXIST. GWB/FRP PAINT P-1/FRP-1 EXIST./GWB ±9'-0"/12'-0"PAINT -
104 104-1 EXIST./TILE -EXIST./TILE -PAINT P-1/FRP-1 EXIST./GWB REINSTALL EXISTING DOOR
105 105-1 CARPET -C1 VINYL -V1 EXISTING GWB -
107 107-1 CARPET ---
108 ----
109 ----
110 ----
3 3-1 ---
M01 ---P-3 -
M02 MO2-1 --
MO2A MO2A-1 ---
MO3 ---
-
±9'-0"/12'-0"PAINT
NORTH
MATERIAL FINISH COLOR
SOUTH
WALLS
MATERIAL FINISH COLOR
EAST
MATERIAL FINISH COLOR
WEST
PAINT EXISTING/GWB EXISTING/GWB EXISTINGPAINTPAINT
EXISTING/FRP PAINT EXISTING/FRP PAINT GWB/FRP PAINT
PAINT
GWB/FRP PAINT EXIST. GWB/FRP PAINT GWB/FRP-1 PAINT
EXIST./ GWB EXISTINGPAINTP-1 PAINT PAINT PAINT
EXIST./GWB GWB EXISTING EXISTINGPAINTP-1 PAINT PAINT PAINT
EXISTING EXISTING EXISTING EXISTINGPAINTP-1 PAINT PAINT PAINTCARPET
EXISTING GWB EXISTING EXISTINGPAINTP-1 PAINT PAINT PAINT
EXISTING GWB EXISTING EXISTINGPAINTP-1 PAINT PAINT PAINT
EXISTING EXISTING EXISTING EXISTINGPAINTP-1 PAINT PAINT PAINT
CARPET
CARPET
CARPET
CARPET
CARPET
EXISTING
EXISTING CLEAN TREADS
EXISTING EXISTING
EXISTING/GWB GWB EXIST./GWB GWB
PAINT P-2 PAINT PAINT PAINT
PAINT P-2 PAINT PAINT PAINT
VINYL
VINYL
VINYL
VINYL
CLEAN AND POLISH EXISTING TERRAZZO AND MARBLE FLOOR.EXIST./TILE EXIST./TILE EXIST./TILE EXIST./TILEP-2/T-1PAINT PAINT PAINT PAINT
EXISTING GWB EXIST./GWB EXISTINGPAINTP-2PAINT PAINT PAINT
EXIST./WOOD
EXIST./WOOD
TILE
EXIST./WOOD
MATCH EXIST.
T-3
EXIST./GWB ±8'-8"
EXIST./GWB PAINT
C1
C1
C1
C1
C2
C2
C2
V1
V1
V1
V1
EXIST./GWB PAINT
EXIST./GWB PAINT
EXIST./ACT
EXIST./ACT
EXISTING PAINT
EXISTING EXISTING EXISTING PAINT
EXISTING PAINT
EXISTING PAINT
±9'-0"/12'-0"
±9'-0"/12'-0"
±9'-0"/12'-0"
±9'-0"/12'-0"
±9'-0"/12'-0"
±8'-0"
±8'-0"
±8'-0"
±9'-0"
±8'-0"EXISTING
P-3
T-1
P-3
P-1
P-1/FRP-1
P-1/FRP-1
P-1
P-1
P-1
P-1
P-1
P-1
P-2
P-2
P-2/T-1
P-2
P-1
P-1/FRP-1
P-1/FRP-1
P-1
P-1
P-1
P-1
P-1
P-1
P-2
P-2
P-2/T-1
P-2
P-1
P-1/FRP-1
P-1/FRP-1
P-1
P-1
P-1
P-1
P-1
P-1
P-2
P-2
P-2/T-1
P-2
P-1
P-1
P-1
P-1
P-1
ACT-1
ACT-1
P-1
P-5
P-5
P-5
PAINT P-5
T-3
T-3
T-3 EXIST. GWB/FRP
WINDOW
TRIM
P-1
P-1
P-1
P-1
P-1
P-1
P-1
P-1
P-4
P-3
P-3
P-3
P-3
PAINT
4
1
4"
PLAN
SECTION
℄℄1'-4"
REUSE 3 5 8 LIGHT GAUGE METAL
FRAMING 16" O.C.
5 8" TYPE X GWB
MINERAL WOOL
INSULATION
VAPOR RETARDER
SECTION
41
4"
PLAN
SECTION
℄℄1'-4"
02 0604
±6
3
4"
V
.
I
.
F
.
PLAN
SECTION
℄℄1'-4"
05
2
5
/
8
"
PLAN
SECTION
2" HAT CHANNEL
5 8" TYPE X GWB,
PAINT
INSULATION
VAPOR
RETARDER
01
4
1
4"
PLAN
SECTION
℄℄1'-4"
3 5 8 LIGHT GAUGE METAL
FRAMING 16" O.C.
5 8" TYPE X GWB
MINERAL WOOL
INSULATION
VAPOR RETARDER
03
EXISTING
MASONRY
WALL
47
8"
℄℄1'-4"
3 5 8 LIGHT GAUGE METAL
FRAMING 16" O.C.
MINERAL WOOL
INSULATION
ALIGN WITH EXISTING WALL
FOR A SMOOTH TRANSITION
±7
"
V
.
I
.
F
.
±7
"
V
.
I
.
F
.
PLAN
SECTION 07
47
8"
℄℄1'-4"
5 1 2" LIGHT GAUGE METAL
FRAMING 16" O.C.
3 5 8 LIGHT GAUGE METAL
FRAMING 16" O.C.
MINERAL WOOL
INSULATION
3 5 8 SHAFT WALL
FRAMING 16" O.C.
MINERAL WOOL
INSULATION
MINERAL WOOL
INSULATION
5 8" TYPE X
GWB,
PAINT
SECTION 08
PLAN
EXISTING
MASONRY
WALL
5 8" TYPE X
GWB,
PAINT
1/2" FIBERGLASS
BALLISTIC MATERIAL
CARRY TO CEILING
PLAN
EXISTING
MASONRY
WALL
EXISTING
MASONRY
WALL
R-8.5 R-14.7 R-14.7
EXISTING
WALL
1/2" FIBERGLASS
BALLISTIC
MATERIAL
CARRY TO
CEILING
VINYL
BASE
5 8" TYPE X GWB
MINERAL WOOL
INSULATION
VAPOR RETARDER
EXISTING MASONRY
WALL
REUSE 3 5 8 LIGHT
GAUGE METAL
FRAMING 16" O.C.
TILE BASE
MATCH EXISTING
SEAL VAPOR
RETARDER
TO FLOOR
3 5 8 SHAFT WALL
FRAMING 16" O.C.
5 8" TYPE X GWB
MINERAL WOOL
INSULATION
5 8" TYPE X GWB
VAPOR RETARDER
EXISTING MASONRY
WALL
TILE BASE
MATCH EXISTING
SEAL VAPOR
RETARDER
TO FLOOR
2" HAT CHANNEL
MINERAL WOOL
INSULATION
5 8" TYPE X GWB
MINERAL WOOL
INSULATION
VAPOR RETARDER
EXISTING MASONRY
WALL
3 5 8 LIGHT GAUGE METAL
FRAMING 16" O.C.
SEAL VAPOR
RETARDER
TO FLOOR
3 5 8 LIGHT GAUGE METAL
FRAMING 16" O.C.
5 8" TYPE X GWB,
PAINT
TILE BASE
WOOD BASE
MATCH EXISTING,
PAINTBASE VARIES SEE
SCHED.
WOOD BASE
MATCH EXISTING,
PAINT
5 12" LIGHT GAUGE METAL
FRAMING 16" O.C.
MINERAL WOOL
INSULATION
TILE WAINSCOT
MINERAL WOOL
INSULATION
5 8" TYPE X GWB,
PAINT
5 8" TYPE X GWB,
PAINT
3 5 8 LIGHT GAUGE
METAL FRAMING 16"
O.C.
5 8" TYPE X GWB,
PAINT
VINYL BASE
MINERAL WOOL
INSULATION
1/2" FIBERGLASS
BALLISTIC MATERIAL
CARRY TO CEILING
URINAL
WATER CLOSET
(UR.)
(W.C.)LAVATORY
(LAV.)
CLOSET (W.C.)
1'-6"
1'
-
5
"
3'-0"
1'-0"
8"
1'
-
6
"
1'-0"3'-6"
3'
-
3
"
3'-4"
1'
-
5
"
2'
-
1
0
"
3'
-
0
"
3'
-
0
"
GRAB BAR
(G.B.)
PAPER TOWEL
(PTD)
MIRROR
(T
.
T
.
D
.
)
SOAP DISPENSER
TO
I
L
E
T
T
I
S
S
U
E
D
I
S
P
E
N
S
E
R
(SD.)
44
"
-
4
8
"
3'
-
4
"
OV
E
R
C
O
U
N
T
E
R
O
R
L
A
V
.
35
"
M
A
X
I
F
N
O
T
O
V
E
R
CO
U
N
T
E
R
O
R
L
A
V
44
"
-
4
8
"
2'
-
0
"
CE
N
T
E
R
O
F
V
A
L
V
E
DISPENSER
WATER
TI
L
E
O
R
F
R
P
W
A
I
N
S
C
O
T
4'
-
0
"
M
I
N
.
DOOR SCHEDULE
MARK
FRAME DOOR
FRAME
FINISH
DOOR
UNDERCUT
DOOR/
TRIM
FINISH
HARDWARE
GENERAL REMARKSWIDTHHEIGHTMATERIALTYPEWIDTHHEIGHTTHICKNESSMATERIALTYPESET NO.KEYSIDE
ROOM NO.
104-1 EXISTING EXISTINGPAINT, P-4 -PAINT, P-4 EXIST.102
REINSTALL SALVAGED DOOR, PATCH AND REPAIR HM FRAME, PAINT
105-1 3'-4"7'-2"HM 1 3'-0"7'-0"1 3 4"WOOD A -CLEAR
FINISH
(D)/PAINT,
P-4 (T)
1
107-1 3'-0"7'-0"HM BPAINT, P-4 -PAINT, P-4 102
C PAINT, P-4
M02-1
2'-6"7'-0"
-
HM
2" UNDERCUTM02A-1 EXISTING EXISTING REINSTALL SALVAGED DOOR. MATCH TRIM IN KIND
EXISTING EXISTING EXISTING
3'-4"7'-2"HM 1 BULLET RESISTANT LEVEL 3 RATED. FOB PROVIDED AND INSTALLED
BY OWNER. ELECTRIC STRIKE BY OTHERS, ELECTRICIAN TO INSTALL
22-6 AND 18-4 STANDARD WIRE FROM IT ROOM TO STRIKE PLATE.
ADA OPENER SEE E SERIES
HM 12'-10"7'-2"
EXISTINGEXISTINGEXISTINGEXISTING
±2'-8" V.I.F.EXISTING EXISTING EXISTING±6'-10" V.I.F.
HEAD JAMB
2/A-701 6/A-701
3/A-701 7/A-701
M02-2
M03-1
2" UNDERCUTEXISTINGEXISTINGEXISTINGEXISTINGEXISTINGEXISTINGEXISTINGEXISTINGEXISTING
1 3 4"
LOUVERED BASE
3-1
2" UNDERCUTEXISTINGEXISTINGEXISTINGEXISTINGEXISTINGEXISTINGEXISTINGEXISTINGEXISTING
ELECTRIC STRIKE BY OTHERS, ELECTRICIAN TO INSTALL 22-6
AND 18-4 STANDARD WIRE FROM IT ROOM TO STRIKE PLATE.
1 3 4"
105
EXISTINGWOOD
2
3
4
5
7
6
FOB PROVIDED AND INSTALLED BY OWNER. ELECTRIC STRIKE BY
OTHERS, ELECTRICIAN TO INSTALL 22-6 AND 18-4 STANDARD WIRE
FROM IT ROOM TO STRIKE PLATE
3'-4"7'-2"3'-0"7'-0"1 3 4"WOOD APAINT, P-4
M01
M02
M01
M01
101
EXISTINGEXISTING
PAINT, P-3
PAINT, P-3
PAINT, P-3
PAINT, P-3
PAINT, P-3
PAINT, P-3
PAINT, P-3
PAINT, P-4
-
4/A-701 8/A-701
5/A-701 9/A-701
CLEAR
FINISH
(D)/PAINT,
P-4 (T)
103-1 EXISTING EXISTINGPAINT, P-4 PAINT, P-4 EXIST.102EXISTINGEXISTINGEXISTINGEXISTINGEXISTINGEXISTINGEXISTING
REINSTALL SALVAGED DOOR, PATCH AND REPAIR HM FRAME, PAINT
M01-1 -EXISTING EXISTINGEXISTINGEXISTINGEXISTINGEXISTINGEXISTINGEXISTINGEXISTING EXIST.M01PAINT, P-3PAINT, P-3
SHEET OF
SHEET NUMBER
SHEET TITLE
PROJECT NUMBER
PROJECT
NORTH
CONSULTANT
It is a violation of the New York State Education
Law, Article 145 Sec. 7209, for any person
unless he is acting under the direction of a
licensed professional Architect, Engineer or
Land Surveyor to alter an item in any way. If an
item bearing the seal of an Architect, Engineer
or Land Surveyor is altered, the altering
Architect, Engineer or Land Surveyor shall affix
to the item his seal and the notation "altered by"
followed by his signature and the date of such
alteration, and a specific description of the
alteration.
PROJECT
11
/
7
/
2
0
2
5
1
1
:
4
5
:
4
1
A
M
/HE
A
T
H
E
R
V
E
N
D
I
T
T
I
Fax (315) 487 - 5947
Tel (315) 488 - 0377
215 Wyoming Street
info@bellandspina.com
www.bellandspina.com
Fax (585) 487 - 9532
Suite 200
Tel (585) 200 - 5038
1163 Pittsford-Victor Rd
DATEMARK DESCRIPTION
The Contractor shall verify all dimensions and
notify the Architect in writing of any
discrepancies.
All drawings and specifications are the
property of the Architect and shall be used
only on the job designated.
CHECKED
SCALE
DRAWN
DATE
AS NOTED
Syracuse, NY 13204Pittsford, NY 14534
Suite 201
WALL TYPES AND
SCHEDULES
A-001
10/24/2025
HHV DE
716-23-002
TO
W
N
O
F
I
T
H
A
C
A
2
N
D
F
L
O
O
R
&
C
O
U
R
T
O
F
F
I
C
E
R
E
N
O
V
A
T
I
O
N
TO
W
N
O
F
I
T
H
A
C
A
T
O
W
N
H
A
L
L
21
5
N
O
R
T
H
T
I
O
G
A
S
T
R
E
E
T
IT
H
A
C
A
,
N
Y
Cl
i
e
n
t
P
r
o
j
e
c
t
N
o
:
A
A
1
6
2
0
.
5
1
7
314
BID DOCUMENTS
SCALE:1" = 1'-0"1 WALL TYPES
SCALE:1/2" = 1'-0"3 ADA MOUNTING HEIGHTS
SCALE:N.T.S.2 ROOM FINISH SCHEDULE AND DOOR SCHEDULE
A/C AIR CONDITIONER
A.F.F ABOVE FINISHED FLOOR
A.F.G.ABOVE FINISHED GRADE
AG.ABOVE GRADE
ALT.ALTERNATE
ALUM.ALUMINUM
ANOD.ANODIZED
ASPH.ASPHALT
BLKG.BLOCKING
CCSF CLOSED-CELL SPRAY FOAM
CJ CONTROL JOINT
CONC.CONCRETE
CONST.CONSTRUCTION
CONT.CONTINUOUS
DIA.DIAMETER
DIM.DIMENSION
DIMS.DIMENSIONS
DWG.DRAWING
EA.EACH
EF EXHAUST FAN
EJ EXPANSION JOINT
ELEC.ELECTRICAL
EX. or EXIST.EXISTING
EXJT.EXPANSION JOINT
FIN.FINISH
FLR.FLOOR
GA.GAUGE
GALV.GALVANIZED
GYP.GYPSUM
HVAC HEATING, VENTILATION AND AIR
CONDITIONING
INC.INCLUDING
INSUL.INSULATED or INSULATION
LGMF LIGHT GAUGE METAL FRAMING
MANUF.MANUFACTURER
MAX.MAXIMUM
MECH.MECHANICAL
MEMB.MEMBRANE
MIN.MINIMUM
MTL.METAL
N.I.C.NOT-IN-CONTRACT
N.T.S.NOT TO SCALE
OZ. OUNCE
PLUMB.PLUMBING
PLYD.PLYWOOD
PNT.PAINT or PAINTED
PP PIPE PENETRATION
PRE POWER ROOF EXHAUST
P.S.F.POUNDS PER SQUARE FOOT
P.S.I.POUNDS PER SQUARE INCH
PT PRESSURE TREATED
PVC POLYVINYL CHLORIDE
REINF.REINFORCED
SF SQUARE FOOT
SIM. SIMILAR
S.S.STAINLESS-STEEL
STL.STEEL
STRUCT.STRUCTURE or STRUCTURAL
T&G TONGUE AND GROOVE
TYP.TYPICAL
V.I.F.VERIFY IN FIELD
V.R.VAPOR RETARDER
W/WITH
WD.WOOD
TYPICAL ABBREVIATIONS:
REGISTRATION EXPIRES: 08/31/2028
M02A
RESTROOM
M01
CORRIDOR
AD-201
1
4
3
2
AD-201
9
12
11
10
AD-201
5
8
7
6
M03
TENATE SPACE 2
M02
TENANT SPACE 1
3'-0"±
REMOVE/SALVAGE WINDOW SASH
FOR RESTORATION AND REINSTALLATIONREMOVE/SALVAGE WINDOW SASH
FOR RESTORATION AND REINSTALLATION
REMOVE DOOR, FRAME,
HARDWARE AND MARBLE
THRESHOLD. SALVAGE
FOR REINSTALLATION
REMOVE WOODEN
SHELVING IN ITS
ENTIRETY
REMOVE WINDOW TRIM, TYP.
REMOVE SECTION OF
PLASTER PARTITION AND
BACKUP FOR NEW DOOR
REMOVE WOOD PANEL
AND WINDOW TRIM
REMOVE WINDOW TRIM
REMOVE/SALVAGE WINDOW
SASH FOR RESTORATION AND
REINSTALLATION, TYP.
REMOVE WINDOW TRIM, TYP.
NOTE:
CONTRACTOR TO SECURE OPENINGS AND MAKE
WEATHER TIGHT WHILE WINDOWS ARE REMOVED., TYP.
EXISTING TERRAZZO
AND MARBLE FLOOR
TO REMAIN
EXISTING DUCT TO REMAIN EXISTING
DUCT TO
REMAIN.
SAND HANDRAIL,PREPARE FOR
NEW FINISH
REMOVE MARBLE WAINSCOT
IN ITS ENTIRETY. RETURN TO OWNER.
PREPARE SURFACE FOR NEW FINISHES
PIPE TO REMAIN
RADIATOR TO BE
REMOVED BY MECHANICAL
CONTRACTOR, TYP.
RADIATOR TO BE REMOVED
BY MECHANICAL
CONTRACTOR, TYP.
REMOVE
VENTS AND
PATCH
PLUMBING CONTRACTOR TO
REMOVE TOILET AND SINK.
GC TO PATCH AND FINISH, TYP.
6'-012"
6'
-
2
"
12
'
-
0
1
2"
5'
-
1
1
2"
REMOVALS
AD-101
3
TYP.
#PHOTO LOCATION
4
1
3
2, 2A
30'-3"
19
'
-
5
"
15'-11"
5
10"
REMOVE METAL STUD
PARTITIONS,DOOR, DOOR
FRAME AND HARDWARE
REMOVE TRANSACTION
WINDOW AND SHELF
REMOVE DOOR AND FRAME
REMOVE WALL TO THE
EXTENT SHOWN
REMOVE/SALVAGE WINDOW
SASH FOR RESTORATION AND
REINSTALLATION, TYP.
REMOVE ALL WINDOW TRIM,
TYP.
RADIATOR TO BE
REMOVED BY
MECHANICAL
CONTRACTOR, TYP.
REMOVE CARPET AND PAD.
REMOVE WALL TO
THE EXTENT SHOWN 106
RESTROOM
104
RESTROOM
103
RESTROOM
102
CORRIDOR
105
CORRIDOR
3
STAIR
101
LOBBY
111
TOWN BOARD/COURTROOM
108
CORRIDOR
109
OFFICE
110
OFFICE
107
OFFICE
NOTE:
REPLACE FLOOR TILE. PATCH AND REPAIR FLOOR AREAS
DAMAGED BY REMOVALS IN RESTROOMS 103 AND 104
PREPARE SURFACE FOR NEW FINISH. ± 60 S.F V.I.F. TOTAL
REMOVE LIGHT
REMOVE WINDOW AND TRIM
TOILETS AND GRAB BARS TO BE
REMOVED BY PLUMBING CONTRACTOR.
SAVE FOR REINSTALLATION.
REMOVE
AND
SALVAGE
DOOR AND
FRAME.
PROVIDE MIN. OF 3'-4" OPENING
FOR NEW ADA DOOR. DO NOT
DISTURB MARBLE
REMOVE MIRROR
AND GRAB BARSREMOVE AND SALVAGE
MIRROR AND SOAP
DISPENSER
REMOVE SINK, MIRROR,
SOAP DISPENSER AND
PAPER TOWEL. SAVE FOR
REINSTALLATION
REMOVE TOILET PARTITIONS IN
ITS ENTIRETY
RADIATOR TO BE REMOVED
BY MECHANICAL
CONTRACTOR
REMOVE VCT DOWN TO
SUBSTRATE
REMOVE WINDOW TRIM, TYP.
REMOVE/SALVAGE WINDOW SASH
FOR RESTORATION AND REINSTALLATION,
TYP.
REMOVE PLASTER
BACK TO EXISTING
MASONRY WALL
±8'-212"
NOTES:
1.ALL INTERIOR PARTITIONS THAT INTERSECT EXTERIORS
WALLS SHALL BE OPENED AND INSULATED AT THE
INTERSECTION TO A DEPTH EQUAL TO OR GREATER THAN
THE PROPOSED EXTERIOR WALL THICKNESS. PATCH
AND FINISH AREA.
2.CONTRACTOR TO SECURE OPENINGS AND PROVIDE
WEATHER TIGHTNESS REQUIREMENTS WHILE WINDOWS
ARE REMOVED. TYPICAL
3.UNLESS SPECIFICALLY INDICATED REMOVALS BY GC
4.PROVIDE ONE OPERATIONAL RESTROOM ACCESSIBLE
TO THE PUBLIC AT ALL TIMES.
PLUMBING CONTRACTOR TO
REMOVE TOILET, SINK
53'-412"
19
'
-
3
1
2"
10
'
-
8
1
2"
REMOVALS
REMOVE GRAB BARS
TOILETS TO BE REMOVED BY
PLUMBING CONTRACTOR.
SAVE FOR REINSTALLATION.
REMOVE TOILET PARTITIONS
IN ITS ENTIRETY
REMOVE HAT CHANNEL AND
GWB ON EXISTING
MASONRY WALL
RADIATOR TO BE REMOVED BY
MECHANICAL CONTRACTOR, TYP.
AD-101
4
TYP.
7
#PHOTO LOCATION
6
3'
-
4
"
PROVIDE R.O.
3'-4"X 7'-2"
FOR DOOR
SINK TO BE REMOVED
BY PLUMBING
CONTRACTOR. SAVE
FOR REINSTALLATION
EX. DOOR
TO REMAIN
REMOVE DOOR
91
2"
±1
'
-
2
"
REMOVE CHASE WALL
REMOVE WINDOW
SASH ONLY. WINDOW
FRAME TO REMAIN
REMOVE WINDOW TRIM.
TYPICAL
W6 W5 W6
REMOVE WINDOW
SASH ONLY.
WINDOW FRAME
TO REMAIN
REMOVE
WINDOW TRIM.
TYPICAL
EXISTING
TRIM PANELS
TO REMAIN
SHEET OF
SHEET NUMBER
SHEET TITLE
PROJECT NUMBER
PROJECT
NORTH
CONSULTANT
It is a violation of the New York State Education
Law, Article 145 Sec. 7209, for any person
unless he is acting under the direction of a
licensed professional Architect, Engineer or
Land Surveyor to alter an item in any way. If an
item bearing the seal of an Architect, Engineer
or Land Surveyor is altered, the altering
Architect, Engineer or Land Surveyor shall affix
to the item his seal and the notation "altered by"
followed by his signature and the date of such
alteration, and a specific description of the
alteration.
PROJECT
11
/
7
/
2
0
2
5
1
1
:
4
5
:
5
5
A
M
/HE
A
T
H
E
R
V
E
N
D
I
T
T
I
Fax (315) 487 - 5947
Syracuse, NY 13204
Tel (315) 488 - 0377
215 Wyoming Street
info@bellandspina.com
www.bellandspina.com
Fax (585) 487 - 9532
Pittsford, NY 14534
Tel (585) 200 - 5038
1160-C Pittsford-Victor Rd
DATEMARK DESCRIPTION
The Contractor shall verify all dimensions and
notify the Architect in writing of any
discrepancies.
All drawings and specifications are the
property of the Architect and shall be used
only on the job designated.
CHECKED
SCALE
DRAWN
DATE
AS NOTED
REMOVALS-FLOOR
PLANS
AD-101
10/24/2025
SLC -
716-23-002
TO
W
N
O
F
I
T
H
A
C
A
2
N
D
F
L
O
O
R
&
C
O
U
R
T
O
F
F
I
C
E
R
E
N
O
V
A
T
I
O
N
TO
W
N
O
F
I
T
H
A
C
A
T
O
W
N
H
A
L
L
21
5
N
O
R
T
H
T
I
O
G
A
S
T
R
E
E
T
IT
H
A
C
A
,
N
Y
Cl
i
e
n
t
P
r
o
j
e
c
t
N
o
:
A
A
1
6
2
0
.
5
1
7
315
BID DOCUMENTS
SCALE:1/4" = 1'-0"1 REMOVALS- 2ND FLOOR PLAN
SCALE:1/4" = 1'-0"2 REMOVALS-FIRST FLOOR PLAN
SCALE:1/32" = 1'-0"5 KEY PLAN
SCALE:1/2" = 1'-0"3 2ND FLOOR PARTIAL ELEVATION @ WINDOW
SCALE:1/2" = 1'-0"4 FIRST FLOOR PARTIAL ELEVATION @ WINDOW
PHOTO 7 TRANSACTION WINDOW
PHOTO 1 TRANSACTION WINDOW PHOTO 2 VENT REMOVAL
PHOTO 4 ROOM MO2
PHOTO 3
PHOTO 5 ROOM M02A
PHOTO 6 CLERK BATHROOM
REMOVAL
PHOTO 2A VENT REMOVAL
REGISTRATION EXPIRES: 08/31/2028
106
RESTROOM
102
CORRIDOR
108
CORRIDOR
110
OFFICE
CEILING HGT.
9'-0"
CEILING HGT.
9'-0"
CEILING HGT.
9'-0"
CEILING HGT.
9'-0"
CEILING HGT.
9'-0"
CEILING HGT.
8'-0"
104
RESTROOM
103
RESTROOM
111
TOWN BOARD/COURTROOM101
LOBBY
PROVIDE OPENING IN GWB
CEILING IN AREA SHOWN
FOR INSTALLATION OF
INSULATION
ACT CEILING
TO REMAIN
ACT CEILING
TO REMAIN
PROVIDE OPENING IN GWB
CEILING IN AREA SHOWN FOR
LGMF PARTITION AND
INSULATION, SEE 2/A-301 SIM.
109
OFFICE
REMOVE SOFFIT AND SALVAGE
CEILING GRID AND TILE TO THE
EXTENT SHOWN FOR LGMF
PARTITION AND INSULATION. SEE
1/A-301 AND 3/A-301. ASSUME 3'
DEEP
PROVIDE OPENING IN GWB
CEILING AS REQ'D IN AREA
SHOWN FOR LGMF PARTITION
AND INSULATION, SEE 2/A-301
SIM. ASSUME 3' DEEP.
SPRINKLERS, SMOKE/HEAT
AND DIFFUSERS TO REMAIN,
TYP.
SPRINKLERS, SMOKE/HEAT
AND DIFFUSERS TO REMAIN.
TYP.
SPRINKLERS, SMOKE/HEAT
AND DIFFUSERS TO REMAIN.
TYP.
SPRINKLERS TO
REMAIN
LIGHT TO BE REMOVED
BY ELECTRICAL
CONTRACTOR. GENERAL
CONTRACTOR TO PATCH
HOLES AND FINISH, TYP.
3
1
GENERAL NOTES:
1.LIGHTS TO BE REMOVED BY ELECTRICAL
CONTRACTOR. COORDINATE WITH E-SERIES,
TYP.
2.GENERAL CONTRACTOR TO PATCH HOLES,
ASSUME 50 S.F. PREP EXISTING GWB CEILINGS
FOR PAINTING, TYP.
EXISTING EXIT SIGN
TO REMAIN
EXISTING EXIT
SIGN TO REMAIN
M02A
RESTROOM
M03
TENANT SPACE 2
M02
TENANT SPACE 1 M01
CORRIDOR
LIGHTS TO BE REMOVED BY
ELECTRICAL CONTRACTOR.
GENERAL CONTRACTOR TO
PATCH HOLES AND FINISH, TYP.
EXISTING DUCT
EXISTING DUCT
EXISTING DUCT
EXISTING FIRE
SENSOR TO REMAIN
LIGHTS TO BE REMOVED BY
ELECTRICAL CONTRACTOR.
GENERAL CONTRACTOR TO
PATCH HOLES AND FINISH, TYP.
LIGHT TO BE REMOVED BY
ELECTRICAL CONTRACTOR.
GENERAL CONTRACTOR TO
PATCH HOLES AND FINISH, TYP.
2
GENERAL NOTES:
1.LIGHTS TO BE REMOVED BY ELECTRICAL
CONTRACTOR. COORDINATE WITH E-SERIES,
TYP.
2.GENERAL CONTRACTOR TO PATCH HOLES,
ASSUME 50 S.F. PREP EXISTING GWB CEILINGS
FOR PAINTING, TYP.
DIFFUSER SUPPLY
DIFFUSER RETURN
SPRINKLER
SMOKE/ HEAT
LEGEND
EMERGENCY
LIGHT
LIGHT
WALL MOUNTED
EXIT LIGHT
SHEET OF
SHEET NUMBER
SHEET TITLE
PROJECT NUMBER
PROJECT
NORTH
CONSULTANT
It is a violation of the New York State Education
Law, Article 145 Sec. 7209, for any person
unless he is acting under the direction of a
licensed professional Architect, Engineer or
Land Surveyor to alter an item in any way. If an
item bearing the seal of an Architect, Engineer
or Land Surveyor is altered, the altering
Architect, Engineer or Land Surveyor shall affix
to the item his seal and the notation "altered by"
followed by his signature and the date of such
alteration, and a specific description of the
alteration.
PROJECT
11
/
7
/
2
0
2
5
1
1
:
4
6
:
0
0
A
M
/HE
A
T
H
E
R
V
E
N
D
I
T
T
I
Fax (315) 487 - 5947
Tel (315) 488 - 0377
215 Wyoming Street
info@bellandspina.com
www.bellandspina.com
Fax (585) 487 - 9532
Suite 200
Tel (585) 200 - 5038
1163 Pittsford-Victor Rd
DATEMARK DESCRIPTION
The Contractor shall verify all dimensions and
notify the Architect in writing of any
discrepancies.
All drawings and specifications are the
property of the Architect and shall be used
only on the job designated.
CHECKED
SCALE
DRAWN
DATE
AS NOTED
Syracuse, NY 13204Pittsford, NY 14534
Suite 201
REMOVALS
REFLECTED CEILING
PLAN
AD-111
10/24/2025
HHV DE
716-23-002
TO
W
N
O
F
I
T
H
A
C
A
2
N
D
F
L
O
O
R
&
C
O
U
R
T
O
F
F
I
C
E
R
E
N
O
V
A
T
I
O
N
TO
W
N
O
F
I
T
H
A
C
A
T
O
W
N
H
A
L
L
21
5
N
O
R
T
H
T
I
O
G
A
S
T
R
E
E
T
IT
H
A
C
A
,
N
Y
Cl
i
e
n
t
P
r
o
j
e
c
t
N
o
:
A
A
1
6
2
0
.
5
1
7
316
BID DOCUMENTS
SCALE:1/32" = 1'-0"3 KEY PLAN
SCALE:1/4" = 1'-0"2 REMOVALS FIRST FLOOR REFLECTED CEILING PLAN
SCALE:1/4" = 1'-0"1 REMOVALS 2ND FLOOR REFLECTED CEILING PLAN
SCALE:N.T.S.-LEGEND
PHOTO 1 CEILING OFFICE 110
PHOTO 2 CEILING ROOM MO2
PHOTO 3 CEILING OFFICE 107
REGISTRATION EXPIRES: 08/31/2028
8'
-
1
1
"
12'-014"7'-43 4"
8"
REMOVE WINDOW TRIM
19'-5"
EXISTING METAL PIPE TO REMAIN
REMOVE/SALVAGE WINDOW
SASH FOR RESTORATION AND
REINSTALLATION, TYP.
RADIATOR TO BE
REMOVED BY MECHANICAL
CONTRACTOR
4"
EXISTING DUCTS TO REMAIN
CONDUIT AND JUNCTION BOX
TO BE REMOVED BY ELECTRICAL
CONTRACTOR
7'
-
6
"
1'
-
5
"
5'-112"1'-11"2'-33 8"3'-0"2'-612"2'-5"2'-11 2"
6'
-
8
"
REMOVE DOOR, AND ALL
RELATED HARDWARE.
SALVAGE FOR REUSE.
REFURBISH HARDWAREEXISTING DUCT TO
REMAIN REMOVE WOOD TRIM
SPRINKLER PIPE TO BE REMOVED BY
PLUMBING CONTRACTOR. GC TO
PATCH AND FINISH, TYP.
7'
-
6
"
1'
-
5
"
4"
9'-0"
8'
-
1
1
"
16'-23 8"4'-95 8"
REMOVE WINDOW
TRIM, TYP.
30'-0"
REMOVE/SALVAGE WINDOW
SASH FOR RESTORATION AND
REINSTALLATION, TYP.
RADIATOR TO BE
REMOVED BY MECHANICAL
CONTRACTOR
CONDUIT AND JUNCTION BOX
TO BE REMOVED BY ELECTRICAL
CONTRACTOR
3'
-
6
"
7'
-
6
"
6'-3"
REMOVE MARBLE
WAINSCOT, AND
DOOR TRIM, RETURN
MARBLE TO OWNER
CONDUIT AND
JUNCTION BOX
TO BE REMOVED
BY ELECTRICAL
CONTRACTOR
SPRINKLER PIPE TO BE
REMOVED BY PLUMBING
CONTRACTOR. GC TO PATCH
AND FINISH, TYP.
2'-812"
3'
-
6
"
7'
-
6
"
±
7
'
-
2
"
REMOVE SECTION OF
PLASTER PARTITION AND
BACKUP FOR NEW DOOR
REMOVE MARBLE
WAINSCOT, RETURN TO
OWNER
3'-0"6"
6'-21 2"
CONDUIT AND
JUNCTION BOX TO
BE REMOVED BY
ELECTRICAL
CONTRACTOR
6'-3"
3'
-
6
"
7'
-
6
"
REMOVE MARBLE
WAINSCOT, RETURN TO
OWNER
RADIATOR TO BE
REMOVED BY MECHANICAL
CONTRACTOR
SPRINKLER PIPES TO BE
REMOVED BY PLUMBING
CONTRACTOR. GC TO
PATCH AND FINISH, TYP.
6'-212"
3'
-
6
"
7'
-
6
"
REMOVE WOOD PANEL AND
TRIM, PREPARE OPENING
FOR REPLICA WINDOW
REMOVE MARBLE
WAINSCOT, RETURN TO
OWNER
±3
'
-
3
"
V
.
I
.
F
.
±2'-218"
V.I.F.
TOILET, SINK AND T.R.
ACCESSORIES TO BE
REMOVED BY PLUMBING
CONTRACTOR CAP BACK TO
SOURCE.
ALL CONDUIT, LIGHT AND FAN
TO BE REMOVED BY
ELECTRICAL CONTRACTOR.
GENERAL CONTRACTOR TO
PATCH AND REPAIR SURFACE
FOR NEW PAINT., TYP.
SPRINKLER PIPES TO BE
REMOVED BY PLUMBING
CONTRACTOR. GC TO
PATCH AND FINISH, TYP.
REMOVE PAPER TOWEL
DISPENSER, SOAP
DISPENSER AND TOWEL
BAR
7'-05 8"3'-0"5'-33 8"
15'-4"
8"
7'
-
6
"
6'
-
2
"
REMOVE WOODEN
SHELVING ITS
ENTIRETY
RADIATOR TO BE
REMOVED BY
MECHANICAL
CONTRACTOR
CONDUIT AND JUNCTION BOX
TO BE REMOVED BY ELECTRICAL
CONTRACTOR
15'-11"
EXISTING DUCTS
TO REMAIN
REMOVE VENT
INFILL, PATCH AND
PAINT
PIPE TO REMAIN
REMOVE WOODEN
SHELVING IN ITS
ENTIRETY
PIPES TO BE REMOVED
BY MECHANICAL CONTRACTOR 3'-4"12'-0"
7'
-
6
"
15'-4"
REMOVE WOODEN
SHELVING IN ITS
ENTIRETY
PLUMBING CONTRACTOR TO ADJUST
PIPE ± 6" TO ACCOMMODATE NEW
WALL THICKNESS.
EXISTING DUCTS
TO REMAIN
PIPES TO REMAIN
15'-1012"
7'
-
6
"
8"
REMOVE WOODEN
SHELVING IN ITS
ENTIRETY
REMOVE WINDOW TRIM
REMOVE/SALVAGE WINDOW
SASH FOR RESTORATION AND
REINSTALLATION, TYP.
SPRINKLER PIPES TO BE
REMOVED BY PLUMBING
CONTRACTOR
JUNCTION BOX
TO BE REMOVED
BY ELECTRICAL
CONTRACTOR
PIPE TO RADIATOR TO
BE REMOVED BY
MECHANICAL
CONTRACTOR
SHEET OF
SHEET NUMBER
SHEET TITLE
PROJECT NUMBER
PROJECT
NORTH
CONSULTANT
It is a violation of the New York State Education
Law, Article 145 Sec. 7209, for any person
unless he is acting under the direction of a
licensed professional Architect, Engineer or
Land Surveyor to alter an item in any way. If an
item bearing the seal of an Architect, Engineer
or Land Surveyor is altered, the altering
Architect, Engineer or Land Surveyor shall affix
to the item his seal and the notation "altered by"
followed by his signature and the date of such
alteration, and a specific description of the
alteration.
PROJECT
11
/
7
/
2
0
2
5
1
1
:
4
6
:
0
9
A
M
/HE
A
T
H
E
R
V
E
N
D
I
T
T
I
Fax (315) 487 - 5947
Syracuse, NY 13204
Tel (315) 488 - 0377
215 Wyoming Street
info@bellandspina.com
www.bellandspina.com
Fax (585) 487 - 9532
Pittsford, NY 14534
Tel (585) 200 - 5038
1160-C Pittsford-Victor Rd
DATEMARK DESCRIPTION
The Contractor shall verify all dimensions and
notify the Architect in writing of any
discrepancies.
All drawings and specifications are the
property of the Architect and shall be used
only on the job designated.
CHECKED
SCALE
DRAWN
DATE
AS NOTED
REMOVALS-INTERIOR
ELEVATIONS
AD-201
10/24/2025
SLC DE
716-23-002
TO
W
N
O
F
I
T
H
A
C
A
2
N
D
F
L
O
O
R
&
C
O
U
R
T
O
F
F
I
C
E
R
E
N
O
V
A
T
I
O
N
TO
W
N
O
F
I
T
H
A
C
A
T
O
W
N
H
A
L
L
21
5
N
O
R
T
H
T
I
O
G
A
S
T
R
E
E
T
IT
H
A
C
A
,
N
Y
Cl
i
e
n
t
P
r
o
j
e
c
t
N
o
:
A
A
1
6
2
0
.
5
1
7
317
BID DOCUMENTS
SCALE:3/8" = 1'-0"1 REMOVALS - TENANT SPACE 1 M02- WEST ELEVATION
SCALE:3/8" = 1'-0"2 REMOVALS - TENANT SPACE 1 MO2- NORTH ELEVATION
SCALE:3/8" = 1'-0"3 REMOVALS - TENANT SPACE 1 MO2 - EAST ELEVATION
SCALE:3/8" = 1'-0"4 REMOVALS - TENANT SPACE 1 MO2 - SOUTH ELEVATION
SCALE:3/8" = 1'-0"5 MO2A-WEST EL.
SCALE:3/8" = 1'-0"6 REMOVALS-M02A-NORTH EL.
SCALE:3/8" = 1'-0"7 REMOVALS-M02A - EAST EL.
SCALE:3/8" = 1'-0"8 REMOVALS - M02A - SOUTH EL.
SCALE:3/8" = 1'-0"9 REMOVALS - TENANTE SPACE 2 MO3 - WEST ELEVATION
SCALE:3/8" = 1'-0"10 REMOVALS - TENANT SPACE 2 MO3- NORTH ELEVATION
SCALE:3/8" = 1'-0"11 REMOVALS - TENANT SPACE 2 MO3- EAST ELEVATION
SCALE:3/8" = 1'-0"12 REMOVALS - TENANT SPACE 2 MO3 - SOUTH ELEVATION
GENERAL NOTES:
1.PATCH ALL HOLES, ASSUME 10 SF
REGISTRATION EXPIRES: 08/31/2028
105
CORRIDOR
3
STAIR
101
LOBBY
111
TOWN BOARD/COURTROOM
108
CORRIDOR
109
OFFICE
110
OFFICE
105-1
03
02
03 03 03 03 03
3'-0"
107
OFFICE
W11
104
RESTROOM
103
RESTROOM
102
CORRIDOR
2'-7"
2'-6" MIN.5'-0"
01
BULLET-RESISTANT
VERTICAL BAFFLE
TRANSACTION WINDOW
CARPET TILE
CARPET TILE
PAINT
PROVIDE SMOOTH TRANSITION
FROM EXISTING WALL,
PAINT
PAINT
CARPET TILE
PAINT
PAINT
2'-6"
3'-2"
1'-3"
5'
-
0
"
5'-0"
06
104-1
10
7
-
1
±1'-6"
REINSTALL WINDOWS, TYP.
TRIM, PAINT, TYP.
PLUMBING CONTRACTOR TO
REINSTALL TOILET. SEE NOTE 1.
PLUMBING
CONTRACTOR TO
INSTALL URINAL. SEE
3/A001. FOR MOUNTING
HGTS.
REINSTALL GRAB BARS PROVIDE
ADDITIONAL BLOCKING AS
REQUIRED. SEE 3/A001 FOR
MOUNTING HGTS.
TOILET PARTITIONS
TOILET PARTITIONS
PLUMBING CONTRACTOR TO
REINSTALL TOILETS. SEE NOTE 1.
REPLACE TILE IN AREAS DAMAGED
BY REMOVALS IN TOILET ROOMS
103 AND 104. MATCH EXISTING. ± 10
S.F V.I.F.
W8
NOTE: CONTRACTOR TO FOAM ALL
WEIGHT POCKETS IN WINDOWS FOR
AIR TIGHTNESS, TYP.
07
PATCH AND PAINT AREA
DISTURBED BY WALL
REMOVAL, MATCH EXISTING
REINSTALL TOILET ROOM
ACCESSORIES. SEE 3/A001 FOR
MOUNTING HGTS., TYP.
REINSTALL GRAB BARS AND TOILET
ROOM ACCESSORIES PROVIDE
ADDITIONAL BLOCKING. SEE 3/A001
FOR MOUNTING HGTS.
W7 W8W7W8W7
W8W7
A-301
1
A-301
4
A-301
3
A-301
2
A-301
4
A-301
5
A-301
2
A-301
3
SIM.
A-301
2
SIM.SIM.
3-1
DO NOT DISTURB
MARBLE IN LOBBY
CARPET TILE
8'-73 4"
PROVIDE WOOD 1 1
4"DIA.
HANDRAIL
1'
-
1
3
4"
2'
-
0
"
CABINET
NOTE:
1.PLUMBING FIXTURES TO BE INSTALLED BY
PLUMBING CONTRACTOR. COORDINATE WITH
P-SERIES.
2.GC TO INSTALL ALL NECESSARY BLOCKING.
3.GC TO PERFORM ALL CORING AND DRILLING.
COORDINATE LOCATION WITH PLUMBING
CONTRACTOR.
4.GC TO PATCH ALL HOLES CREATED BY OTHER
TRADES. PREP AND PAINT, TYP.
WALL MOUNTED THERMOSTAT
AND FIRE ALARM TO REMAIN.
ELECTRICAL CONTRACTOR TO
MOVE IF THERE IS A CONFLICT
PROVIDE 4' WAINSCOT FRP,
APPLIED TO ALL WALLS IN
ROOM 103 AND ROOM 104,
TYP.
PROVIDE 4' WAINSCOT FRP,
APPLIED TO ALL WALLS IN
ROOM 103 AND ROOM 104,
TYP.
1'-6"
2'
-
4
"
1'-6"
±53 4"
2/A-301
3/A-301
6/A-301
7/A-301 PACK ABUTMENT OF
EXISTING PARTITIONS
WITH INSULATION FOR
CONTINUITY
7'
-
1
0
1
4"
3'
-
4
"
A-501
10
PROVIDE
BLOCKING
FOR ELECTRIC
HEATER. SEE
M-SERIES
PROVIDE
BLOCKING
FOR ELECTRIC
HEATER. SEE
M-SERIES 10
3
-
1
06
1'
-
6
"
M
I
N
.
M03
TENATE SPACE 2
M02
TENANT SPACE 1
M01
CORRIDOR
03
03
04
04
04
05
03 03 03 03
PATCH AND PAINT ALL WALLS
IN STAIRWELL AND CORRIDOR.,
TYP.
INFILL FORMER
DOOR RO WITH
FRAMING AND PATCH
PLASTER TO MATCH
EXISTING
PATCH AND PAINT
WALLS, TYP.
CARPET TILE
CARPET TILE
CLEAN AND POLISH
EXISTING TERRAZZO
AND MARBLE FLOOR
PLUMBING CONTRACTOR TO INSTALL
NEW TOILET AND SALVAGED SINK
FROM RM 106.
PATCH AND PAINT
WALLS AND TRIM
200 SQ.FT.
REINSTALL DOOR,
PAINT
TRIM, MATCH
EXISTING. PAINT
MO2A-1
PATCH AND PAINT
EXISTING WALLS, TYP.
GWB, PAINT, TYP.
GWB, PAINT,
TYP.
GWB, PAINT,
TYP.
A-201
5
8
7
6
A-201
1
4
3
2
A-201
9
12
11
10
M02A
RESTROOMW5
REINSTALL WINDOWS, TYP.
CONTRACTOR TO FOAM ALL
WEIGHT POCKETS IN WINDOWS FOR
AIR TIGHTNESS, TYP.
REINSTALL WINDOWS, TYP.
NOTE: CONTRACTOR TO FOAM ALL
WEIGHT POCKETS IN WINDOWS FOR
AIR TIGHTNESS, TYP.
CARPET TILE
WOOD BASE ON ALL
NEW WALLS. PAINT,
TYP.
PAINT WOOD BASE., TYP.
PAINT WOOD
BASE., TYP.
PAINT WOOD
BASE., TYP.
REFINISH RAILING
MO2-2
9'-8"
2'
-
1
0
12"
2'-5"2'-012"
1'
-
1
1
"
2'-61 2"
2'
-
0
12"
±2
'
-
8
"
04
PATCH ABANDONED VENTS
W6 W11W5W6 W5 W6
W5 W6
MO2-1 MO3-1
PROVIDE 1 1/4" DIA.
WOODEN HANDRAIL
3'-10 12"2'-4"
NOTE:
1.PLUMBING FIXTURES TO BE INSTALLED BY
PLUMBING CONTRACTOR. COORDINATE WITH
P-SERIES.
2.GC TO INSTALL ALL NECESSARY BLOCKING.
3.GC TO PERFORM ALL CORING AND DRILLING.
COORDINATE LOCATION WITH MECHANICAL,
PLUMBING AND ELECTRICAL CONTRACTOR.
4.GC TO PATCH ALL HOLES CREATED BY OTHER
TRADES. PREP FOR PAINTING, TYP.
5.GC TO COORDINATE WITH MECHANICAL ,
ELECTRICAL, AND PLUMBING CONTRACTOR
FOR MOUNTING LOCATIONS.
CLEAN STAIR
TREADS &
RISERS, TYP.
PAINT DOOR
AND FRAME
MO1-1
SHEET OF
SHEET NUMBER
SHEET TITLE
PROJECT NUMBER
PROJECT
NORTH
CONSULTANT
It is a violation of the New York State Education
Law, Article 145 Sec. 7209, for any person
unless he is acting under the direction of a
licensed professional Architect, Engineer or
Land Surveyor to alter an item in any way. If an
item bearing the seal of an Architect, Engineer
or Land Surveyor is altered, the altering
Architect, Engineer or Land Surveyor shall affix
to the item his seal and the notation "altered by"
followed by his signature and the date of such
alteration, and a specific description of the
alteration.
PROJECT
11
/
7
/
2
0
2
5
1
1
:
4
6
:
1
9
A
M
/HE
A
T
H
E
R
V
E
N
D
I
T
T
I
Fax (315) 487 - 5947
Syracuse, NY 13204
Tel (315) 488 - 0377
215 Wyoming Street
info@bellandspina.com
www.bellandspina.com
Fax (585) 487 - 9532
Pittsford, NY 14534
Tel (585) 200 - 5038
1160-C Pittsford-Victor Rd
DATEMARK DESCRIPTION
The Contractor shall verify all dimensions and
notify the Architect in writing of any
discrepancies.
All drawings and specifications are the
property of the Architect and shall be used
only on the job designated.
CHECKED
SCALE
DRAWN
DATE
AS NOTED
FLOOR PLANS
A-101
10/24/2025
SLC -
716-23-002
TO
W
N
O
F
I
T
H
A
C
A
2
N
D
F
L
O
O
R
&
C
O
U
R
T
O
F
F
I
C
E
R
E
N
O
V
A
T
I
O
N
TO
W
N
O
F
I
T
H
A
C
A
T
O
W
N
H
A
L
L
21
5
N
O
R
T
H
T
I
O
G
A
S
T
R
E
E
T
IT
H
A
C
A
,
N
Y
Cl
i
e
n
t
P
r
o
j
e
c
t
N
o
:
A
A
1
6
2
0
.
5
1
7
318
BID DOCUMENTS
SCALE:1/4" = 1'-0"8 FIRST FLOOR PLAN
SCALE:1/4" = 1'-0"3 2ND FLOOR PLAN
SCALE:1/32" = 1'-0"6 KEY PLAN
REGISTRATION EXPIRES: 08/31/2028
-
ATTIC SPACE
± 54'-8"
±8
9
'
-
0
"
A-102
1
HIP ROOF ABOVE
EXISTING STAIR TO
MEZZANINE DN
EXISTING CAT WALK
EXISTING LOUVER TO REMAIN.
N.I.C.
EXISTING LOUVER TO REMAIN.
N.I.C.
SEE NOTE 4B A-600
REMOVE/SALVAGE DORMER
WINDOW FOR RESTORATION
AND REINSTALLATION
REMOVE/SALVAGE DORMER
WINDOW FOR RESTORATION
AND REINSTALLATION
6" MINERAL WOOL
INSULATION WITH SMART
VAPOR RETARDER., TYP.
AREA OF VAULTED
CEILING BELOW
REMOVE EXISTING
LOOSE INSULATION
AS REQUIRED
1
2
34
5
6
SEE NOTE 4A A-600
-
ATTIC SPACE
6" MINERAL WOOL
INSULATION BETWEEN
EXISTING RAFTERS WITH
SMART VAPOR RETARDER,
TYP.
6" METAL STUD FRAMING
WITH 6" MINERAL WOOL
INSULATION WITH SMART
VAPOR RETARDER DOWN
TO VAULTED CEILING
BELOW
VAULTED CEILING
PLUMBING CONTRACTOR TO RELOCATE AND PROTECT
ALL SPRINKLER HEADS AS REQ'D AND RETAIN ALL
BRANCH PIPING FOR INSTALLATION OF INSULATION.
A-701
12
TYPICAL
RETURN 6" MINERAL WOOL
INSULATION WITH SMART
VAPOR RETARDER, TYP.
A-102
3
A-102
4
EXISTING PLASTER
VAULTED CEILING
MINERAL WOOL INSULATION
EXISTING MASONRY
WALL
6" METAL STUD FRAMING.
SPACING TO COINCIDE WITH
EXISTING RAFTER SPACING.
V.I.F.
SMART VAPOR RETARDER.
SEAL TO WALL WITH MASTIC
FILL VOID WITH INSULATION
R-25
EXISTING MASONRY
WALL
MINERAL WOOL
INSULATION.
SMART VAPOR
RETARDER
6" METAL STUD FRAMING.
SPACING TO COINCIDE WITH
EXISTING RAFTER SPACING.
V.I.F.
R-25
SHEET OF
SHEET NUMBER
SHEET TITLE
PROJECT NUMBER
PROJECT
NORTH
CONSULTANT
It is a violation of the New York State Education
Law, Article 145 Sec. 7209, for any person
unless he is acting under the direction of a
licensed professional Architect, Engineer or
Land Surveyor to alter an item in any way. If an
item bearing the seal of an Architect, Engineer
or Land Surveyor is altered, the altering
Architect, Engineer or Land Surveyor shall affix
to the item his seal and the notation "altered by"
followed by his signature and the date of such
alteration, and a specific description of the
alteration.
PROJECT
11
/
7
/
2
0
2
5
1
1
:
4
6
:
2
9
A
M
/HE
A
T
H
E
R
V
E
N
D
I
T
T
I
Fax (315) 487 - 5947
Tel (315) 488 - 0377
215 Wyoming Street
info@bellandspina.com
www.bellandspina.com
Fax (585) 487 - 9532
Suite 200
Tel (585) 200 - 5038
1163 Pittsford-Victor Rd
DATEMARK DESCRIPTION
The Contractor shall verify all dimensions and
notify the Architect in writing of any
discrepancies.
All drawings and specifications are the
property of the Architect and shall be used
only on the job designated.
CHECKED
SCALE
DRAWN
DATE
AS NOTED
Syracuse, NY 13204Pittsford, NY 14534
Suite 201
ATTIC FLOOR PLAN
AND SECTION
A-102
10/24/2025
HHV DE
716-23-002
TO
W
N
O
F
I
T
H
A
C
A
2
N
D
F
L
O
O
R
&
C
O
U
R
T
O
F
F
I
C
E
R
E
N
O
V
A
T
I
O
N
TO
W
N
O
F
I
T
H
A
C
A
T
O
W
N
H
A
L
L
21
5
N
O
R
T
H
T
I
O
G
A
S
T
R
E
E
T
IT
H
A
C
A
,
N
Y
Cl
i
e
n
t
P
r
o
j
e
c
t
N
o
:
A
A
1
6
2
0
.
5
1
7
319
BID DOCUMENTS
SCALE:1/8" = 1'-0"2 ATTIC PLAN
SCALE:1/8" = 1'-0"1 ATTIC SECTION
SCALE:1/32" = 1'-0"5 KEY PLAN
SCALE:1/2" = 1'-0"3 SECTION ELEVATION
SCALE:1/2" = 1'-0"4 PLAN DETAIL
NOTE:
1. WEIGHT CANNOT BE APPLIED TO PLASTER CEILING.
CONTRACTOR MUST PROVIDE WORK SURFACE OVER
STRUCTURE TO SUPPORT INSTALLERS.
PHOTO 1 CAT WALK ATTIC
PHOTO 2 ATTIC WINDOW (TYPICAL)
PHOTO 3 ATTIC DUCT
PHOTO 4 VAULTED CEILING FROM
ATTIC
PHOTO 5 DUCT WORK IN ATTIC
FROM CATWALK
PHOTO 6 DUCT WORK AND
FIREPROTECTION IN ATTIC
REGISTRATION EXPIRES: 08/31/2028
105
CORRIDOR
3
STAIR
101
LOBBY
111
TOWN BOARD/COURTROOM
108
CORRIDOR
109
OFFICE
110
OFFICE107
OFFICE
104
RESTROOM
103
RESTROOM
102
CORRIDOR
PAINT
PATCH AND PAINT GWB
IN THESE AREAS OF
WALL AND CEILING
REMOVAL
PAINT
PAINT
PAINT
PAINT
REPAIR OR REPLACE
CEILING GRID, TILE AND
SOFFIT IN AREAS AFFECTED
BY NEW WORK
A-301
3
PAINT
A-301
4
A-301
4
SIM
PAINT
A-301
2
PATCH AND PAINT GWB
IN THESE AREAS OF
WALL AND CEILING
REMOVAL. V.I.F.
PROVIDE ADDITIONAL
CEILING GRID SECTIONS
AT FORMER LIGHT
LOCATION
A-301
1
A-301
2
SIM
A-301
3
A-301
2
SIM
A-301
5
4'-0"
7'
-
2
"
3'-2"6'-11"3'-412"
4'
-
3
"
EQ.9'-1"EQ.
2'
-
1
0
"
8'-6"
EQ
.
EQ
.
EQ.
EQ
.
EQ
.
7'
-
0
"
EQ.
EQ.
EQ
.
EQ
.
EQ.
6'
-
7
12"
3'
-
7
12"
EQ
.
EQ
.
EQ.EQ.
M03
TENANT SPACE 2
M02
TENANT SPACE 1
PAINT
PAINT
PAINT
PAINT, TYP.
REPAIR HOLES IN CEILING
PROVIDE SMOOTH FINISH TO
RECEIVE PAINT
M02A
RESTROOM
M01
CORRIDOR
6'-3"
4'
-
8
"
8'
-
3
"
8'-8"8'-8"
EQ.
EQ
.
1'-4"
7'
-
6
"
EQ
.
EQ
.
EQ.EQ.7'-10"EQ.EQ
.
DIFFUSER SUPPLY
DIFFUSER RETURN
SPRINKLER
SMOKE/ HEAT
LEGEND
EMERGENCY
LIGHT
LIGHT
WALL MOUNTED
EXIT LIGHT
SHEET OF
SHEET NUMBER
SHEET TITLE
PROJECT NUMBER
PROJECT
NORTH
CONSULTANT
It is a violation of the New York State Education
Law, Article 145 Sec. 7209, for any person
unless he is acting under the direction of a
licensed professional Architect, Engineer or
Land Surveyor to alter an item in any way. If an
item bearing the seal of an Architect, Engineer
or Land Surveyor is altered, the altering
Architect, Engineer or Land Surveyor shall affix
to the item his seal and the notation "altered by"
followed by his signature and the date of such
alteration, and a specific description of the
alteration.
PROJECT
11
/
7
/
2
0
2
5
1
1
:
4
6
:
3
4
A
M
/HE
A
T
H
E
R
V
E
N
D
I
T
T
I
Fax (315) 487 - 5947
Tel (315) 488 - 0377
215 Wyoming Street
info@bellandspina.com
www.bellandspina.com
Fax (585) 487 - 9532
Suite 200
Tel (585) 200 - 5038
1163 Pittsford-Victor Rd
DATEMARK DESCRIPTION
The Contractor shall verify all dimensions and
notify the Architect in writing of any
discrepancies.
All drawings and specifications are the
property of the Architect and shall be used
only on the job designated.
CHECKED
SCALE
DRAWN
DATE
AS NOTED
Syracuse, NY 13204Pittsford, NY 14534
Suite 201
REFLECTED CEILING
PLANS
A-111
10/24/2025
HHV DE
716-23-002
TO
W
N
O
F
I
T
H
A
C
A
2
N
D
F
L
O
O
R
&
C
O
U
R
T
O
F
F
I
C
E
R
E
N
O
V
A
T
I
O
N
TO
W
N
O
F
I
T
H
A
C
A
T
O
W
N
H
A
L
L
21
5
N
O
R
T
H
T
I
O
G
A
S
T
R
E
E
T
IT
H
A
C
A
,
N
Y
Cl
i
e
n
t
P
r
o
j
e
c
t
N
o
:
A
A
1
6
2
0
.
5
1
7
3110
BID DOCUMENTS
SCALE:1/4" = 1'-0"2 FIRST FLOOR REFLECTED CEILING PLAN
SCALE:1/4" = 1'-0"1 2ND FLOOR REFLECTED CEILING PLAN
SCALE:1/32" = 1'-0"8 KEY PLAN
SCALE:N.T.S.9 LEGEND
1.PATCH HOLES FROM LIGHTING FIXTURE REMOVALS AND PREP FOR PAINTING.
2.LIGHTING FIXTURES, EXIT SIGNS, AND SMOKE/HEAT DETECTORS TO BE INSTALLED BY
ELECTRICAL CONTRACTOR. COORDINATE WITH E-SERIES, TYP.
3.INFORM ARCHITECT IF LIGHTING FIXTURE LOCATIONS CONFLICT WITH EXISTING
SPRINKLERS, DIFFUSERS OR HEAT/SMOKE DETECTORS.
GENERAL RCP NOTES:
REGISTRATION EXPIRES: 08/31/2028
8'
-
1
1
"
19'-03 4"
11'-8"7'-43 4"
8"
AD-201PAINT
WOOD TRIM, MATCH
EXISTING PROFILE, PAINT,
TYP.
REINSTALL WINDOW SASH,
PAINT
EX. METAL PIPE,
PAINT
19'-03 4"
EXISTING WOOD
BASE, PAINT,
TYP.
4"
2'-5"9'-314"17'-103 4"
AD-20129'-3"
PAINT
GWB, PAINT
WOOD BASE MATCH
EXISTING, PAINT
± 29'-7"
DATA CLOSET DOOR
WOOD TRIM, MATCH
EXISTING. PAINT
EXISTING WOOD
BASE. PAINT,
TYP.
±4'-95 8"
7'
-
6
"
1'
-
5
"
4"
±8'-75 8"
8'
-
1
1
"
±16'-23 8"
PAINT, TYP.
EX. PIPE,
PAINT
WOOD TRIM,
MATCH EXISTING
PROFILE, PAINT
REINSTALL
WINDOW SASH,
PAINT
WOOD TRIM,
MATCH EXISTING
PROFILE, PAINT
REINSTALL
WINDOW SASH,
PAINT
± 29'-7 3 4"
EXISTING WOOD
BASE PAINT,
TYP.
FAN COIL, INSTALLED
BY MECHANICAL
CONTRACTOR
7'
-
6
"
1'
-
5
"
± 5'-112"1'-11"3'-93 8"3'-712"1'-414"
±7
'
-
2
"
PAINT, TYP.
GWB CHASE, PAINT
EXISTING BULKHEAD,
PAINT
±3'-3"
INFILL WALL THIS AREA FROM
DOOR REMOVAL. PATCH AND
MATCH EXISTING WALL FINISH,
PAINT
EXISTING WOOD TRIM AND
DOOR, PAINT
19'-012"
WOOD BASE
MATCH EXISTING,
PAINT
WOOD BASE,
MATCH EXISTING,
PAINT
SPRINKLER PIPE TO
BE INSTALLED BY
PLUMBING
CONTRACTOR
EXISTING WOOD
BASE PAINT.
TYP.
7'
-
6
"
6'-3"
PAINT
3'
-
6
"
TILE
SOAP DISPENSER
AND PAPER TOWEL
DISPENSER
INFILLED AREA
FROM DOOR
REMOVAL
SPRINKLER PIPE TO
BE INSTALLED BY
PLUMBING CONTRACTOR
7'
-
6
"
PAINT
TRIM, MATCH
EXISTING, PAINT
REINSTALL SALVAGED
DOOR AND HARDWARE,
PAINT
TILE
3'
-
6
"
WALL MOUNTED
HEATER INSTALLED BY
MECHANICAL CONTRACTOR.
CENTER ON WALL
SPRINKLER PIPE TO
BE INSTALLED BY
PLUMBING CONTRACTOR
5'-103 4"
7'
-
6
"
PAINT
PATCH ALL AREAS
DAMAGED BY MEP
REMOVAL, TYP.
TILE
3'
-
6
"
SPRINKLER PIPE TO
BE INSTALLED BY
PLUMBING CONTRACTOR
6'-212"
±2'-93 4"±3'-43 4"
7'
-
6
"
WINDOW
TRIM, MATCH
EXISTING PROFILE,
PAINT
TILE T1
3'
-
6
"
MIRROR
PATCH WALL IN
DAMAGED AREA,
PAINT, TYP.
SPRINKLER PIPE TO
BE INSTALLED BY
PLUMBING CONTRACTOR
15'-018"
8"
7'
-
6
"
PAINT EXISTING WOOD
DOOR AND TRIM,
PAINT, TYP.
EXISTING WOOD BASE
PAINT, TYP.
15'-63 4"
PAINT, TYP.
EXISTING WOOD BASE,
PAINT, TYP.
WOOD BASE MATCH
EXISTING. PAINT
GWB,
PAINT
PAINT
INFILL AREA
FROM VENT
REMOVAL
7'
-
6
"
14'-113 4"
PAINT PIPES, TYP.
PAINT GWB,
PAINT
WOOD BASE, MATCH
EXISTING, PAINT
PAINT, TYP.
4'-21 4"11'-49 16"
15'-63 4"
7'
-
6
"
PAINT
WOOD TRIM, MATCH
EXISTING PROFILE, PAINT
REINSTALL WINDOW SASH,
PAINT
FAN COIL, INSTALLED
BY MECHANICAL
CONTRACTOR
SPRINKLER PIPE TO
BE INSTALLED BY
PLUMBING CONTRACTOR
EXISTING
PIPE, PAINT
EXISTING WOOD
BASE, PAINT
SHEET OF
SHEET NUMBER
SHEET TITLE
PROJECT NUMBER
PROJECT
NORTH
CONSULTANT
It is a violation of the New York State Education
Law, Article 145 Sec. 7209, for any person
unless he is acting under the direction of a
licensed professional Architect, Engineer or
Land Surveyor to alter an item in any way. If an
item bearing the seal of an Architect, Engineer
or Land Surveyor is altered, the altering
Architect, Engineer or Land Surveyor shall affix
to the item his seal and the notation "altered by"
followed by his signature and the date of such
alteration, and a specific description of the
alteration.
PROJECT
11
/
7
/
2
0
2
5
1
1
:
4
6
:
4
4
A
M
/HE
A
T
H
E
R
V
E
N
D
I
T
T
I
Fax (315) 487 - 5947
Syracuse, NY 13204
Tel (315) 488 - 0377
215 Wyoming Street
info@bellandspina.com
www.bellandspina.com
Fax (585) 487 - 9532
Pittsford, NY 14534
Tel (585) 200 - 5038
1160-C Pittsford-Victor Rd
DATEMARK DESCRIPTION
The Contractor shall verify all dimensions and
notify the Architect in writing of any
discrepancies.
All drawings and specifications are the
property of the Architect and shall be used
only on the job designated.
CHECKED
SCALE
DRAWN
DATE
AS NOTED
INTERIOR
ELEVATIONS
A-201
10/24/2025
SLC DE
716-23-002
TO
W
N
O
F
I
T
H
A
C
A
2
N
D
F
L
O
O
R
&
C
O
U
R
T
O
F
F
I
C
E
R
E
N
O
V
A
T
I
O
N
TO
W
N
O
F
I
T
H
A
C
A
T
O
W
N
H
A
L
L
21
5
N
O
R
T
H
T
I
O
G
A
S
T
R
E
E
T
IT
H
A
C
A
,
N
Y
Cl
i
e
n
t
P
r
o
j
e
c
t
N
o
:
A
A
1
6
2
0
.
5
1
7
3111
BID DOCUMENTS
SCALE:3/8" = 1'-0"1 TENANT SPACE 1 MO2 - WEST ELEVATION
SCALE:3/8" = 1'-0"2 TENANT SPACE 1 MO2- NORTH ELEVATION
SCALE:3/8" = 1'-0"4 TENANT SPACE 1 MO2- SOUTH ELEVATION
SCALE:3/8" = 1'-0"3 TENANT SPACE 1 MO2- EAST ELEVATION
SCALE:3/8" = 1'-0"5 MO2A-WEST EL.
SCALE:3/8" = 1'-0"6 MO2A-NORTH EL.
SCALE:3/8" = 1'-0"7 MO2A-EAST EL.
SCALE:3/8" = 1'-0"8 MO2A-SOUTH EL.
SCALE:3/8" = 1'-0"9 TENANT SPACE 2 MO3- WEST ELEVATION
SCALE:3/8" = 1'-0"10 TENANT SPACE 2 MO3- NORTH ELEVATION
SCALE:3/8" = 1'-0"11 TENANT SPACE 2 MO3- EAST ELEVATION
SCALE:3/8" = 1'-0"12 TENANT SPACE 2 MO3- SOUTH ELEVATION
1.PATCH ALL AREAS DAMAGED BY
MEP REMOVALS, TYP. ASSUME
50 SF
2.PREP & PAINT EXPOSED CONDUIT
TO MATCH WALL, TYP.
GENERAL NOTES:
REGISTRATION EXPIRES: 08/31/2028
EXISTING MASONRY
WALL
5 8" GWB, PAINT
FINISH FLOOR
BASE, SEE FINISH SCHEDULE
EXISTING ACT
CEILING
ACT CEILING TIE INTO
EXISTING ACT
3 5 8" MINERAL WOOL INSULATION
VAPOR RETARDER,
SEAL TO FLOOR AND CEILING
3 5 8" LIGHT GAUGE METAL
FRAMING
±9
'
-
0
"
FIRST
FLOOR
STRUCTURE ABOVE
±1
2
'
-
0
"
1,4,5 TYPICAL
3'-0" V.I.F
03
CARRY 5 8" GWB
ABOVE CEILING
EXISTING MASONRY
WALL
5 8" GWB, PAINT
FINISH FLOOR
BASE, SEE FINISH SCHEDULE
3 5 8" MINERAL WOOL INSULATION
VAPOR RETARDER,
SEAL TO FLOOR AND CEILING
3 5 8" LIGHT GAUGE METAL
FRAMING
±9
'
-
0
"
FIRST
FLOOR
STRUCTURE ABOVE
±1
2
'
-
0
"
EXISTING
CEILING, PAINT
AS REQUIRED,
ASSUME 3'
3'-0" V.I.F
03
LIGHT GAUGE METAL
FRAMING AND 5/8" GWB,
ALIGN WITH EXISTING CEILING
PROVIDE SMOOTH
TRANSITION. PAINT
5 8" GWB, PAINT
FINISH FLOOR
3 5 8" MINERAL WOOL INSULATION
VAPOR RETARDER,
SEAL TO FLOOR AND CEILING
BASE, SEE FINISH SCHEDULE
EXISTING CEILING
3 5 8" LIGHT GAUGE METAL
FRAMING
GWB SOFFIT BEYOND.
PATCH AND PAINT
EXISTING SOFFIT
±1
1
'
-
8
"
V
.
I
.
F
.
±9
'
-
0
"
FIRST
FLOOR
EXISTING MASONRY
WALL
1,4,5 TYPICAL
03
LIGHT GAUGE METAL
FRAMING AND 5/8"
GWB, PAINT
PROVIDE TRIM TO
MATCH EXISTING.
TYPICAL
EXISTING MASONRY
WALL
5 8" GWB, PAINT
EXISTING 3 5 8" LIGHT GAUGE
METAL FRAMING. V.I.F THAT
FRAMING EXTENDS TO THE
STRUCTURE ABOVE.
FINISH FLOOR
BASE, SEE FINISH SCHEDULE
MINERAL WOOL INSULATION
VAPOR RETARDER,
SEAL TO FLOOR AND CEILING
±1
2
'
-
0
"
±9
'
-
0
"
FIRST
FLOOR
AS REQUIRED,
ASSUME 3'
STRUCTURE ABOVE
3'-0" V.I.F
EXISTING
CEILING, PAINT
02
LIGHT GAUGE METAL
FRAMING AND 5/8" GWB,
ALIGN WITH EXISTING CEILING
PROVIDE SMOOTH
TRANSITION. PAINT
EXISTING MASONRY
WALL
5 8" GWB, PAINT
2" HAT CHANNEL
FINISH FLOOR
BASE, SEE FINISH SCHEDULE
MINERAL WOOL INSULATION
VAPOR RETARDER,
SEAL TO FLOOR AND CEILING
LIGHT GAUGE METAL
FRAMING AND 5/8" GWB,
ALIGN WITH EXISTING CEILING
PROVIDE SMOOTH
TRANSITION. PAINT
EXISTING
CEILING, PAINT
±1
2
'
-
0
"
±9
'
-
0
"
FIRST
FLOOR
3'-0" V.I.F
AS REQUIRED,
ASSUME 3'
STRUCTURE ABOVE
01
SHEET OF
SHEET NUMBER
SHEET TITLE
PROJECT NUMBER
PROJECT
NORTH
CONSULTANT
It is a violation of the New York State Education
Law, Article 145 Sec. 7209, for any person
unless he is acting under the direction of a
licensed professional Architect, Engineer or
Land Surveyor to alter an item in any way. If an
item bearing the seal of an Architect, Engineer
or Land Surveyor is altered, the altering
Architect, Engineer or Land Surveyor shall affix
to the item his seal and the notation "altered by"
followed by his signature and the date of such
alteration, and a specific description of the
alteration.
PROJECT
11
/
7
/
2
0
2
5
1
1
:
4
7
:
0
9
A
M
/HE
A
T
H
E
R
V
E
N
D
I
T
T
I
Fax (315) 487 - 5947
Tel (315) 488 - 0377
215 Wyoming Street
info@bellandspina.com
www.bellandspina.com
Fax (585) 487 - 9532
Suite 200
Tel (585) 200 - 5038
1163 Pittsford-Victor Rd
DATEMARK DESCRIPTION
The Contractor shall verify all dimensions and
notify the Architect in writing of any
discrepancies.
All drawings and specifications are the
property of the Architect and shall be used
only on the job designated.
CHECKED
SCALE
DRAWN
DATE
AS NOTED
Syracuse, NY 13204Pittsford, NY 14534
Suite 201
WALL SECTIONS
AND DETAILS
A-301
10/24/2025
HHV DE
716-23-002
TO
W
N
O
F
I
T
H
A
C
A
2
N
D
F
L
O
O
R
&
C
O
U
R
T
O
F
F
I
C
E
R
E
N
O
V
A
T
I
O
N
TO
W
N
O
F
I
T
H
A
C
A
T
O
W
N
H
A
L
L
21
5
N
O
R
T
H
T
I
O
G
A
S
T
R
E
E
T
IT
H
A
C
A
,
N
Y
Cl
i
e
n
t
P
r
o
j
e
c
t
N
o
:
A
A
1
6
2
0
.
5
1
7
3112
BID DOCUMENTS
SCALE:3/4" = 1'-0"4 WALL SECTION @ OFFICE 109 AND 110
SCALE:3/4" = 1'-0"3 WALL SECTION @ OFFICE 107
SCALE:3/4" = 1'-0"2 WALL SECTION @ SOFFIT ROOM 109 AND 110
SCALE:3/4" = 1'-0"5 WALL SECTION @ ROOM 104
SCALE:3/4" = 1'-0"1 WALL SECTION @ ROOM 103
PHOTO 3 WINDOW WELL OFFICE 107PHOTO 1 WINDOW WELL OFFICE 110 PHOTO 4 WINDOW WELL OFFICE 109PHOTO 2 WINDOW OFFICE 110 PHOTO 5 WINDOW WELL OFFICE 109
PHOTO 6 WINDOW WELL OFFICE 107
PHOTO 7 REST ROOM 104
SEE 8/A-101 SEE 8/A-101
SEE 8/A-101
SEE 8/A-101
REGISTRATION EXPIRES: 08/31/2028
105
CORRIDOR
3
STAIR
105-1
07
3-1
CABINET
2'-73 4"6'-0"
8'-73 4"
2'
-
0
"
1'
-
1
3
4"
TRANSACTION
WINDOW
UNDERMOUNT SHELVING
BRACKETS 16" O.C., TYP.
SOLID SURFACE
COUNTER TOP
BULLET-RESISTANT
FIBERGLASS
PANEL
DOOR
OPERATOR
BUTTON.
DOOR 107-1
102
CORRIDOR
3'
-
8
"
08
HINGED
ACCESS
COVER
GROMMET
PROVIDE BLOCKING FOR
WALL-MOUNTED MONITOR BY
OWNER
1'
-
1
1
"
A-501
9
A-501
8A-501
5
2'-73 4"6'-0"
8'-73 4"
8'
-
1
1
"
CABINET PAINT
TRANSACTION
WINDOW
SOLID SURFACE
COUNTER TOP
1"
2'-812"
3'
-
0
"
PROVIDE BLOCKING FOR
WALL-MOUNTED MONITOR
(BY OWNER)
BASE, SEE FINISH
SCHEDULE
TRANSACTION
DRAWER
COUNTER TOP SUPPORT
BRACKETS @ 18" O.C. PAINT
TO MATCH WALL. PROVIDE
BLOCKING AS REQ'D
SOLID SURFACE
COUNTERTOP
GWB, PAINT
BASE, SEE
FINISH
SCHDULE
2'
-
8
3
4"
2'-812"
A-501
7
COUNTER TOP SUPPORT
BRACKETS @ 18" O.C., PAINT TO
MATCH WALL. DO NOT IMPEDE
OPERATION OF TRANSACTION
DRAWER. PROVIDE BLOCKING
AS REQ'D.
TRANSACTION
WINDOW
TRANSACTION
DRAWER
2
4
2
4
CABINET BACK 1 2" PLYWOOD
WITH WOOD VENEER LAMINATE
ONE SIDE AND BACKER AT 1 2 X 21 2"
SOLID HARDWOOD BLOCKING.
ANCHOR CASEWORK TO THE WALL
3/4" PLYWOOD,
WITH WOOD
VENEER LAMINATE
ADJUSTABLE SHELF,
1/2" PLYWOOD, WITH
WOOD VENEER
LAMINATE
ALL SIDES
EXISTING CEILING
CABINET TOP AND
SIDES, 3/4" PLYWOOD,
WITH WOOD VENEER
LAMINATE
2'-0"BLOCKING AS
REQ'D.
1 X TRIM, FINISH TO MATCH
CABINET VENEER
5
44
NAILER
A-501
6
312"
8'
-
7
1
2"
8'
-
1
1
"
4'
-
3
3
4"
4'
-
3
3
4"
3/4" PLYWOOD,
WITH WOOD
VENEER LAMINATE
1 2" SOLID SURFACE TOP AND
SOLID SURFACE NOSING WITH
PLYWOOD BASE. COORDINATE
CUTOUT FOR TRANSACTION
DRAWER ACCESS AND VIEW
PANEL.
TRANSACTION DRAWER
U.L. RATED BULLET
RESISTANT GLAZING,
SEE SPEC.
1 3/4 " X 4" ALUMINUM TUBE
WINDOW FRAME
107
OFFICE
105
CORRIDOR
WALL TYPE
SEE A-001
CONTINUOUS 1 2"
BULLET-RESISTANT
FIBERGLASS
PANEL
BOX BEAM LINTEL
LIGHT GAUGE METAL
FRAMING, SUPPORTING
TRANSACTION DRAWER
FINISH FLOOR
ALUMINUM U-CHANNEL
ALUMINUM U-CHANNEL
07
5 8" GWB
5 8" GWB
3'
-
0
"
2'
-
8
3
4"
A-501
2
BASE, SEE
FINISH
SCHEDULE
A-501
1
A-501
3
WALL TYPE
SEE A-001
07
8"2'-0"
1 3/4 " X 4" ALUMINUM TUBE
WINDOW FRAME
ALUMINUM U-CHANNEL
U.L. RATED BULLET-RESISTANT
GLAZING BAFFLE WINDOW
#10 - 3 1 2" FHP SCREWS TO
SECURE FRAME IN OPENING
512"
SEALANT ALL SIDES, TYP.
1
3
4"
LIGHT GAUGE METAL BOX
BEAM HEADER. FILL WITH
INSULATION
SEALANT ALL SIDES, TYP.
#10 - 3 1 2" FHP SCREWS TO
SECURE FRAME IN OPENING
ALUMINUM U-CHANNEL
U.L.RATED BULLET-RESISTANT
VERTICAL BAFFLE
TRANSACTION WINDOW
1 3 4" X 4" ALUMINUM TUBE
512"
5 8" GWB, TYP.
SHIM
1 2" CONTINUOUS
BULLET-RESISTANT
FIBERGLASS PANEL
LIGHT GAUGE METAL
FRAMING. SEE WALL TYPE
07. FILL KING AND JACK
STUDS WITH INSULATION
1
2"
ALUMINUM U-CHANNEL
1 2" SOLID SURFACE TOP AND 3 4
SOLID SURFACE NOSING WITH 1 2"
PLYWOOD BASE. CUT FOR
TRANSACTION DRAWER LID,
BEYOND
TRANSACTION DRAWER
U.L. RATED BULLET-RESISTANT
GLAZING BAFFLE WINDOW
612"
SHEET OF
SHEET NUMBER
SHEET TITLE
PROJECT NUMBER
PROJECT
NORTH
CONSULTANT
It is a violation of the New York State Education
Law, Article 145 Sec. 7209, for any person
unless he is acting under the direction of a
licensed professional Architect, Engineer or
Land Surveyor to alter an item in any way. If an
item bearing the seal of an Architect, Engineer
or Land Surveyor is altered, the altering
Architect, Engineer or Land Surveyor shall affix
to the item his seal and the notation "altered by"
followed by his signature and the date of such
alteration, and a specific description of the
alteration.
PROJECT
11
/
7
/
2
0
2
5
1
1
:
4
7
:
2
9
A
M
/HE
A
T
H
E
R
V
E
N
D
I
T
T
I
Fax (315) 487 - 5947
Tel (315) 488 - 0377
215 Wyoming Street
info@bellandspina.com
www.bellandspina.com
Fax (585) 487 - 9532
Suite 200
Tel (585) 200 - 5038
1163 Pittsford-Victor Rd
DATEMARK DESCRIPTION
The Contractor shall verify all dimensions and
notify the Architect in writing of any
discrepancies.
All drawings and specifications are the
property of the Architect and shall be used
only on the job designated.
CHECKED
SCALE
DRAWN
DATE
AS NOTED
Syracuse, NY 13204Pittsford, NY 14534
Suite 201
ENLARGED FLOOR
PLAN, SECTION AND
DETAILS
A-501
10/24/2025
HHV DE
716-23-002
TO
W
N
O
F
I
T
H
A
C
A
2
N
D
F
L
O
O
R
&
C
O
U
R
T
O
F
F
I
C
E
R
E
N
O
V
A
T
I
O
N
TO
W
N
O
F
I
T
H
A
C
A
T
O
W
N
H
A
L
L
21
5
N
O
R
T
H
T
I
O
G
A
S
T
R
E
E
T
IT
H
A
C
A
,
N
Y
Cl
i
e
n
t
P
r
o
j
e
c
t
N
o
:
A
A
1
6
2
0
.
5
1
7
3113
BID DOCUMENTS
SCALE:1/2" = 1'-0"10 ENLARGED PLAN AT TRANSACTION WINDOW
SCALE:1/2" = 1'-0"8 ELEVATION
SCALE:1/2" = 1'-0"9 ELEVATION
SCALE:1" = 1'-0"5 CABINET DETAIL
SCALE:1" = 1'-0"6 CABINET ELEVATION
SCALE:1" = 1'-0"7 SECTION @ TRANSACTION WINDOW
SCALE:3" = 1'-0"1 TRANSACTION WINDOW HEAD DETAIL
SCALE:3" = 1'-0"2 TRANSACTION WINDOW JAMB DETAIL
SCALE:3" = 1'-0"3 TRANSACTION WINDOW SILL DETAIL
REGISTRATION EXPIRES: 08/31/2028
EAST BUFFALO STREET
1910
NO
R
T
H
T
I
O
G
A
S
T
R
E
E
T
1910
1935
1965
POST OFFICE
N.I.C.
1935
1965 OR LATER
A
A-600
B
A-600
C
A-600
RESTORED
4A4
W12
NEW REPLICA
±
2
'
-
1
1
"
±1'-11"
PAINT WOOD
SASH, FRAME &
TRIM, PT-6, TYP.
ATTIC WINDOW AT WALL CAP
4B
W13
RESTORED & MODIFIED
MECHANICAL EXHAUST
IN CENTER PANE
±
2
'
-
1
1
"
±1'-11"
PAINT WOOD
SASH, FRAME &
TRIM, PT-6, TYP.
SHEET OF
SHEET NUMBER
SHEET TITLE
PROJECT NUMBER
PROJECT
NORTH
CONSULTANT
It is a violation of the New York State Education
Law, Article 145 Sec. 7209, for any person
unless he is acting under the direction of a
licensed professional Architect, Engineer or
Land Surveyor to alter an item in any way. If an
item bearing the seal of an Architect, Engineer
or Land Surveyor is altered, the altering
Architect, Engineer or Land Surveyor shall affix
to the item his seal and the notation "altered by"
followed by his signature and the date of such
alteration, and a specific description of the
alteration.
PROJECT
11
/
7
/
2
0
2
5
1
1
:
5
0
:
4
8
A
M
/HE
A
T
H
E
R
V
E
N
D
I
T
T
I
Fax (315) 487 - 5947
Tel (315) 488 - 0377
215 Wyoming Street
info@bellandspina.com
www.bellandspina.com
Fax (585) 487 - 9532
Suite 200
Tel (585) 200 - 5038
1163 Pittsford-Victor Rd
DATEMARK DESCRIPTION
The Contractor shall verify all dimensions and
notify the Architect in writing of any
discrepancies.
All drawings and specifications are the
property of the Architect and shall be used
only on the job designated.
CHECKED
SCALE
DRAWN
DATE
AS NOTED
Syracuse, NY 13204Pittsford, NY 14534
Suite 201
KEY PLAN AND
ELEVATIONS
A-601
10/24/2025
HHV DE
716-23-002
TO
W
N
O
F
I
T
H
A
C
A
2
N
D
F
L
O
O
R
&
C
O
U
R
T
O
F
F
I
C
E
R
E
N
O
V
A
T
I
O
N
TO
W
N
O
F
I
T
H
A
C
A
T
O
W
N
H
A
L
L
21
5
N
O
R
T
H
T
I
O
G
A
S
T
R
E
E
T
IT
H
A
C
A
,
N
Y
Cl
i
e
n
t
P
r
o
j
e
c
t
N
o
:
A
A
1
6
2
0
.
5
1
7
3114
BID DOCUMENTS
SCALE:1/16" = 1'-0"3 KEY ROOF PLAN'C' WEST ELEVATION
'B' PARTIAL SOUTH ELEVATION
'A' NORTH ELEVATION
SCOPE OF WORK SUMMARY
INTENT OF THIS PROJECT IS TO RESTORE AND WEATHER SEAL
WINDOWS CONSISTENT WITH THE SECRETARY OF THE INTERIOR
STANDARDS FOR THE TREATMENTS OF HISTORIC PROPERTIES.
ITEM #1 - WINDOWS IN THE 1910 HISTORICALLY SIGNIFICANT SECTION
OF THE BUILDING SHALL BE RESTORED, EXCLUDING THE BASEMENT.
OPERABLE SASHES TO BE REMOVED, LOOSE PAINT CAREFULLY
SCRAPED, SASHES REPAIRED OR REPLACED WITH WOOD
DUTCHMANS AS NECESSARY TO MATCH THE EXISTING. EXISTING
SINGLE PANE GLAZING TO BE REPLACED WITH NEW CLEAR LOW IRON
GLASS IGU (WITH LOW-E COATING). WITHIN THE COURT OFFICES AND
RESTROOMS APPLY NEW INTERIOR PRIVACY FILM. SASH WEIGHTS TO
BE REMOVED AND THE WEIGHT POCKETS FILLED WITH LOW RISE
EXPANDING FOAM TO AIR SEAL. SINGLE AND DOUBLE HUNG UNITS
WILL BE MADE FIXED UNITS. SASHES WILL BE AIR SEALED WITH NEW
CONCEALED MASTIC. EXTERIOR AND INTERIOR WOOD FRAMES TO BE
PAINTED TO MATCH WITH NEW SEALANTS INSTALLED AROUND THE
PERIMETER. REFER TO TYPICAL WINDOW DETAILS ON A-701.
INTERIOR CASING TRIM TO BE REPLACED IN KIND.
#2 - NOT USED
#3 - REMOVE AND REPLACE THE EXISTING WOOD WINDOW, FRAME
AND SASH WITH NEW WOOD WINDOW TO MATCH ORIGINAL.
#4 - ATTIC WINDOW. SASHES TO BE REMOVED, LOOSE PAINT
CAREFULLY SCRAPED, SASHES REPAIRED OR REPLACED WITH WOOD
DUTCHMANS AS NECESSARY TO MATCH THE EXISTING. EXISTING
SINGLE PANE GLAZING TO BE REPLACED WITH NEW CLEAR LOW-IRON
GLASS IGU (WITH LOW-E COATING). EXTERIOR AND INTERIOR WOOD
FRAMES TO BE PAINTED TO MATCH WITH NEW SEALANTS INSTALLED
AROUND THE PERIMETER.
#4A - ATTIC WINDOW. REMOVE EXISTING
LOUVER AND REPLACE WITH NEW SASH TO MATCH ORIGINAL WITH
NEW CLEAR LOW-IRON GLASS IGU (WITH LOW-E COATING). EXTERIOR
AND INTERIOR WOOD FRAMES TO BE PAINTED TO MATCH WITH NEW
SEALANTS INSTALLED AROUND THE PERIMETER.
#4B - CENTER PANE TO BE CONVERTED FOR MECHANICAL
INTAKE/EXTRACT. COORDINATE WITH M-SERIES. SASH TO BE
REMOVED AND REPLACED WITH NEW SASH TO MATCH ORIGINAL WITH
NEW CLEAR LOW-IRON GLASS IGU (WITH LOW-E COATING). LOOSE
PAINT CAREFULLY SCRAPED, SASH REPAIRED OR REPLACED WITH
WOOD DUTCHMANS AS NECESSARY TO MATCH THE EXISTING.
EXTERIOR AND INTERIOR WOOD FRAMES TO BE PAINTED TO MATCH
THE EXISTING. INSTALL SEALANT AT PERIMETER FOR AIRTIGHTNESS.
1
2
3
4
4A
3
3
4B
1
N.I.C
N.I.C
4B
4
4
4
4A
4A
4B
444
GLAZING TO HAVE PRIVACY
FILM APPLIED
1
1111
GLAZING TO HAVE PRIVACY
FILM APPLIED
11
4B
N.I.C
N.I.C.N.I.C.N.I.C.
N.I.C.N.I.C.N.I.C.N.I.C.
N.I.C.N.I.C.
SCALE:1/2" = 1'-0"1 ATTIC WINDOW ELEVATION
SCALE:1/2" = 1'-0"2 ATTIC @ WALL CAP
REFER TO SCOPE ITEM #4 AND #4A
N.I.C
N.I.C
REGISTRATION EXPIRES: 08/31/2028
20
'
-
2
"
2'
-
7
"
V
.
I
.
F
.
8'
-
3
"
V
.
I
.
F
.
2'
-
9
"
V
.
I
.
F
.
4'
-
1
1
2"
V
.
I
.
F
.
7'-2" V.I.F.
11
'
-
0
"
V
.
I
.
F
EXISTING
1
W8 W7 W8
W6 W5 W6
PAINT WOOD SASH,
FRAME & TRIM, PT-1, TYP.
20
'
-
2
"
7'-2" V.I.F.
2'
-
6
1
4"
V
.
I
.
F
.
8'
-
3
"
V
.
I
.
F
.
2'
-
9
"
V
.
I
.
F
.
4'
-
1
12"
V
.
I
.
F
.
11
'
-
0
"
V
.
I
.
F
EXISTING
1
W8 W7 W8
W6 W5 W6
PAINT WOOD SASH,
FRAME & TRIM, PT-6, TYP.
INTERIOREXTERIOR
2'
-
1
1
3
4"V
.
I
.
F
.
1'-0"V.I.F.
1"
1"
NEW
W11 W11
PAINT WOOD SASH,
FRAME & TRIM,
PT-6, TYP.
FRAME & TRIM,
TYP. SEE FINISH
SCHEDULE
SHEET OF
SHEET NUMBER
SHEET TITLE
PROJECT NUMBER
PROJECT
NORTH
CONSULTANT
It is a violation of the New York State Education
Law, Article 145 Sec. 7209, for any person
unless he is acting under the direction of a
licensed professional Architect, Engineer or
Land Surveyor to alter an item in any way. If an
item bearing the seal of an Architect, Engineer
or Land Surveyor is altered, the altering
Architect, Engineer or Land Surveyor shall affix
to the item his seal and the notation "altered by"
followed by his signature and the date of such
alteration, and a specific description of the
alteration.
PROJECT
11
/
7
/
2
0
2
5
1
1
:
5
1
:
0
8
A
M
/HE
A
T
H
E
R
V
E
N
D
I
T
T
I
Fax (315) 487 - 5947
Tel (315) 488 - 0377
215 Wyoming Street
info@bellandspina.com
www.bellandspina.com
Fax (585) 487 - 9532
Suite 200
Tel (585) 200 - 5038
1163 Pittsford-Victor Rd
DATEMARK DESCRIPTION
The Contractor shall verify all dimensions and
notify the Architect in writing of any
discrepancies.
All drawings and specifications are the
property of the Architect and shall be used
only on the job designated.
CHECKED
SCALE
DRAWN
DATE
AS NOTED
Syracuse, NY 13204Pittsford, NY 14534
Suite 201
WINDOW
ELEVATIONS
A-602
10/24/2025
HHV DE
716-23-002
TO
W
N
O
F
I
T
H
A
C
A
2
N
D
F
L
O
O
R
&
C
O
U
R
T
O
F
F
I
C
E
R
E
N
O
V
A
T
I
O
N
TO
W
N
O
F
I
T
H
A
C
A
T
O
W
N
H
A
L
L
21
5
N
O
R
T
H
T
I
O
G
A
S
T
R
E
E
T
IT
H
A
C
A
,
N
Y
Cl
i
e
n
t
P
r
o
j
e
c
t
N
o
:
A
A
1
6
2
0
.
5
1
7
3115
BID DOCUMENTS
SCALE:1/2" = 1'-0"5 1910 WINDOW INTERIOR ELEVATION AT LOBBY
SCALE:1/2" = 1'-0"4 1910 WINDOW EXTERIOR WEST ELEVATION
SCALE:1" = 1'-0"1 1910 SMALL WINDOW ELEVATION
WEST ELEVATIONSOUTH ELEVATION
SMALL
WINDOW
SEE 1/A-101
NOTES:
- CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS
- BUILDING IS ON THE NATIONAL REGISTER. VINTAGES FROM
1910 & 1935 ARE CONSIDERED SIGNIFICANT.
REFER TO SCOPE ITEM #1 AND #2
REFER TO SCOPE ITEM #3
3
3
SCOPE OF WORK SUMMARY
ITEM #1 AND #2 - WINDOWS IN THE 1910 HISTORICALLY SIGNIFICANT
SECTION OF THE BUILDING SHALL BE RESTORED. OPERABLE SASHES
TO BE REMOVED, LOOSE PAINT CAREFULLY SCRAPED, SASHES
REPAIRED OR REPLACED WITH WOOD DUTCHMANS AS NECESSARY
TO MATCH THE EXISTING. EXISTING SINGLE PANE GLAZING TO BE
REPLACED WITH NEW CLEAR LOW IRON GLASS IGU (WITH LOW E
COATING). WITHIN THE COURT OFFICES AND RESTROOMS APPLY NEW
INTERIOR PRIVACY FILM. SASH WEIGHTS TO BE REMOVED AND THE
WEIGHT POCKETS FILLED WITH LOW RISE EXPANDING FOAM FOR AIR
SEAL. HUNG SINGLE AND DOUBLE HUNG UNITS WILL BE MADE FIXED
UNITS. SASHES WILL BE AIR SEALED WITH NEW CONCEALED MASTIC.
EXTERIOR AND INTERIOR WOOD FRAMES TO BE PAINTED TO MATCH
EXISTING WITH NEW SEALANTS INSTALLED AROUND THE PERIMETER.
REFER TO TYPICAL WINDOW DETAILS ON A701.
THE SCOPE OF THIS PROJECT INCLUDES INTERIOR SIDE INSULATION
UPGRADES AND NEW WALL FURRING. INTERIOR TRIM TO BE
REPLACED IN KIND.
#3 - REMOVE AND REPLACE THE EXISTING WOOD WINDOW, FRAME
AND SASH WITH NEW WOOD WINDOW TO MATCH EXISTING SIGHTLINES.
2
3
1
REGISTRATION EXPIRES: 08/31/2028
EXISTING MASONRY
WALL
EXISTING STONE
SILL
WOOD STOOL,
MATCH EXISTING
PAINT
WOOD TRIM
MATCH EXISTING,
PAINT
REPLACEMENT
7 16" IGU
GWB, PAINT
WALL ASSEMBLY
SEE 1/A-001
WOOD TRIM
MATCH EXISTING,
PAINT
VAPOR RETARDER,
SEAL TO WINDOW
FRAME
GLAZING PUTTY
INTERIOR STOP TO
BE ROUTED BACK
TO RECEIVE IGU
± 10" V.I.F.
FRAME TO REMAIN
RESTORED SASH
03
GWB, PAINT
WALL ASSEMBLY
SEE 1/A-001
PROVIDE WOOD
TRIM MATCH
EXISTING, PAINT
EXTENSION
JAMB, PAINT
REPLACEMENT
7 16" IGU
PROVIDE WOOD
TRIM MATCH
EXISTING, PAINT
FILL WEIGHT
POCKETS W/ CCSF
FOR AIR TIGHTNESS
EXISTING MASONRY
WALL
VAPOR RETARDER,
SEAL TO WINDOW
FRAME
EXISTING STONE
SILL, BEYOND
GLAZING PUTTY
INTERIOR STOP TO
BE ROUTED BACK
TO RECEIVE IGU
FRAME TO
REMAIN
RESTORED SASH
03
GWB, PAINT
WALL ASSEMBLY
SEE 1/A-001
PROVIDE WOOD
TRIM MATCH
EXIST., PAINT
EXTENSION
JAMB, PAINT
FILL WEIGHT
POCKETS W/ CCSF
FOR AIR TIGHTNESS
PROVIDE WOOD TRIM
MATCH EXISTING,
PAINT
EXISTING MASONRY
WALL
VAPOR RETARDER,
SEAL TO M.O.
REPLACEMENT
IGU
GLAZING PUTTY INTERIOR STOP TO
BE ROUTED BACK
TO RECEIVE IGU
±7
3
4"
V
.
I
.
F
.
FRAME TO REMAIN
RESTORED SASH
03
1
2"3'-0"2"
2"
7'
-
0
"
A-701
2
A-701
6
A-701
4
A-701
8
A-701
3
A-701
7
6"
H.M. FRAME,
PAINT
SEALANT ALL
SIDES
EXISTING
WALL
6"
JAMB ANCHOR
(3 PER JAMB, TYP.)
SEALANT ALL
SIDES, TYP.
H.M. FRAME, PAINT
2"
EXISTING WALL
DO NOT DISTURB
MARBLE IN LOBBY
7'
-
0
"
3'-0"
A B
7'
-
0
"
3'-0"
7'
-
0
"
2'-6"
C
G-1
1'-10"
1'
-
1
1
"
±7
'
-
6
"
±7
'
-
6
"
±3'-10"±1'-5"±2'-2"±1'-5"
±7
'
-
7
"
±7
'
-
7
"
±3'-10"±1'-5"±2'-7"±1'-5"
±3
'
-
4
12"
±3
'
-
1
3
4"
±3
'
-
2
"
±2
'
-
1
0
3
4"± R
3
'
-
6
14"
±
R
3
'
-
1
1
4"
±
R
3
'
-
6
14"
± R3'-
1
14"
±2
'
-
1
0
1
2"
±2'-3"
W8W7W4W3 W12
W6W5W2W1
1
±2
'
-
1
0
12"
±2'-3"
W13
WALL CAPS FOR NEW AIR
TERMINALS. COORDINATE
WITH M-SERIES
IG-1 IG-1 IG-1 IG-1
IG-1
IG-1
IG-1
IG-1
IG-1
IG-1
IG-1
IG-1
F-1
F-1
F-1
F-1 F-1
F-1
IG-1
IG-1
F-1
F-1
REPLACEMENT
IGUHEAD
EXISTING
MASONRY
WALL
MINERAL WOOL
INSULATION
SMART VAPOR
RETARDER SEAL
TO WINDOW FRAME
SILL
REPLACEMENT
IGU
EXISTING
MASONRY WALL
MINERAL WOOL
INSULATION
SMART VAPOR
RETARDER
EXISTING
MASONRY WALL
JAMB
REPLACEMENT
IGU
MINERAL WOOL
INSULATION
SMART VAPOR
RETARDER SEAL
TO WINDOW FRAME
SEALANT
H.M. FRAME,
FILL WITH MINERAL
WOOL INSULATION
5 8" GWB TO
EXTEND TO
CEILING
5 8" GWB
PAINT.PROVIDE
SMOOTH TRANSITION
TO EXISTING WALL.
LIGHT GAUGE METAL BOX
BEAM
SEALANT
1 2" BULLET-
RESISTANT
FIBERGLASS
PANEL, EXTEND TO
CEILING
V.I.F.
±
6
"
EXISTING WALL
V.
I
.
F
.
DOOR SEE
SCHED.
±73 4" V.I.F.
V.
I
.
F
.
± 6"
SEE PLAN
±7
3
4"
V
.
I
.
F
.
DOOR SEE
SCHED.5 8" GWB, PAINT
SEALANT, TYP.
1 2" BULLET-RESITANT
FIBERGLASS PANEL
2"
EXISTING
WALL
5 8" GWB, PAINT.
PROVIDE SMOOTH
TRANSITION TO
EXISTING WALL
PROVIDE
J BEAD
TRIM
DOOR SEE
SCHED.
H.M. FRAME
ANCHOR TO
LIGHT GAUGE
METAL
PARTITION
5 8' GWB, PAINT
LIGHT GAUGE METAL
BOX BEAM
SEALANT BOTH
SIDES
DOOR, SEE
SCHED.
H.M. FRAME
ANCHOR TO
LIGHT GAUGE
METAL PARTITION
SEALANT BOTH
SIDES
5 8' GWB, PAINT
LIGHT GAUGE METAL
BOX BEAM
SHIM
DOOR, SEE
SCHED.
REINSTALL
EXISTING FRAME
TRIM, MATCH IN KIND.
PAINT BOTH SIDES
EXISTING WALL
2 2X6 AND
BLOCKING
5 8" GWB, PAINT.
PROVIDE SMOOTH
TRANSITION WITH
EXISTING WALL
1 2" SHIM
2
6
2
6
2
4
2
4
DOOR, SEE
SCHED.
TRIM, MATCH IN KIND.
PAINT BOTH SIDES
5 8" GWB
PROVIDE SMOOTH
TRANSITION WITH EXISING
WALL. BOTH SIDES
2 2X4
EXISTING WALL
1 2" SHIM
REINSTALL
EXISTING FRAME
±2
'
-
1
1
3
4"
VI
F
W11
IG-1
IG-1
F-1
F-1
1'-0"
VIF
3'
-
0
3
4"
R
O
,
V
I
F
1'-1" RO,
VIF
SHEET OF
SHEET NUMBER
SHEET TITLE
PROJECT NUMBER
PROJECT
NORTH
CONSULTANT
It is a violation of the New York State Education
Law, Article 145 Sec. 7209, for any person
unless he is acting under the direction of a
licensed professional Architect, Engineer or
Land Surveyor to alter an item in any way. If an
item bearing the seal of an Architect, Engineer
or Land Surveyor is altered, the altering
Architect, Engineer or Land Surveyor shall affix
to the item his seal and the notation "altered by"
followed by his signature and the date of such
alteration, and a specific description of the
alteration.
PROJECT
11
/
7
/
2
0
2
5
1
1
:
5
2
:
0
4
A
M
/HE
A
T
H
E
R
V
E
N
D
I
T
T
I
Fax (315) 487 - 5947
Tel (315) 488 - 0377
215 Wyoming Street
info@bellandspina.com
www.bellandspina.com
Fax (585) 487 - 9532
Suite 200
Tel (585) 200 - 5038
1163 Pittsford-Victor Rd
DATEMARK DESCRIPTION
The Contractor shall verify all dimensions and
notify the Architect in writing of any
discrepancies.
All drawings and specifications are the
property of the Architect and shall be used
only on the job designated.
CHECKED
SCALE
DRAWN
DATE
AS NOTED
Syracuse, NY 13204Pittsford, NY 14534
Suite 201
WINDOW AND DOOR
DETAILS AND DOOR
AND FRAME TYPES
A-701
10/24/2025
HHV DE
716-23-002
TO
W
N
O
F
I
T
H
A
C
A
2
N
D
F
L
O
O
R
&
C
O
U
R
T
O
F
F
I
C
E
R
E
N
O
V
A
T
I
O
N
TO
W
N
O
F
I
T
H
A
C
A
T
O
W
N
H
A
L
L
21
5
N
O
R
T
H
T
I
O
G
A
S
T
R
E
E
T
IT
H
A
C
A
,
N
Y
Cl
i
e
n
t
P
r
o
j
e
c
t
N
o
:
A
A
1
6
2
0
.
5
1
7
3116
BID DOCUMENTS
SCALE:1 1/2" = 1'-0"11 TYPICAL WINDOW SILL DETAIL
SCALE:1 1/2" = 1'-0"10 TYPICAL WINDOW JAMB DETAIL
SCALE:1 1/2" = 1'-0"1 TYPICAL WINDOW HEAD DETAIL
SCALE:1/4" = 1'-0"16 DOOR TYPES
SCALE:3" = 1'-0"2 HEAD DETAIL
SCALE:3" = 1'-0"6 JAMB DETAIL
SCALE:1/4" = 1'-0"14 WINDOW SASH TYPES
SCALE:1 1/2" = 1'-0"12 ATTIC WINDOW DETAILS
EXISTING WINDOW
FRAME
AREA OF MODIFICATION:
INTERIOR STOP TO BE ROUTED
BACK APPROX. 5 16" TO 3 8" TO
RECEIVE IGU
V.I.F ALL DIMENSIONS
SCALE:3" = 1'-0"3 HEAD DETAIL DOOR 107-1
SCALE:3" = 1'-0"7 JAMB DETAIL DOOR 107-1
SCALE:3" = 1'-0"4 HEAD DETAIL DOOR MO2-2
SCALE:3" = 1'-0"8 JAMB DETAIL DOOR MO2-2
SCALE:3" = 1'-0"5 HEAD DETAIL DOOR MO2A-1
SCALE:3" = 1'-0"9 JAMB DETAIL DOOR MO2A-1
SCALE:1/4" = 1'-0"13 WINDOW TYPE
SCALE:1/4" = 1'-0"15 FRAME TYPE
NOTE: PATCH ALL HOLES
MADE FROM SPRAY FOAM, TYPICAL.
FINISH TO MATCH SURROUNDING
REGISTRATION EXPIRES: 08/31/2028
RECIRCULATION
HOT
COLD
VENT
WASTE BELOW FLOOR
WASTE
SHEET OF
SHEET NUMBER
SHEET TITLE
PROJECT NUMBER
PROJECT
NORTH
CONSULTANT
It is a violation of the New York State Education
Law, Article 145 Sec. 7209, for any person
unless he is acting under the direction of a
licensed professional Architect, Engineer or
Land Surveyor to alter an item in any way. If an
item bearing the seal of an Architect, Engineer
or Land Surveyor is altered, the altering
Architect, Engineer or Land Surveyor shall affix
to the item his seal and the notation "altered by"
followed by his signature and the date of such
alteration, and a specific description of the
alteration.
PROJECT
2/
2
6
/
2
0
2
5
1
:
4
8
:
5
5
P
M
/CH
R
I
S
B
A
C
A
Fax (315) 487 - 5947
Tel (315) 488 - 0377
215 Wyoming Street
info@bellandspina.com
www.bellandspina.com
Fax (585) 487 - 9532
Suite 200
Tel (585) 200 - 5038
1163 Pittsford-Victor Rd
DATEMARK DESCRIPTION
The Contractor shall verify all dimensions and
notify the Architect in writing of any
discrepancies.
All drawings and specifications are the
property of the Architect and shall be used
only on the job designated.
CHECKED
SCALE
DRAWN
DATE
AS NOTED
Syracuse, NY 13204 Pittsford, NY 14534
Suite 201
0 5
716-23-002
TO
W
N
O
F
I
T
H
A
C
A
2
N
D
F
L
.
M
E
Z
Z
A
N
I
N
E
&
C
O
U
R
T
O
F
F
I
C
E
R
E
N
O
V
A
T
I
O
N
TO
W
N
O
F
I
T
H
A
C
A
T
O
W
N
H
A
L
L
21
5
N
O
R
T
H
T
I
O
G
A
S
T
R
E
E
T
IT
H
A
C
A
,
N
Y
Cl
i
e
n
t
P
r
o
j
e
c
t
N
o
:
BID DOCUMENTS
110 SOUTH ALBANY STREET
ITHACA, NEW YORK 14850
PH: 607-277-1118
BALL VALVE CLOSED
VENT THRU ROOF
BALL VALVE OPEN
CHECK VALVE
THERMOMETER
CIRCULATOR
CONNECT TO EXISTING
LEGEND & NOTES
GS YB
PLUMBING FIXTURE SCHEDULE
MARK MANUF MODEL DESCRIPTION NOTES
WC-1 AMERICAN STANDARD 215AA.104 ELONGATED BOTTOM OUTLET TWO-PIECE ADA FLUSH TANK TOILET, 1.28 GPF, EPA WATER SENSE, 1000G MAP
SCORE, WITH CHAIR HEIGHT BOWL PROVIDE WITH WC-1.1
WC-1.1 AMERICAN STANDARD 5901.110 ELONGATED HEAVY DUTY BOWL OPEN FRONT SEAT LESS COVER WITH EVERCLEAN SURFACE INSTALL WITH WC-1
WC-2 EXISTING EXISTING EXISTING TOILET AND FLUSH VALVE
UR-1 AMERICAN STANDARD 6550.001 UNIVERSAL URINAL; VITREOUS CHINA, FLUSHING RIM, SIPHON JET FLUSH, 3
4" INLET AND 2" OUTLET CONNECTIONS PROVIDE WITH UR-1.1 AND UR-1.2
UR-1.1 SLOAN ROYAL 186-0.5 0.5 GPF POLISHED CHROME FLUSHOMETER. ADA COMPLIANT, TOP SPUD CONNECTION.INSTALL WITH UR-1
UR-1.2 ZURN Z1222 WALL URINAL SUPPORT SYSTEM WITH TOP SUPPORT PLATE AND LOWER BEARING PLATE.INSTALL WITH UR-1 AND UR-1.1
L-1 EXISTING EXISTING EXISTING LAVATORY AND LAVATORY FAUCET
L-1.1 ZURN Z1221 LAVATORY SUPPORT SYSTEM WITH TOP SUPPORT PLATE.INSTALL WITH RELOCATED LAVATORY
WATER HEATER SCHEDULE
TYPE MANUFACTURER MODEL DESCRIPTION DIMENSIONS, IN WEIGHT, LBS TYPE FUEL
MIN. FLOW TO
ACTIVATE TEMP. RISE ENERGY FACTORY VOLTAGE PHASE WATTS NOTES
WH-1 STIEBEL ELTRON 232099 INSTANTANEOUS WATER HEATER 7.5"(W) X 6.5"(H) X 3.25"(D)3.44 ELECTRIC 0.40 GPM 48 °F 0.99 120 V 1 3.5 KW N/A
LEGEND2020 IECC COMPLIANCE
CODE SECTION COMPLIANCE
C404.2 WATER-HEATING EQUIPMENT AND HOT WATER STORAGE TANKS MEET OR EXCEED THE
REQUIREMENTS OF TABLE C404.2
C404.4 PIPING INSULATION SHALL BE IN ACCORDANCE WITH TABLE C403.11.3
C404.5 HEATED WATER SUPPLY PIPING SHALL BE IN ACCORDANCE WITH SECTION C404.5.1 OR
C404.5.2
C404.6
HEATED WATER CIRCULATION SHALL BE IN ACCORDANCE WITH SECTION C404.6.1. HEAT
TRACE TEMPERATURE MAINTENANCE SYSTEMS SHALL BE IN ACCORDANCE WITH SECTION
C404.6.2. CONTROLS FOR HOT WATER STORAGE SHALL BE IN ACCORDANCE WITH SECTION
C404.6.3.
P-001
DEMOLITION
EXISTING
02/27/2025
17 31 32
10/24/2025
106
RESTROOM
104
RESTROOM
103
RESTROOM
102
CORRIDOR
105
CORRIDOR
3
STAIR
101
LOBBY
111
TOWN BOARD/COURTROOM
108
CORRIDOR
109
OFFICE
110
OFFICE
107
OFFICE
L-1
WC-2
WC-2
WC-2 WC-2
L-2
L-2
3
33
3
4
5
6
7
M02A
RESTROOM
M01
CORRIDOR
M03
TENATE SPACE 2
M02
TENANT SPACE 1
1
2
SHEET OF
SHEET NUMBER
SHEET TITLE
PROJECT NUMBER
PROJECT
NORTH
CONSULTANT
It is a violation of the New York State Education
Law, Article 145 Sec. 7209, for any person
unless he is acting under the direction of a
licensed professional Architect, Engineer or
Land Surveyor to alter an item in any way. If an
item bearing the seal of an Architect, Engineer
or Land Surveyor is altered, the altering
Architect, Engineer or Land Surveyor shall affix
to the item his seal and the notation "altered by"
followed by his signature and the date of such
alteration, and a specific description of the
alteration.
PROJECT
2/
2
6
/
2
0
2
5
1
:
4
9
:
0
1
P
M
/CH
R
I
S
B
A
C
A
Fax (315) 487 - 5947
Tel (315) 488 - 0377
215 Wyoming Street
info@bellandspina.com
www.bellandspina.com
Fax (585) 487 - 9532
Suite 200
Tel (585) 200 - 5038
1163 Pittsford-Victor Rd
DATEMARK DESCRIPTION
The Contractor shall verify all dimensions and
notify the Architect in writing of any
discrepancies.
All drawings and specifications are the
property of the Architect and shall be used
only on the job designated.
CHECKED
SCALE
DRAWN
DATE
AS NOTED
Syracuse, NY 13204 Pittsford, NY 14534
Suite 201
0 25
716-23-002
TO
W
N
O
F
I
T
H
A
C
A
2
N
D
F
L
.
M
E
Z
Z
A
N
I
N
E
&
C
O
U
R
T
O
F
F
I
C
E
R
E
N
O
V
A
T
I
O
N
TO
W
N
O
F
I
T
H
A
C
A
T
O
W
N
H
A
L
L
21
5
N
O
R
T
H
T
I
O
G
A
S
T
R
E
E
T
IT
H
A
C
A
,
N
Y
Cl
i
e
n
t
P
r
o
j
e
c
t
N
o
:
BID DOCUMENTS
110 SOUTH ALBANY STREET
ITHACA, NEW YORK 14850
PH: 607-277-1118
PLUMBING
DEMOLITION PLANS
GS YB
Scale: 1/4"=1'-0"
FIRST FLOOR DEMOLITION PLAN1
Scale: 1/4"=1'-0"
MEZZANINE FLOOR DEMOLITION PLAN2
PD-101
1.ALL DEMO WORK THAT IMPACTS THE USE OF THE WHOLE BUILDING SHALL BE CONDUCTED ON SATURDAYS AND SUNDAYS IN ORDER TO MAINTAIN PROPER USE CASE
OF THE BUILDING.
DEMOLITION KEYNOTES
NUMBER NOTE
1
DECOMMISSION DCW AND DHW PIPING. CAP AND DRAIN DCW AND DHW PIPING IN MEZZANINE BATHROOM. DISCONNECT AND CAP PIPING IN
BASEMENT. LEAVE DCW AND DHW PIPING IN WALL.
2
REMOVE EXISTING FLUSH TANK TOILET, LAVATORY, LAVATORY FAUCET, AND TRAP. CAP EXISTING SANITARY TO NEAREST FITTING FOR FUTURE
CONNECTIONS. IF VENT FROM MAIN STACK IS OBSTRUCTED DUE TO THE CAP PROVIDED TO SANITARY FITTINGS, TEMPORARY VENT PIPING SHALL BE
INSTALLED TO MAINTAIN STACK BETWEEN DEMO AND NEW CONSTRUCTION PHASES.
3
REMOVE AND RETAIN EXISTING FLUSH VALVE TOILETS. CLEAN FIXTURES FOR LATER REUSE. DEMOLISH SANITARY. DISCONNECT, CAP AND VALVE
DCW PIPING FOR FUTURE CONNECTIONS.
4 LAVATORY EXISTING TO REMAIN. KEEP EXISTING SANITARY RISER IN WALL AND VENT CONNECTION.
5
REMOVE AND RETAIN EXISTING LAVATORY, LAVATORY FAUCET AND P-TRAP. CLEAN FIXTURE FOR LATER REUSE. DISCONNECT AND CAP EXISTING
SANITARY AND VENT PIPING. ENSURE VENT PIPING CAN BE USED LATER FOR FUTURE CONNECTION. DICONNECT, CAP AND VALVE DCW AND DHW
PIPING FOR FUTURE CONNECTIONS.
6
REMOVE AND DISPOSE OF EXISTING FLUSH VALVE TOILET. DEMOLISH AND CAP EXISTING SANITARY AND VENT PIPING TO NEAREST FITTING.
DEMOLISH DCW PIPING ROUTED TO FIXTURE, CAP AND VALVE AT TERMINATION POINT.
7
REMOVE AND RETAIN EXISTING LAVATORY, LAVATORY FAUCET AND P-TRAP. CLEAN FIXTURE FOR LATER REUSE. DEMOLISH AND CAP EXISTING
SANITARY AND VENT PIPING TO NEAREST FITTING. DEMOLISH DCW AND DHW PIPING ROUTED TO FIXTURE, CAP AND VALVE AT TERMINATION POINT.
PLUMBING GENERAL NOTES
2.ONE PUBLIC RESTROOM SHALL REMAIN OPEN AND ACCESSIBLE FOR USE AT ALL TIMES.
02/27/2025
18 31 32
10/24/2025
105
CORRIDOR
3
STAIR
101
LOBBY
111
TOWN BOARD/COURTROOM
108
CORRIDOR
109
OFFICE
110
OFFICE
107
OFFICE
104
RESTROOM
103
RESTROOM
102
CORRIDOR
8
UR-1
7
6
6
WC-2
L-2
L-2
WC-2 WC-2
11
9
11
M03
TENANT SPACE 2
M02
TENANT SPACE 1
M01
CORRIDOR
M02A
RESTROOM
WC-1
L-1
1
3
2
WH-1
4
5
FC-1 FC-2
10 10
SHEET OF
SHEET NUMBER
SHEET TITLE
PROJECT NUMBER
PROJECT
NORTH
CONSULTANT
It is a violation of the New York State Education
Law, Article 145 Sec. 7209, for any person
unless he is acting under the direction of a
licensed professional Architect, Engineer or
Land Surveyor to alter an item in any way. If an
item bearing the seal of an Architect, Engineer
or Land Surveyor is altered, the altering
Architect, Engineer or Land Surveyor shall affix
to the item his seal and the notation "altered by"
followed by his signature and the date of such
alteration, and a specific description of the
alteration.
PROJECT
2/
2
6
/
2
0
2
5
1
:
4
9
:
0
5
P
M
/CH
R
I
S
B
A
C
A
Fax (315) 487 - 5947
Tel (315) 488 - 0377
215 Wyoming Street
info@bellandspina.com
www.bellandspina.com
Fax (585) 487 - 9532
Suite 200
Tel (585) 200 - 5038
1163 Pittsford-Victor Rd
DATEMARK DESCRIPTION
The Contractor shall verify all dimensions and
notify the Architect in writing of any
discrepancies.
All drawings and specifications are the
property of the Architect and shall be used
only on the job designated.
CHECKED
SCALE
DRAWN
DATE
AS NOTED
Syracuse, NY 13204 Pittsford, NY 14534
Suite 201
0 25
716-23-002
TO
W
N
O
F
I
T
H
A
C
A
2
N
D
F
L
.
M
E
Z
Z
A
N
I
N
E
&
C
O
U
R
T
O
F
F
I
C
E
R
E
N
O
V
A
T
I
O
N
TO
W
N
O
F
I
T
H
A
C
A
T
O
W
N
H
A
L
L
21
5
N
O
R
T
H
T
I
O
G
A
S
T
R
E
E
T
IT
H
A
C
A
,
N
Y
Cl
i
e
n
t
P
r
o
j
e
c
t
N
o
:
BID DOCUMENTS
110 SOUTH ALBANY STREET
ITHACA, NEW YORK 14850
PH: 607-277-1118
PLUMBING
FLOOR PLANS
GS YB
Scale: 1/4"=1'-0"
FIRST FLOOR PLAN1
Scale: 1/4"=1'-0"
MEZZANINE FLOOR PLAN2
P-101
1.ALL NEW WORK THAT IMPACTS THE USE OF THE WHOLE BUILDING SHALL BE CONDUCTED ON SATURDAYS AND SUNDAYS IN ORDER TO MAINTAIN PROPER
USE CASE OF THE BUILDING.
2.PLUMBING FIXTURES TO BE INSTALLED AND MOUNTED BY PLUMBING CONTRACTOR. GENERAL CONTRACTOR TO INSTALL ALL NECESSARY BLOCKING. GC
TO PERFORM ALL CORE DRILLING. COORDINATE LOCATIONS WITH GC.
3.ONE PUBLIC RESTROOM SHALL REMAIN OPEN AND ACCESSIBLE FOR USE AT ALL TIMES.
KEYNOTES
NUMBER NOTES
1
PROVIDE NEW CONDENSATE RECEPTOR IN RESTROOM FOR NEW MECHANICAL EQUIPMENT. PROVIDE NEW SANITARY PIPING FOR
CONDENSATE DRAIN. CONNECT NEW SANITARY PIPING INTO EXISTING SANITARY RISER. CONNECT CONDENSATE PIPING FROM FC-1 AND
FC-2 TO CONDENSATE DRAIN.
2 PROVIDE NEW FLUSH TANK TOILET (WC-1) AND CONNECT INTO NEW SANITARY AND DOMESTIC WATER CONNECTIONS.
3
REINSTALL LAVATORY L-1 RETAINED FROM DEMO, USING L-1.1 CARRIER MOUNT IN WALL. LAVATORY AND LAVATORY FAUCET SAVED FROM
OFFICE 109 BATHROOM. PROVIDE NEW P-TRAP AND KNEE GAURD FOR LAVATORY. CONNECT INTO EXISTING CAPPED SANITARY AND VENT
PIPING AND NEW DOMESTIC WATER CONNECTIONS.
4
PROVIDE A NEW INSTANTANEOUS WATER HEATER (WH-1) UNDERNEATH OR NEXT TO THE LAVATORY. SUPPLY THE LAVATORY WITH A 1/2"
DHW LINE FROM THE WATER HEATER.
5
PROVIDE NEW 3/4" DCW LINE IN FURRED OUT WALL, ROUGHLY 25' OF PIPE WILL BE REQUIRED. CONNECT NEW LINE INTO EXISTING DCW
DISTRIBUTION IN THE BASEMENT. USE NEW LINE TO SUPPLY TOILET, LAVATORY, AND WATER HEATER WITH 1/2" DCW CONNECTIONS.
6
REINSTALL LAVATORY, LAVATORY FAUCET AND P-TRAP RETAINED FROM DEMO, CONNECT INTO EXISTING SANITARY AND VENT PIPING.
PROVIDE NEW DOMESTIC WATER PIPING TO CONNECT INTO EXISTING DOMESTIC WATER DISTRIBUTION.
7 INSTALL UR-1 WITH UR-1.1 AND UR-1.2. UR-1.2 CARRIER IS INSTALLED IN WALL CAVITY AND MOUNTED TO FLOOR.
8 WET VENT WATER CLOSET AND URINAL THROUGH EXISTING LAVATORY VENT.
9 CONNECT NEW FIXTURES INTO EXISTING DOMESTIC WATER DISTRIBUTION THAT WAS CAPPED AND VALVED DURING DEMO. PROVIDE NEW
DOMESTIC WATER PIPING WHERE NECESSARY TO REACH NEW FIXTURE FROM THE CAPPED DOMESTIC WATER PIPE.
10
ROUTE 3
4" CONDENSATE PIPING FROM FC TO CONDENSATE RECEPTOR. PIPING SHALL BE ROUTED WITHIN FURRED OUT WALL. SLOPE
PIPING AT 1
8" / 12" TOWARDS THE DROP TO THE CONDENSATE RECEPTOR IN RESTROOM M02A.
11
REINSTALL FLUSH VALVE TOILET WC-2 RETAINED FROM DEMO, CONNECT INTO EXISTING DOMESTIC WATER DISTRIBUTION THAT WAS
CAPPED AND VALVED DURING DEMO. PROVIDE NEW DOMESTIC WATER PIPING WHERE NECESSARY TO REACH NEW FIXTURE FROM THE
CAPPED DOMESTIC WATER PIPE.
PLUMBING GENERAL NOTES
02/27/2025
19 31 32
10/24/2025
100 NODE NUMBER
SIDEWALL SPRINKLER
RECESSED PENDENT SPRINKLER
UPRIGHT SPRINKLER
LEGEND
CONNECT TO EXISTING
EXISTING (HALF TONE)
DEMOLITION
SHEET OF
SHEET NUMBER
SHEET TITLE
PROJECT NUMBER
PROJECT
NORTH
CONSULTANT
It is a violation of the New York State Education
Law, Article 145 Sec. 7209, for any person
unless he is acting under the direction of a
licensed professional Architect, Engineer or
Land Surveyor to alter an item in any way. If an
item bearing the seal of an Architect, Engineer
or Land Surveyor is altered, the altering
Architect, Engineer or Land Surveyor shall affix
to the item his seal and the notation "altered by"
followed by his signature and the date of such
alteration, and a specific description of the
alteration.
PROJECT
9/
2
5
/
2
0
2
5
2
:
0
8
:
2
3
P
M
/CH
R
I
S
B
A
C
A
Fax (315) 487 - 5947
Tel (315) 488 - 0377
215 Wyoming Street
info@bellandspina.com
www.bellandspina.com
Fax (585) 487 - 9532
Suite 200
Tel (585) 200 - 5038
1163 Pittsford-Victor Rd
DATEMARK DESCRIPTION
The Contractor shall verify all dimensions and
notify the Architect in writing of any
discrepancies.
All drawings and specifications are the
property of the Architect and shall be used
only on the job designated.
CHECKED
SCALE
DRAWN
DATE
AS NOTED
Syracuse, NY 13204 Pittsford, NY 14534
Suite 201
716-23-002
TO
W
N
O
F
I
T
H
A
C
A
2
N
D
F
L
.
M
E
Z
Z
A
N
I
N
E
&
C
O
U
R
T
O
F
F
I
C
E
R
E
N
O
V
A
T
I
O
N
TO
W
N
O
F
I
T
H
A
C
A
T
O
W
N
H
A
L
L
21
5
N
O
R
T
H
T
I
O
G
A
S
T
R
E
E
T
IT
H
A
C
A
,
N
Y
Cl
i
e
n
t
P
r
o
j
e
c
t
N
o
:
BID DOCUMENTS
110 SOUTH ALBANY STREET
ITHACA, NEW YORK 14850
PH: 607-277-1118
LEGEND AND NOTES
BAM YB
FP-001
The following are the documentation requirements for Fire Sprinkler Systems as required by the Fire Code of NYS and the Town of Ithaca.
Drawings to be provided to the Town of Ithaca Code Enforcement Department.
A.Working Plans shall be drawn to an indicated scale, on sheets of uniform size, with a plan of each floor, and shall show those items from the
following list that pertain to the design of the system:
1.Name of owner and occupant.
2.Location, including street address.
3.Point of compass.
4.Full height cross section, or schematic diagram, including structural member information if required for clarity and including ceiling
construction and method of protection for nonmetallic piping.
5.Location of partitions.
6.Location of fire walls.
7.Occupancy class of each area or room.
8.Location and size of concealed spaces, closets, attics, and bathrooms.
9.Any small enclosures in which no sprinklers are to be installed.
10.Size of city main in street and whether dead end or circulating; if dead end, direction and distance to nearest circulating main; and city
main test results and system elevation relative to test hydrant (see A.23.1.8).
11.Other sources of water supply, with pressure or elevation.
12.Make, type, model, and nominal K‐factor of sprinklers including sprinkler identification number.
13.Temperature rating and location of high temperature sprinklers.
14.Total area protected by each system on each floor.
15.Number of sprinklers on each riser per floor.
16.Total number of sprinklers on each dry pipe system, preaction system, combined dry pipe‐preaction system, or deluge system.
17.Approximate capacity in gallons of each dry pipe system.
18.Pipe type and schedule of wall thickness.
19.Nominal pipe size and cutting lengths of pipe (or center to center dimensions). Where typical branch lines prevail, it shall be necessary to
size only one typical line.
20.Location and size of riser nipples.
21.Type of fittings and joints and location of all welds and bends. The contractor shall specify on drawing any sections to be shop welded
and the type of fittings or formations to be used.
22.Type and locations of hangers, sleeves, braces, and methods of securing sprinklers when applicable.
23.All control valves, check valves, drain pipes, and test connections.
24.Make, type, model, and size of alarm or dry pipe valve.
25.Make, type, model, and size of preaction or deluge valve.
26.Kind and location of alarm bells.
27.Size and location of standpipe risers, hose outlets, hand hose, monitor nozzles, and related equipment.
28.Private fire service main sizes, lengths, locations, weights, materials, point of connection to city main; the sizes, types and locations of
valves, valve indicators, regulators, meters, and valve pits; and the depth that the top of the pipe is laid below grade.
29.Piping provisions for flushing.
30.Where the equipment is to be installed as an addition to an existing system, enough of the existing system indicated on the plans to make
all conditions clear.
31.For hydraulically designed systems, the information on the hydraulic data nameplate.
32.A graphic representation of the scale used on all plans.
33.Name and address of contractor.
34.Hydraulic reference points shown on the plan that correspond with comparable reference points on the hydraulic calculation sheets.
35.The minimum rate of water application (density or flow or discharge pressure), the design area of water application, in‐rack sprinkler
demand, and the water required for hose streams both inside and outside.
36.The total quantity of water and the pressure required noted at a common reference point for each system.
37.Relative elevations of sprinklers, junction points, and supply or reference points.
38.If room design method is used, all unprotected wall openings throughout the floor protected.
39.Calculation of loads for sizing and details of sway bracing.
40.The setting for pressure reducing valves.
41.Information about backflow preventers (manufacturer, size, type).
42.Information about antifreeze solution used (type and amount).
43.Size and location of hydrants, showing size and number of outlets and if outlets are to be equipped with independent gate valves.
Whether hose houses and equipment are to be provided, and by whom, shall be indicated. Static and residual hydrants that were used in
flow tests shall be shown.
44.Size, location, and piping arrangement of fire department connections.
45.Ceiling/roof heights and slopes not shown in the full height cross section.
46.Edition year of NFPA 13-2016 that the sprinkler system is designed to.
The Detailed worksheets or computer printout sheets shall contain the following information:
1.Sheet number
2.Sprinkler description and discharge constant (K)
3.Hydraulic reference points
4.Flow in gpm (L/min)
5.Pipe size
6.Pipe lengths, center to center of fittings
7.Equivalent pipe lengths for fittings and devices
8.Friction loss in psi/ft (bar/m) of pipe
9.Total friction loss between reference points
10.In-rack sprinkler demand balanced to ceiling demand
11.Elevation head in psi (bar) between reference points
12.Required pressure in psi (bar) at each reference point
13.Velocity pressure and normal pressure if included in calculations
14.Notes to indicate starting points or reference to other sheets or to clarify data shown
15.Diagram to accompany gridded system calculations to indicate flow quantities and directions for lines with sprinklers operating in the
remote area
16.Combined K-factor calculations for sprinklers on drops, armovers, or sprigs where calculations do not begin at the sprinkler
Sprinkler system components shall be listed and approved for the purpose for which they are installed.
All underground connections, above ground piping, and in building piping shall be inspected, hydrostatically tested, and flushed per
the requirements of NFPA 13-2016 and the Fire Code of New York State. Town of Ithaca shall perform all inspections. The Town of
Ithaca shall witness all flushing of piping, and testing of alarm devices. All hydrostatic testing shall be performed prior to any sprinkler
piping being concealed by walls, ceilings, or other obstructions from visual inspection. The Town of Ithaca, prior to the underground
service being concealed, shall witness hydrostatic testing and flushing of underground water services.
Upon completion of the installation, the contractor shall submit a written statement to the Town of Ithaca that the system has been
installed in accordance with approved plans and tested in accordance with the manufacturer's specifications, and the appropriate NYS
and NFPA 13-2016 requirements.
TOWN OF ITHACA DOCUMENTATION REQUIREMENTS SYSTEM TEST DATA
TEST DATE: 3/14/2024
STATIC: 85 PSI
RESIDUAL: 70 PSI
TEST STATUS: PASS
GENERAL
A.Provide a complete wet pipe fire sprinkler system per the latest edition of NFPA 13-2016, applicable codes, and the specifications.
B.Sprinkler design is performance based. Contractor shall design system subject to approval by AHJ, perform all hydraulic calculations, and submit stamped working drawings.
Drawings shall be stamped by Engineer Licensed in the State of New York.
C.Submit product data for valves, sprinklers, specialties, and alarms.
D.Occupancy is light hazard.
E.Concealed spaces above suspended ceilings are non-combustible per NFPA 13-2016 and do not require sprinklers.
F.Installation shall be made with piping run level plumb. And square to building structure in a neat manner. Changes in direction shall be made with proper pipe fittings.
G.The sprinkler layout, sizing, and routing are diagrammatic to represent the scope of work. Piping shown is illustrative of intended piping locations. Contractor shall field
determine all sprinkler locations, positions, pipe routing, sizing, and accessories to provide a fully sprinklered building.
H.Comply with NFPA 13-2016.
I.Use UL listed and labeled and FM approved pipe and fittings.
J.Comply with the fire code of New York State section 901.7 systems out of service. Notify fire department and code enforcement official.
K.Provide supervision of valves and flow switches.
L.Means shall be provided downstream of all backflow prevention valves for flow tests at system demand
M.The contractor shall arrange for all necessary hydrant flow tests and system inspections with the Town of Ithaca.
N.The contractor shall verify elevator shaft sprinkler requirements with elevator manufacturer and local code official.
CEILINGS
A.Ceiling type and heights are noted on the architectural drawings. Contractor shall verify ceiling and sprinkler installation details prior to final design of system.
B.Conceal sprinkler piping above suspended ceiling as indicated and wherever space permits. Center sprinklers in ceiling tiles as closely as possible. Minimum distance from
grid to sprinkler is 6".
C.Provide concealed sprinklers in all finished ceilings.
PIPING
A.The architect/engineer/owner shall be notified of conflicts in sprinkler system location prior to installation of conflicting elements.
B.Paint all exposed piping & fittings. Clean pipe surface free of excess oils, pipe joint compound, and debris to accept painting. Apply two coats of color selected by owner.
C.All trapped piping shall be fitted with a plugged outlet for draining. Provide drain valves wherever necessary to permit complete drainage of system.
D.Provide inspector test connections for testing and drainage purposes as required by NFPA 13-2016.
E.Provide hangers and seismic restraint per NFPA 13-2016 throughout.
F.All piping penetrations through masonry walls and floors shall be core drilled. Vacuum drilling bases shall be used to prevent damage to the walls.
G.Fire seal all pipe penetrations through fire rated partitions and floors at both ends with elastomer fire caulk.
H.Furnish and install split, chrome plated steel, floor and ceiling plates for all exposed pipe penetrations through walls and ceilings.
I.The contractor shall coordinate locations of standpipe and combined sprinkler/standpipe risers, valves and accessories locations with architect to maintain required stair
landing clearances.
STANDPIPES DURING CONSTRUCTION
A.In buildings required to have standpipes, not less than one standpipe shall be provided for use during construction. Such standpipes shall be installed prior to construction
exceeding 40 feet in height above the lowest level of fire department vehicle access.
B.Such standpipe shall be provided with fire department hose connections at accessible locations adjacent to usable stairways.
C.Such standpipes shall be extended as construction progresses to within one floor of the highest point of construction having secured decking or flooring.
FIRE PROTECTION SPECIFICATIONS
02/27/2025
10/24/2025
106
RESTROOM
104
RESTROOM
103
RESTROOM
102
CORRIDOR
105
CORRIDOR
3
STAIR
101
LOBBY
111
TOWN BOARD/COURTROOM
108
CORRIDOR
109
OFFICE
110
OFFICE
107
OFFICE
EXISTING SPRINKLER HEAD
M02A
RESTROOM
M01
CORRIDOR
M03
TENATE SPACE 2
M02
TENANT SPACE 1
2"
SPRINKLER HEAD
2
1
-
ATTIC SPACE
DN
1
1
1
1
1
1
SPRINKLER HEAD POSSIBLE
CONFLICT WITH MINIMUM
CLEARANCE FROM TOP OF
DEFLECTOR TO CEILING. VERIFY
COMPLIANCE AFTER INSULATION
WORK IS COMPLETE
SPRINKLER HEAD POSSIBLE
CONFLICT WITH MINIMUM
CLEARANCE FROM TOP OF
DEFLECTOR TO CEILING. VERIFY
COMPLIANCE AFTER INSULATION
WORK IS COMPLETE
DUCT WORK WITHIN DORMER
SPACE, NO SPRINKLER HEAD
MODIFICATION REQUIRED
SHEET OF
SHEET NUMBER
SHEET TITLE
PROJECT NUMBER
PROJECT
NORTH
CONSULTANT
It is a violation of the New York State Education
Law, Article 145 Sec. 7209, for any person
unless he is acting under the direction of a
licensed professional Architect, Engineer or
Land Surveyor to alter an item in any way. If an
item bearing the seal of an Architect, Engineer
or Land Surveyor is altered, the altering
Architect, Engineer or Land Surveyor shall affix
to the item his seal and the notation "altered by"
followed by his signature and the date of such
alteration, and a specific description of the
alteration.
PROJECT
9/
2
5
/
2
0
2
5
2
:
0
8
:
2
9
P
M
/CH
R
I
S
B
A
C
A
Fax (315) 487 - 5947
Tel (315) 488 - 0377
215 Wyoming Street
info@bellandspina.com
www.bellandspina.com
Fax (585) 487 - 9532
Suite 200
Tel (585) 200 - 5038
1163 Pittsford-Victor Rd
DATEMARK DESCRIPTION
The Contractor shall verify all dimensions and
notify the Architect in writing of any
discrepancies.
All drawings and specifications are the
property of the Architect and shall be used
only on the job designated.
CHECKED
SCALE
DRAWN
DATE
AS NOTED
Syracuse, NY 13204 Pittsford, NY 14534
Suite 201
716-23-002
TO
W
N
O
F
I
T
H
A
C
A
2
N
D
F
L
.
M
E
Z
Z
A
N
I
N
E
&
C
O
U
R
T
O
F
F
I
C
E
R
E
N
O
V
A
T
I
O
N
TO
W
N
O
F
I
T
H
A
C
A
T
O
W
N
H
A
L
L
21
5
N
O
R
T
H
T
I
O
G
A
S
T
R
E
E
T
IT
H
A
C
A
,
N
Y
Cl
i
e
n
t
P
r
o
j
e
c
t
N
o
:
BID DOCUMENTS
110 SOUTH ALBANY STREET
ITHACA, NEW YORK 14850
PH: 607-277-1118
SPRINKLER
DEMOLITION PLANS
BAM YB
Scale: 1/4"=1'-0"
FIRST FLOOR DEMOLITION PLAN1
Scale: 1/4"=1'-0"
MEZZANINE FLOOR DEMOLITION PLAN2
FPD-101
Scale: 3/16"=1'-0"
ATTIC DEMOLITION PLAN3
1.ATTIC SPRINKLER SYSTEM SUSPECTED TO BE SERVED BY DRY VALVE WITHIN BASEMENT AT SPRINKLER SERVICE.
2.PROTECT ALL ATTIC SPRINKLER HEADS PRIOR TO INSULATION WORK. COVER AS REQUIRED.
3.ALL SPACES ARE SPRINKLERED PER NFPA 13-2016 REQUIREMENTS. SPRINKLER HEADS OUTSIDE SCOPE OF WORK NOT SHOWN.
4.AFTER ATTIC INSULATION WORK IS COMPLETED CONTRACTOR SHALL VERIFY ALL SPRINKLER HEADS IN ATTIC ARE MAINTAINED WITH LISTED CLEARANCE
REQUIREMENTS. IF ANY SPRINKLER HEADS ARE FOUND OUT OF COMPLIANCE DEMOLISH HEAD PER KEY NOTE 1.DEMOLITION KEYNOTES
NUMBER NOTES
1 ISOLATE SPRINKLER MAIN SERVING SPACE. DRAIN PIPING, AND DEMOLISH SPRINKLER HEAD. CAP FOR FUTURE CONNECTION.
2 DEMOLISH PIPING, CAP OPEN ENDS FOR FUTURE CONNECTION.
FIRE PROTECTION GENERAL NOTES 1.ALL DEMO WORK THAT IMPACTS THE USE OF THE WHOLE BUILDING SHALL BE CONDUCTED ON SATURDAYS AND SUNDAYS IN ORDER TO MAINTAIN PROPER USE CASE
OF THE BUILDING.
DEMOLITION GENERAL NOTES
02/27/2025
10/24/2025
105
CORRIDOR
3
STAIR
101
LOBBY
111
TOWN BOARD/COURTROOM
108
CORRIDOR
109
OFFICE
110
OFFICE
107
OFFICE
104
RESTROOM
103
RESTROOM
102
CORRIDOR
4
M03
TENANT SPACE 2
M02
TENANT SPACE 1
M01
CORRIDOR
M02A
RESTROOM
2"
2
2
2
3
NEW HEAD 7.5' OFF OF NORTH WALL
2"
2"
FROM BUILDING SPRINKLER
SYSTEM
OFFSET PIPE SO PIPING PASSES THROUGH WALL
BETWEEN DOOR AND DIVIDING WALL, BETWEEN
RESTROOM AND TENANT SPACE 2
2"
NOTE: EXISTING SPRINKLERS IN
THIS AREA NOT SHOWN. SPRINKLER
PIPING SHOWN IN APPROXIMATE
LOCATIONS.
2"
5
-
ATTIC SPACE
DN
1
1
1
1
1
1
SHEET OF
SHEET NUMBER
SHEET TITLE
PROJECT NUMBER
PROJECT
NORTH
CONSULTANT
It is a violation of the New York State Education
Law, Article 145 Sec. 7209, for any person
unless he is acting under the direction of a
licensed professional Architect, Engineer or
Land Surveyor to alter an item in any way. If an
item bearing the seal of an Architect, Engineer
or Land Surveyor is altered, the altering
Architect, Engineer or Land Surveyor shall affix
to the item his seal and the notation "altered by"
followed by his signature and the date of such
alteration, and a specific description of the
alteration.
PROJECT
9/
2
5
/
2
0
2
5
2
:
0
8
:
3
3
P
M
/CH
R
I
S
B
A
C
A
Fax (315) 487 - 5947
Tel (315) 488 - 0377
215 Wyoming Street
info@bellandspina.com
www.bellandspina.com
Fax (585) 487 - 9532
Suite 200
Tel (585) 200 - 5038
1163 Pittsford-Victor Rd
DATEMARK DESCRIPTION
The Contractor shall verify all dimensions and
notify the Architect in writing of any
discrepancies.
All drawings and specifications are the
property of the Architect and shall be used
only on the job designated.
CHECKED
SCALE
DRAWN
DATE
AS NOTED
Syracuse, NY 13204 Pittsford, NY 14534
Suite 201
716-23-002
TO
W
N
O
F
I
T
H
A
C
A
2
N
D
F
L
.
M
E
Z
Z
A
N
I
N
E
&
C
O
U
R
T
O
F
F
I
C
E
R
E
N
O
V
A
T
I
O
N
TO
W
N
O
F
I
T
H
A
C
A
T
O
W
N
H
A
L
L
21
5
N
O
R
T
H
T
I
O
G
A
S
T
R
E
E
T
IT
H
A
C
A
,
N
Y
Cl
i
e
n
t
P
r
o
j
e
c
t
N
o
:
BID DOCUMENTS
110 SOUTH ALBANY STREET
ITHACA, NEW YORK 14850
PH: 607-277-1118
SPRINKLER
FLOOR PLANS
BAM YB
Scale: 1/4"=1'-0"
FIRST FLOOR PLAN1
Scale: 1/4"=1'-0"
MEZZANINE FLOOR PLAN2
FP-101
Scale: 3/16"=1'-0"
ATTIC PLAN3
1.IF ADDITIONAL SPRINKLER HEADS ARE FOUND TO BE OUT OF COMPLIANCE PROVIDE NEW HEAD PER KEY NOTE 1.
FIRE PROTECTION GENERAL NOTES KEYNOTES
NUMBER NOTES
1 PROVIDE NEW UPRIGHT SPRINKLER HEAD AT ELEVATION TO MAINTAIN LISTED CLEARANCE REQUIREMENTS TO CEILING STRUCTURE.
CONNECT TO EXISTING.
2 PROVIDE SIDE WALL SPRINKLER HEAD CONNECTING TO NEAREST PIPING BRANCH. PIPING SHALL BE MAINTAINED AT SAME ELEVATION AS
EXISTING BRANCH.
3 PROVIDE UPRIGHT SPRINKLER HEAD CONNECTING TO NEAREST PIPING BRANCH. PIPING SHALL BE MAINTAINED AT SAME ELEVATION AS
EXISTING BRANCH.
4 PROVIDE SEMI RECESSED PENDENT SPRINKLER HEAD CONNECTING TO NEAREST PIPING BRANCH. PIPING SHALL BE CONCEALED WITHIN
CEILING SPACE.
5 INSTALL NEW PIPING A MINIMUM OF 0'-3" AWAY FROM WALL.
02/27/2025
10/24/2025
LEGEND & NOTES
BAM YB
LEGEND
EXHAUST GRILLE
RETURN GRILLE
SUPPLY DIFFUSER
FLEX DUCT
VOLUME DAMPER
FIRE DAMPER
CONNECT TO EXISTING
ROOM SENSORS
CARBON DIOXIDE SENSORC
NITROGEN DIOXIDE SENSORN
OCCUPANCY SENSORO
THERMOSTATT
DEMOLISHED
EXISTING TO REMAIN
A.HEAT PUMP SYSTEMS:
1.1.During unoccupied periods as determined by 7 day programmable thermostat, the system shall be set back to adjustable
setpoint temperatures.
1.2.During occupied periods as determined by 7 day programmable thermostat, the system shall respond to setpoint temperatures.
Each fan coil shall have a thermostat for heating and cooling setpoints. The unit shall remain on until setpoint is reached.
B.ELECTRIC WALL HEATER
1.1.Wall heater shall have an internal digital thermostat (set to 68 degrees F) with lockout that is to control setpoint temperatures.
Upon a call for heat, the heater shall turn on and remain on. Upon setpoint being satisfied, the heater shall turn off and remain
off.
C.ENERGY RECOVERY VENTILATOR SYSTEMS:
1.1.ERV-1; Once enabled, the exhaust and outdoor air motorized dampers shall be open 100% and supply and exhaust fan shall run.
The unit shall be enabled by a wall mounted CO2 sensor located in each space and setpoint reading over 700 ppm (adjustable)
or a ceiling mounted occupancy sensor in each bathroom. Once the CO2 setpoint and occupancy sensors are satisfied the fan
shall stop and the exhaust and outdoor air motorized dampers shall be closed. The unit shall have an electric resistance duct
heater that the internal SRC controller shall control based on supply air temperature of 68 degrees F.
SEQUENCE OF OPERATIONS
2020 IECC COMPLIANCE
CODE SECTION COMPLIANCE
C105.2.1
REFERENCE MECHANICAL AND PLUMBING DOCUMENTS FOR DUCT AND PIPE INSULATION MATERIALS,
ARCHITECTURAL DOCUMENTS FOR ALL OTHER INSULATION MATERIALS
C105.2.2 REFERENCE ARCHITECTURAL PLANS FOR FENESTRATION U-FACTORS AND SOLAR HEAT GAIN COEFFICIENTS
C105.2.3 REFERENCE ARCHITECTURAL PLANS FOR AREA-WEIGHTED U-FACTORS AND SOLAR HEAT GAIN COEFFICIENTS
C105.2.4 MECHANICAL DESIGN CONFORMS TO 2020IECC AND IMC CODE REQUIREMENTS
C105.2.5 REFERENCE MECHANICAL AND PLUMBING DOCUMENTS FOR EQUIPMENT TYPES, SIZES AND EFFICIENCIES
C105.2.7 REFERENCE MECHANICAL DOCUMENTS FOR EQUIPMENT AND SYSTEM CONTROLS
C105.2.8 REFERENCE MECHANICAL DOCUMENTS FOR EQUIPMENT HORSEPOWER AND CONTROLS
C105.2.9 REFERENCE MECHANICAL AND PLUMBING SPECIFICATIONS FOR SEALING AND INSULATION LOCATIONS
C105.2.12 REFERENCE ARCHITECTURAL SPECIFICATIONS FOR AIR SEALING DETAILS
C403.3.1
HVAC LOAD SIZING HAS BEEN PERFORMED IN THE CARRIER HAP PROGRAM, USING RTS (HEAT BALANCE
METHODOLOGY
C403.3.2 ALL HVAC EQUIPMENT MEETS OR EXCEEDS MINIMUM EFFICIENCIES, REFERENCE MECHANICAL DOCUMENTS
C403.4 REQUIRED HVAC CONTROLS SHALL BE PROVIDED, REFERENCE MECHANICAL DOCUMENTS
C403.5.3 ECONOMIZER CONTROL NOT REQUIRED. ALL INDIVIDUAL UNIT COOLING CAPACITIES ARE LESS THAN 270,000
BTU/HR
C403.7.1 DEMAND CONTROL VENTILATION NOT REQUIRED PER EXCEPTION 3
C403.7.7 OUTDOOR AIR INTAKE AND EXHAUST OPENINGS AND STAIRWAY AND SHAFT VENTS SHALL BE PROVIDED WITH
CLASS I MOTORIZED DAMPERS
C403.11.1 DUCT IS REQUIRED TO BE INSULATED TO THE INDICATED MINIMUM LEVEL, REFERENCE MECHANICAL DOCUMENTS
C403.11.2 INSTALLING CONTRACTOR SHALL ENSURE THAT ALL AIR DISTRIBUTION COMPONENTS ARE PROPERLY SEALED
C403.11.3 ALL PIPING INSULATION CRITERIA HAS BEEN MET, REFERENCE MECHANICAL/PLUMBING DOCUMENTS
C408.1.1 OPERATION AND MAINTENANCE MANUAL SHALL BE PROVIDED TO OWNER BY CONTRACTOR FOR ALL EQUIPMENT
C408.2 MECHANICAL COMMISSIONING IS NOT REQUIRED
C408.2.2 INSTALLING CONTRACTOR SHALL TEST AND BALANCE ALL HVAC SYSTEMS AND PROVIDE REPORT TO ENGINEER
M-001
AIR TERMINAL SCHEDULE
TYPE MANUFACTURER MODEL DESCRIPTION COLOR AIR QUANTITY (CFM)ARRANGEMENT
NOISE CRITERIA
(MAX dB)NECK SIZE QUANTITY COMMENTS
A BROAN 641 EXHAUST NATURAL ALUMINUM 90 WALL NA 6"1 NA
B BROAN 641FA OUTDOOR AIR NATURAL ALUMINUM 90 WALL NA 6"1 NA
C TITUS 23R RETURN WHITE 40 CEILING 12 6X6 1 PROVIDE MOUNTING FRAME
D TITUS 23R RETURN WHITE 50 CEILING 12 6X6 1 PROVIDE MOUNTING FRAME
E TITUS 111RL SUPPLY WHITE 60 CEILING 11 6X6 1 PROVIDE MOUNTING FRAME
F TITUS 111RL SUPPLY WHITE 30 CEILING 11 6X6 1 PROVIDE MOUNTING FRAME
FAN COIL SCHEDULE
TYPE MANUFACTURER MODEL DESCRIPTION AIR FLOW CFM ESP, in. WC
COOLING
BTU/HR HEATING
LENGTH WIDTH HEIGHT WEIGHT, lbs
ELECTRICAL
COMMENTSTOTALBRU/HR VOLTAGE PHASE MCA
FC-1 LG LSN181HSV5 WALL MOUNTED FAN COIL 558 44 18,000 21,600 3'-3 9/32"0'-8 9/32"1'-1 19/32"25.6 208 1 0.4 PROVIDE ASPEN MINI AQUA CONDENSATE PUMP
FC-2 LG LSN090HSV5 WALL MOUNTED FAN COIL 268 36 9,000 10,900 2'-8 15/16"0'-7 7/16"1'-0 1/8"18.3 208 1 0.4 PROVIDE ASPEN MINI AQUA CONDENSATE PUMP
HEAT PUMP SCHEDULE
TYPE MANUFACTURER MODEL DESCRIPTION
COOLING HEATING
LENGTH WIDTH HEIGHT WEIGHT, LBS
ELECTRICAL
COMMENTSTOTAL BTU/HR CAPACITY BTU/HR VOLTAGE PHASE MCA
HP-1 LG LMU361HHV 3.0 TON HEAT PUMP 47,000 50,000 3'-1 13/32"1'-3 11/32"4'-6 11/32"218 208 1 32.7 PROVIDE QUICK SLING STAND, LG PMBD3620 BRANCH BOX (BB-1). FURNISH DISCONNECTS.
ENERGY RECOVERY VENTILATOR SCHEDULE
TYPE MANUFACTURER MODEL DESCRIPTION AIR FLOW CFM
SUPPLY ESP,
in. WC WEIGHT, LBS
DIMENSIONS ELECTRICAL
COMMENTSLENGTH (in)WIDTH (in)HEIGHT (in)VOLTAGE PHASE MCA
ERV-1 RENEWAIRE EV PREMIUM S INDOOR ENERGY RECOVERY VENTILATOR 130 0.10 32 30 22 15 120 1 15 PROVIDE 2 kW DUCT HEATER & MERV 8 FILTERS
ELECTRIC HEATER SCHEDULE
TYPE MANUFACTURER MODEL CFM KW LENGTH (in)WIDTH (in)HEIGHT (in)VOLTAGE PHASE
EH-1 QMARK SSHO4008 100 1.8-4.0 20 16 6 208 1
EH-2 STIEBEL ELTRON CNS 100-1 PLUS 1 18 17 4 120 1
PIPE INSULATION THICKNESS SCHEDULE
FLUID OPERATING
TEMPERATURE RANGE (°F)
INSULATION CONDUCTIVITY NOMINAL PIPE SIZE
CONDUCTIVITY
BRU*in/(hr*FT²*°F)
MEAN RATING
TEMPERATURE
(°F)
<1 1 TO
< 1 1/2
1 1/2 TO
< 4
4 TO
< 8 ≥8
105 - 140 0.21 - 0.28 100 1.0 1.0 1.5 1.5 1.5
NOTES:
1. FOR EXTERIOR PIPING, PROVIDE ADDITIONAL PROTECTIVE UV PIPE INSULATION. UV PAINT ON TOP OF PIPE INSULATION IS NOT ACCEPTABLE.
2. PROVIDE FACTORY APPLIED ASJ FOR ALL FIBERGLASS PIPE INSULATION.
3. PROVIDE VAPOR BARRIER ON ALL SYSTEMS OPERATING BELOW AMBIENT TEMPERATURE.
SHEET OF
SHEET NUMBER
SHEET TITLE
PROJECT NUMBER
PROJECT
NORTH
CONSULTANT
It is a violation of the New York State Education
Law, Article 145 Sec. 7209, for any person
unless he is acting under the direction of a
licensed professional Architect, Engineer or
Land Surveyor to alter an item in any way. If an
item bearing the seal of an Architect, Engineer
or Land Surveyor is altered, the altering
Architect, Engineer or Land Surveyor shall affix
to the item his seal and the notation "altered by"
followed by his signature and the date of such
alteration, and a specific description of the
alteration.
PROJECT
2/
2
6
/
2
0
2
5
1
:
5
2
:
2
1
P
M
/CH
R
I
S
B
A
C
A
Fax (315) 487 - 5947
Tel (315) 488 - 0377
215 Wyoming Street
info@bellandspina.com
www.bellandspina.com
Fax (585) 487 - 9532
Suite 200
Tel (585) 200 - 5038
1163 Pittsford-Victor Rd
DATEMARK DESCRIPTION
The Contractor shall verify all dimensions and
notify the Architect in writing of any
discrepancies.
All drawings and specifications are the
property of the Architect and shall be used
only on the job designated.
CHECKED
SCALE
DRAWN
DATE
AS NOTED
Syracuse, NY 13204 Pittsford, NY 14534
Suite 201
716-23-002
TO
W
N
O
F
I
T
H
A
C
A
2
N
D
F
L
.
M
E
Z
Z
A
N
I
N
E
&
C
O
U
R
T
O
F
F
I
C
E
R
E
N
O
V
A
T
I
O
N
TO
W
N
O
F
I
T
H
A
C
A
T
O
W
N
H
A
L
L
21
5
N
O
R
T
H
T
I
O
G
A
S
T
R
E
E
T
IT
H
A
C
A
,
N
Y
Cl
i
e
n
t
P
r
o
j
e
c
t
N
o
:
BID DOCUMENTS
110 SOUTH ALBANY STREET
ITHACA, NEW YORK 14850
PH: 607-277-1118
02/27/2025
23 31 32
10/24/2025
106
RESTROOM
104
RESTROOM
103
RESTROOM
102
CORRIDOR
105
CORRIDOR
3
STAIR
101
LOBBY
111
TOWN BOARD/COURTROOM
108
CORRIDOR
109
OFFICE
110
OFFICE
107
OFFICE
1
1
1
2
3 3 3
EXISTING PIPING
M02A
RESTROOM
M01
CORRIDOR
M03
TENATE SPACE 2
M02
TENANT SPACE 1
444
4
5
NOTE: REMOVE ABANDONED PIPES ON
THE NORTH AND EAST WALL. GC TO
PATCH AND FINISH. (TYP.)
EXISTING PIPING
DEMOLISH BRANCH BACK TO MAIN
DEMOLISH BRANCH BACK TO MAIN
DEMOLISH BRANCH BACK TO MAIN
MECHANICAL
DEMOLITION PLANS
BAM YB
Scale: 1/4"=1'-0"
FIRST FLOOR DEMOLITION PLAN2
Scale: 1/4"=1'-0"
MEZZANINE FLOOR DEMOLITION PLAN3
MD-101
Scale: 1/4"=1'-0"
BASEMENT DEMOLITION PLAN1
DEMOLITION KEYNOTES
NUMBER NOTES
1
DEMOLISH HYDRONIC RADIATORS IN BATHROOMS. DRAIN AND DEMOLISH BRANCH PIPING. RECONNECT PIPING INTO LOOP TO ENSURE HYDRONIC LOOP
IS OPERATIONAL AND HYDRONIC RADIATORS IN OFFICES 109 & 110 REMAIN OPERATIONAL. DEMOLISH THERMOSTATS, SOLENOID VALVES AND
DISCONNECT FROM CENTRAL BMS SYSTEM. REPROGRAM AS REQUIRED.
2 ERV EXHAUST IN SPACE TO REMAIN. REPROGRAM AS REQUIRED.
3 CLOSE ISOLATION VALVES IN BASEMENT BELOW FOR HYDRONIC RADIATORS (4 IN TOTAL) IN OFFICE 107, OFFICE 109, OFFICE 110 AND RESTROOM 106.
DRAIN AND DEMOLISH BRANCH PIPING. STORE RADIATORS AND BRANCH PIPING FOR REINSTALLATION. REPROGRAM AS REQUIRED.
4
DEMOLISH HYDRONIC RADIATORS IN TENANT SPACE 1 M02, RESTROOM M02A AND TENANT SPACE 2 M03. DRAIN AND DEMOLISH BRANCH PIPING.
RECONNECT REMAINING PIPING INTO LOOP TO ENSURE HYDRONIC LOOP IS OPERATIONAL. DEMOLISH THERMOSTATS, SOLENOID VALVES AND
DISCONNECT FROM CENTRAL BMS SYSTEM. REPROGRAM AS REQUIRED.
5 DEMOLISH THROUGH WALL EXHAUST FAN IN RESTROOM M02A.
MECHANICAL DEMOLITION NOTES
1.ALL DEMO WORK THAT IMPACTS THE USE OF THE WHOLE BUILDING SHALL BE CONDUCTED ON SATURDAYS AND SUNDAYS IN ORDER TO MAINTAIN PROPER USE CASE OF
THE BUILDING.
2.DEMOLISH ALL ABANDONED PIPING WITHIN FIRST FLOOR AND MEZZANINE SPACE. GC TO PATCH ALL WALL, FLOOR AND CEILING PENETRATIONS, COORDINATE ALL
LOCATIONS WITH GENERAL CONTRACTOR.
SHEET OF
SHEET NUMBER
SHEET TITLE
PROJECT NUMBER
PROJECT
NORTH
CONSULTANT
It is a violation of the New York State Education
Law, Article 145 Sec. 7209, for any person
unless he is acting under the direction of a
licensed professional Architect, Engineer or
Land Surveyor to alter an item in any way. If an
item bearing the seal of an Architect, Engineer
or Land Surveyor is altered, the altering
Architect, Engineer or Land Surveyor shall affix
to the item his seal and the notation "altered by"
followed by his signature and the date of such
alteration, and a specific description of the
alteration.
PROJECT
2/
2
6
/
2
0
2
5
1
:
5
2
:
3
8
P
M
/CH
R
I
S
B
A
C
A
Fax (315) 487 - 5947
Tel (315) 488 - 0377
215 Wyoming Street
info@bellandspina.com
www.bellandspina.com
Fax (585) 487 - 9532
Suite 200
Tel (585) 200 - 5038
1163 Pittsford-Victor Rd
DATEMARK DESCRIPTION
The Contractor shall verify all dimensions and
notify the Architect in writing of any
discrepancies.
All drawings and specifications are the
property of the Architect and shall be used
only on the job designated.
CHECKED
SCALE
DRAWN
DATE
AS NOTED
Syracuse, NY 13204 Pittsford, NY 14534
Suite 201
0 25
716-23-002
TO
W
N
O
F
I
T
H
A
C
A
2
N
D
F
L
.
M
E
Z
Z
A
N
I
N
E
&
C
O
U
R
T
O
F
F
I
C
E
R
E
N
O
V
A
T
I
O
N
TO
W
N
O
F
I
T
H
A
C
A
T
O
W
N
H
A
L
L
21
5
N
O
R
T
H
T
I
O
G
A
S
T
R
E
E
T
IT
H
A
C
A
,
N
Y
Cl
i
e
n
t
P
r
o
j
e
c
t
N
o
:
BID DOCUMENTS
110 SOUTH ALBANY STREET
ITHACA, NEW YORK 14850
PH: 607-277-1118
02/27/2025
24 31 32
10/24/2025
105
CORRIDOR
3
STAIR
101 111
108
CORRIDOR
109
OFFICE
110
OFFICE
107
OFFICE
104
RESTROOM
103
RESTROOM
102
CORRIDOR
2
1
1
22
EH-1
EH-1
EXISTING PIPING
M03
TENANT SPACE 2
M02
TENANT SPACE 1
M01
CORRIDOR
M02A
RESTROOM
3
33
4 5
FC-2FC-1
AIR TERMINAL "F" 30 CFMAIR TERMINAL "D" 50 CFM
AIR TERMINAL "C" 40 CFM
AIR TERMINAL "E" 60 CFM
EH-2
T T
C CO
EXISTING PIPING
-
ATTIC SPACE
DNERV-1
6" SUPPLY
4" SUPPLY
5" SUPPLY DOWN
TO TERMINAL "E"
6" RETURN
5" RETURN DOWN
TO TERMINAL "C"
5" RETURN
5" RETURN DOWN
TO TERMINAL "D"
4" SUPPLY DOWN
TO TERMINAL "F"
6" OA
6" SUPPLY
EXHAUST TERMINAL
"A" 90 CFM
6
OUTDOOR AIR TERMINAL "B"
90 CFM
6
BB-1 FOR HP-1/FC-1, FC-2
7
7
7
7
7
7
7
7
7
7
7
MECHANICAL
FLOOR PLANS
BAM YB
Scale: 1/4"=1'-0"
FIRST FLOOR PLAN1
Scale: 1/4"=1'-0"
MEZZANINE FLOOR PLAN2
Scale: 1/8"=1'-0"
ATTIC PLAN3
M-101
KEYNOTES
NUMBER NOTES
1 PROVIDE EH-1 BELOW WINDOW RECESSED INTO FURRED OUT WALL. GENERAL CONTRACTOR TO PROVIDE FURRED OUT WALL AND CUT
OUT FOR WALL HEATER.
2 LOCATE RADIATORS IN EXISTING LOCATIONS SHIFTED OUT AGAINST NEW FURRED OUT WALL. SUPPLY AND RETURN PIPING SHALL
EXTEND FROM BASEMENT THROUGH FURRED OUT WALL TO CONNECT TO RADIATORS.
3 2" DOOR UNDERCUT PROVIDED BY GENERAL CONTRACTOR.
4 PLACE FAN COIL OVER AND CENTERED BETWEEN WINDOWS. INSTALL FAN COIL TO MANUFACTURER'S SUPPLIED MOUNTING PANEL PER
MANUFACTURER'S INSTALLATION REQUIREMENTS.
5 PLACE FAN COIL OVER AND CENTERED ON WINDOW. INSTALL FAN COIL TO MANUFACTURER'S SUPPLIED MOUNTING PANEL PER
MANUFACTURER'S INSTALLATION REQUIREMENTS.
6 CENTER AIR TERMINAL IN WINDOW OPENING. INFILL WINDOW AROUND AIR TERMINAL TO MATCH EXISTING ERV AIR TERMINAL INFILL.
7
SUPPORT ERV FROM ROOF RAFTER ABOVE WITH 3/8" CORROSION RESISTANT STEEL THREADED ROD CONNECTED TO UNISTRUT
MOUNTED ON ROOF JOISTS. PROVIDE VIBRATION DAMPENING CONNECTIONS AT UNISTRUT AND EQUIPMENT CONNECTIONS. ALL
DUCTWORK SHALL BE HUNG FROM DUCT SUPPORTS FASTENED TO ROOF RAFTER.
NOT TO SCALE
ROOF PLAN4
MECHANICAL GENERAL NOTE:
1.CONNECT CONDENSATE INTO CONDENSATE MAIN PROVIDED BY PLUMBING CONTRACTOR.
2.REPROGRAM CENTRAL BMS SYSTEM AT ALL HYDRONIC LOOP LOCATIONS REMOVED FROM BUILDING AS REQUIRED. REFER TO KEYNOTES 1 AND 4 ON
MD-101.
3.SEAL ALL WALL, CEILING AND FLOOR PENETRATIONS. REFER TO ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR MORE INFORMATION. GENERAL
CONTRACTOR TO PATCH AND FINISH.
HP-1
SHEET OF
SHEET NUMBER
SHEET TITLE
PROJECT NUMBER
PROJECT
NORTH
CONSULTANT
It is a violation of the New York State Education
Law, Article 145 Sec. 7209, for any person
unless he is acting under the direction of a
licensed professional Architect, Engineer or
Land Surveyor to alter an item in any way. If an
item bearing the seal of an Architect, Engineer
or Land Surveyor is altered, the altering
Architect, Engineer or Land Surveyor shall affix
to the item his seal and the notation "altered by"
followed by his signature and the date of such
alteration, and a specific description of the
alteration.
PROJECT
2/
2
6
/
2
0
2
5
1
:
5
2
:
3
4
P
M
/CH
R
I
S
B
A
C
A
Fax (315) 487 - 5947
Tel (315) 488 - 0377
215 Wyoming Street
info@bellandspina.com
www.bellandspina.com
Fax (585) 487 - 9532
Suite 200
Tel (585) 200 - 5038
1163 Pittsford-Victor Rd
DATEMARK DESCRIPTION
The Contractor shall verify all dimensions and
notify the Architect in writing of any
discrepancies.
All drawings and specifications are the
property of the Architect and shall be used
only on the job designated.
CHECKED
SCALE
DRAWN
DATE
AS NOTED
Syracuse, NY 13204 Pittsford, NY 14534
Suite 201
0 5
716-23-002
TO
W
N
O
F
I
T
H
A
C
A
2
N
D
F
L
.
M
E
Z
Z
A
N
I
N
E
&
C
O
U
R
T
O
F
F
I
C
E
R
E
N
O
V
A
T
I
O
N
TO
W
N
O
F
I
T
H
A
C
A
T
O
W
N
H
A
L
L
21
5
N
O
R
T
H
T
I
O
G
A
S
T
R
E
E
T
IT
H
A
C
A
,
N
Y
Cl
i
e
n
t
P
r
o
j
e
c
t
N
o
:
BID DOCUMENTS
110 SOUTH ALBANY STREET
ITHACA, NEW YORK 14850
PH: 607-277-1118
NOTE: ROOF APPROXIMATELY
25'-0" AFG
02/27/2025
25 31 32
10/24/2025
HEAT PUMP
EQUIPMENT STAND
ROOF
FASTEN LEGS TO
SLEEPERS. DO NOT
PENETRATE ROOF
MEMBRANE.
2 LAYERS OF 1" (5/4) PLASTIC COMPOSITE
SLEEPERS, 40" LONG x 12" WIDE
SCHEMATICS & DETAILS
BAM YB
M-401
NOT TO SCALE
PIPING DIAGRAM1
NOT TO SCALE
HEAT PUMP STAND DETAIL2
LMU361HHV
Additional Refrigerant : 0.83 lbs (Precharged Refrigerant : 11.46 lbs)
(25.40 kBtu/h)(16.29/29.88 kBtu/h)
PMBD36203/8 : 3/4
50.0 ft
LSN181HSV5 #Mezzanine Large
(16.97/13.34 kBtu/h)(10.88/19.96 kBtu/h)
1/4 : 1/2
30.0 ft
LSN090HSV5 #Mezzanine Small
(8.43/6.63 kBtu/h)(5.41/9.92 kBtu/h)
1/4 : 3/8
30.0 ft
HP-1
SHEET OF
SHEET NUMBER
SHEET TITLE
PROJECT NUMBER
PROJECT
NORTH
CONSULTANT
It is a violation of the New York State Education
Law, Article 145 Sec. 7209, for any person
unless he is acting under the direction of a
licensed professional Architect, Engineer or
Land Surveyor to alter an item in any way. If an
item bearing the seal of an Architect, Engineer
or Land Surveyor is altered, the altering
Architect, Engineer or Land Surveyor shall affix
to the item his seal and the notation "altered by"
followed by his signature and the date of such
alteration, and a specific description of the
alteration.
PROJECT
2/
2
6
/
2
0
2
5
1
:
5
2
:
3
0
P
M
/CH
R
I
S
B
A
C
A
Fax (315) 487 - 5947
Tel (315) 488 - 0377
215 Wyoming Street
info@bellandspina.com
www.bellandspina.com
Fax (585) 487 - 9532
Suite 200
Tel (585) 200 - 5038
1163 Pittsford-Victor Rd
DATEMARK DESCRIPTION
The Contractor shall verify all dimensions and
notify the Architect in writing of any
discrepancies.
All drawings and specifications are the
property of the Architect and shall be used
only on the job designated.
CHECKED
SCALE
DRAWN
DATE
AS NOTED
Syracuse, NY 13204 Pittsford, NY 14534
Suite 201
0 25
716-23-002
TO
W
N
O
F
I
T
H
A
C
A
2
N
D
F
L
.
M
E
Z
Z
A
N
I
N
E
&
C
O
U
R
T
O
F
F
I
C
E
R
E
N
O
V
A
T
I
O
N
TO
W
N
O
F
I
T
H
A
C
A
T
O
W
N
H
A
L
L
21
5
N
O
R
T
H
T
I
O
G
A
S
T
R
E
E
T
IT
H
A
C
A
,
N
Y
Cl
i
e
n
t
P
r
o
j
e
c
t
N
o
:
BID DOCUMENTS
110 SOUTH ALBANY STREET
ITHACA, NEW YORK 14850
PH: 607-277-1118
02/27/2025
26 31 32
10/24/2025
LOWERCASE INDICATES SWITCHING
d
CIRCUIT BREAKER PANEL - REPLACE
NL D "NL" INDICATES NIGHT LIGHT
UPPERCASE INDICATES TYPE
LIGHT FIXTURE
CIRCUIT BREAKER PANEL - NEW
WALL MOUNTED FIXTURE
CEILING MOUNTED FIXTURE
DUPLEX RECEPTACLE
SWITCH
3-WAY3
OS
WALL MOUNTED EXIT LIGHT
OCCUPANCY SENSOR
JUNCTION BOX
WP
GROUND FAULT CIRCUIT INTERRUPTER
WEATHERPROOF
HOME RUN
GF
J
SAFETY SWITCH - UNFUSED
EMERGENCY FIXTURE
S
R
SMOKE DETECTOR
DUCT SMOKE DETECTOR
HEAT DETECTOR (ROR)
FIRE ALARM HORN/STROBE
D S
HD
SUPPLY DUCT
RETURN DUCT
CIRCUIT BREAKER PANEL - EXISTING
SAFETY SWITCH - FUSED
AC/BC ABOVE/BELOW COUNTER
D DIMMING
QUADRUPLEX RECEPTACLE
J
F
RJ45 DATA JACK
SWITCH - EXISTING
LEGEND
DEMOLISH
OS OCCUPANCY SENSOR
#
#NUMBER OF DATA JACKS
GENERAL NOTES:
1.ALL NEW WIRING, EXCEPT IN MECHANICAL AND UTILITY SPACES, SHALL BE CONCEALED UNLESS
NOTED OTHERWISE.
2.ALL COMMUNICATIONS WORK SHALL BE TESTED, CERTIFIED, AND DOCUMENTED. LABEL ALL WALL
PLATES AND COMMUNICATION ROOM TERMINATIONS WITH PERMANENT LABELS.
3.SUPPORT ALL WIRING BY THE BUILDING STRUCTURE USING DEVICES MANUFACTURED SPECIFICALLY
FOR THE INTENDED USE. ALL WIRING SHALL BE ARRANGED TO PERMIT REMOVAL OF CEILING TILES
AND ACCESS TO ALL EQUIPMENT.
4.PROVIDE DISCONNECTS FOR ALL EQUIPMENT AS REQUIRED BY NEC, UNLESS FURNISHED WITH
SPECIFIED EQUIPMENT. INSTALL DISCONNECTS WHEN FURNISHED WITH EQUIPMENT.
5.DEVICE HEIGHT ABOVE FINISH FLOOR TO CENTER (UNLESS OTHERWISE NOTED):
RECEPTACLE - 18"
WIREMOLD - 18"
VOICE/DATA - 18"
WALL TELEPHONE - 60"
SWITCH - 48"
EMERGENCY LIGHT - 84"
HORN/STROBE - 84"
PULL STATION - 48"
LEGENDS & NOTES
YB
LIGHTING FIXTURE SCHEDULE
PROVIDE AS SPECIFIED OR APPROVED EQUAL
MARK ITEM MANUF MODEL DESCRIPTION LAMP NOTES
A 2' X 2' SURFACE FIXTURE HE WILLIAMS LT-22-L39-835-AF/12W 2' X 2' SURFACE MOUNT DIRECT/INDIRECT DROP BASKED
FIXTURE, 3900 LUMENS, 80 CRI, 3500K LED
AE 2' X 2' SURFACE FIXTURE HE WILLIAMS LT-22-L39-835-AF-EM/12W 2' X 2' SURFACE MOUNT DIRECT/INDIRECT DROP BASKED
FIXTURE, 3900 LUMENS, 80 CRI, 3500K, WITH BATTERY BACKUP LED WITH BATTERY
BACKUP
B 6" X 2' SURFACE FIXTURE FINELITE HP-6-SM-D-835-F-96LG-120 6" X 1' SURFACE MOUNT, 5200 LUMENS, 80 CRI, 3500K LED
BE 6" X 2' SURFACE FIXTURE FINELITE HP-6-SM-D-835-F-96LG-120-LGD10W 6" X 1' SURFACE MOUNT, 5200 LUMENS, 80 CRI, 3500K LED WITH BATTERY
BACKUP
C 2' X 2' SURFACE FIXTURE HE WILLIAMS LT-22-L39-835-AF/12W 2' X 2' SURFACE SURFACE MOUNT DIRECT/INDIRECT DROP
BASKED FIXTURE, 3900 LUMENS, 80 CRI, 3500K LED LT-22-SMK-W
CE 2' X 2' SURFACE FIXTURE HE WILLIAMS LT-22-L39-835-AF-EM/12W 2' X 2' SURFACE MOUNT DIRECT/INDIRECT DROP BASKED
FIXTURE, 3900 LUMENS, 80 CRI, 3500K, WITH BATTERY BACKUP LED
LT-22-SMK-W;
WITH BATTERY
BACKUP
X1 EXIT SIGN THE EXIT LIGHT CO.LEDT-R-W-BB WALL MOUNTED EXIT SIGN LED WITH BATTERY
BACKUP
2020 IECC COMPLIANCE
CODE SECTION COMPLIANCE
C405.2 LIGHTING CONTROL CRITERIA HAVE BEEN MET, REFER TO LIGHTING SCHEDULE NOTES
C405.6 ELECTRICAL POWER HAS BEEN PROVIDED PER CODE
E-001
EQUIPMENT CONNECTION SCHEDULE
UNIT NO.LOCATION VOLTS / PHASE UNIT M.C.A.UNIT MOCP VA PANEL
HP-1 ROOF 208/1 32.7 50 6801 M-1,3
ERV-1 ATTIC 120/1 15 20 1800 M-9
BB-1 ATTIC 208/1 0.08 20 16 M-12,14
FC-1 MEZZANINE 208/1 0.4 20 8.5 M-15,17
FC-2 MEZZANINE 208/1 0.4 20 8.5 M-15,17
EH-1 1ST FLOOR 208/1 14.4 20 3000 Existing Panel A
EH-2 MEZZANINE 120/1 8.3 20 1000 M-11
WH-1 MEZZANINE 120/1 29 40 3500 M-16
DUCT HEATER ATTIC 120/1 16.7 25 2000 M-2
SHEET OF
SHEET NUMBER
SHEET TITLE
PROJECT NUMBER
PROJECT
NORTH
CONSULTANT
It is a violation of the New York State Education
Law, Article 145 Sec. 7209, for any person
unless he is acting under the direction of a
licensed professional Architect, Engineer or
Land Surveyor to alter an item in any way. If an
item bearing the seal of an Architect, Engineer
or Land Surveyor is altered, the altering
Architect, Engineer or Land Surveyor shall affix
to the item his seal and the notation "altered by"
followed by his signature and the date of such
alteration, and a specific description of the
alteration.
PROJECT
2/
2
6
/
2
0
2
5
1
:
3
5
:
4
6
P
M
/CH
R
I
S
B
A
C
A
Fax (315) 487 - 5947
Tel (315) 488 - 0377
215 Wyoming Street
info@bellandspina.com
www.bellandspina.com
Fax (585) 487 - 9532
Suite 200
Tel (585) 200 - 5038
1163 Pittsford-Victor Rd
DATEMARK DESCRIPTION
The Contractor shall verify all dimensions and
notify the Architect in writing of any
discrepancies.
All drawings and specifications are the
property of the Architect and shall be used
only on the job designated.
CHECKED
SCALE
DRAWN
DATE
AS NOTED
Syracuse, NY 13204 Pittsford, NY 14534
Suite 201
0 5
716-23-002
TO
W
N
O
F
I
T
H
A
C
A
2
N
D
F
L
.
M
E
Z
Z
A
N
I
N
E
&
C
O
U
R
T
O
F
F
I
C
E
R
E
N
O
V
A
T
I
O
N
TO
W
N
O
F
I
T
H
A
C
A
T
O
W
N
H
A
L
L
21
5
N
O
R
T
H
T
I
O
G
A
S
T
R
E
E
T
IT
H
A
C
A
,
N
Y
Cl
i
e
n
t
P
r
o
j
e
c
t
N
o
:
BID DOCUMENTS
110 SOUTH ALBANY STREET
ITHACA, NEW YORK 14850
PH: 607-277-1118
1.PROVIDE SUBMITTAL FOR EACH LIGHT FIXTURE FOR REVIEW BY OWNER AND ENGINEER.
2.FOR ANY SUBMITTED FIXTURE WITH SCREW-IN LAMPS, EC SHALL PROVIDE LED LAMPS AS APPROVED BY OWNER AND ENGINEER.
3.ALL LIGHTING IN COMMON AREAS TO BE 3000K, UNLESS OTHERWISE NOTED.
1.ALL OCCUPANCY/VACANCY SENSORS SHALL BE MANUALLY ADJUSTED TO EXTINGUISH LIGHTS AFTER A PERIOD OF 15 MINUTES OF INACTIVITY.
2.STAIRWELL LIGHT FIXTURES HAVE INTEGRATED MOTION SENSORS. REFER TO LIGHT FIXTURE SCHEDULE FOR CONTROL SETTINGS.
3.OCCUPANCY SENSORS SHALL CONTROL ALL HALL OR ROOM LIGHTING, UNLESS OTHERWISE NOTED. WHERE FIXTURES ARE TO REMAIN CONSTANTLY ILLUMINATED, UNOCCUPIED LIGHTING LEVELS SHALL BE 20% OF OCCUPIED LEVELS.
4.ALL EMERGENCY LIGHTING AND EXIT SIGNAGE SHALL HAVE INTEGRAL BATTERY BACKUP.
5.LIGHTS DESIGNATED WITH "E" ARE EMERGENCY FIXTURES, REFER TO LIGHTING SCHEDULE
6.CONTROL OF EXTERIOR LIGHTING, EGRESS AND SITE LIGHT FIXTURES SHALL HAVE DAYLIGHT SHUTOFF.
LIGHTING FIXTURE SCHEDULE NOTES
LIGHTING CONTROL NOTES
MLM
02/27/2025
27 3132
10/24/2025
106
RESTROOM
104
RESTROOM
103
RESTROOM
102
CORRIDOR
105
CORRIDOR
3
STAIR
101
LOBBY
111
TOWN BOARD/COURTROOM
108
CORRIDOR
109
OFFICE
110
OFFICE
107
OFFICE
OS
M02A
RESTROOM
M01
CORRIDOR
M03
TENATE SPACE 2
M02
TENANT SPACE 1
ELECTRICAL
DEMOLITION PLANS
MLM YB
Scale: 1/4"=1'-0"
FIRST FLOOR DEMOLITION PLAN1
Scale: 1/4"=1'-0"
MEZZANINE FLOOR DEMOLITION PLAN2
ED-101
1.ALL DEMO WORK THAT IMPACTS THE USE OF THE WHOLE BUILDING SHALL BE CONDUCTED ON SATURDAYS AND SUNDAYS IN ORDER TO MAINTAIN PROPER USE CASE
OF THE BUILDING.
2.REMOVE ALL ELECTRICAL LIGHTING AND POWER DEVICES BACK TO SOURCE. CIRCUIT BREAKERS TO BE LABELED AS SPARE WITHIN THE PANEL.
3.CONTRACTOR TO VERIFY THAT THE SURFACE MOUNTED RACEWAY TO THE ATTIC IS INDEED LIVE. IF IT IS LIVE, DISCONNECT DURING DEMOLITION AND RESTORE THE
CONNECTION TO THE ATTIC DURING CONSTRUCTION.
4.PROVIDE TEMPORARY POWER TO ABATEMENT CONTRACTOR.
ELECTRICAL DEMOLITION NOTES
SHEET OF
SHEET NUMBER
SHEET TITLE
PROJECT NUMBER
PROJECT
NORTH
CONSULTANT
It is a violation of the New York State Education
Law, Article 145 Sec. 7209, for any person
unless he is acting under the direction of a
licensed professional Architect, Engineer or
Land Surveyor to alter an item in any way. If an
item bearing the seal of an Architect, Engineer
or Land Surveyor is altered, the altering
Architect, Engineer or Land Surveyor shall affix
to the item his seal and the notation "altered by"
followed by his signature and the date of such
alteration, and a specific description of the
alteration.
PROJECT
2/
2
6
/
2
0
2
5
1
:
3
5
:
5
6
P
M
/CH
R
I
S
B
A
C
A
Fax (315) 487 - 5947
Tel (315) 488 - 0377
215 Wyoming Street
info@bellandspina.com
www.bellandspina.com
Fax (585) 487 - 9532
Suite 200
Tel (585) 200 - 5038
1163 Pittsford-Victor Rd
DATEMARK DESCRIPTION
The Contractor shall verify all dimensions and
notify the Architect in writing of any
discrepancies.
All drawings and specifications are the
property of the Architect and shall be used
only on the job designated.
CHECKED
SCALE
DRAWN
DATE
AS NOTED
Syracuse, NY 13204 Pittsford, NY 14534
Suite 201
0 25
716-23-002
TO
W
N
O
F
I
T
H
A
C
A
2
N
D
F
L
.
M
E
Z
Z
A
N
I
N
E
&
C
O
U
R
T
O
F
F
I
C
E
R
E
N
O
V
A
T
I
O
N
TO
W
N
O
F
I
T
H
A
C
A
T
O
W
N
H
A
L
L
21
5
N
O
R
T
H
T
I
O
G
A
S
T
R
E
E
T
IT
H
A
C
A
,
N
Y
Cl
i
e
n
t
P
r
o
j
e
c
t
N
o
:
BID DOCUMENTS
110 SOUTH ALBANY STREET
ITHACA, NEW YORK 14850
PH: 607-277-1118
02/27/2025
28 3132
10/24/2025
105
CORRIDOR
3
STAIR
101
LOBBY
111
TOWN BOARD/COURTROOM
108
CORRIDOR
109
OFFICE
110
OFFICE
107
OFFICE
104
RESTROOM
103
RESTROOM
102
CORRIDOR EXIST. PANEL 'A'
EH-1
EH-1
7
PANEL 'A'
34,36; 20A
BREAKER
PANEL 'A'
38,40; 20A
BREAKER
AC
GFI
7
7
8
J
J
J
8
J
11
J
10
J
4
4
J
8
12
12
14
48" AFF TO TOP OF DEVICE
48" AFF TO TOP OF DEVICE
48" AFF TO TOP OF DEVICE
2
2
2
2
14
14
M03
TENANT SPACE 2
M02
TENANT SPACE 1
M01
CORRIDOR
M02A
RESTROOM
AC
GFCI
(N) PANEL M
100A/3PH
120/208V
EH-2
FC-1
M-21
M-20
M-15,17
M-11
M-25 M-23
M-4
M-23
52
J
4
M-22 1
M-4
M-4
M-23
M-20 M-20
M-21
M-21
FC-2
M-15,17WH-1
M-16
9
9
J J J
3
13
2 2
2
2
22
2
ELECTRICAL
CLOSET
BOILER ROOM
HVAC
HVAC
SWBD
3
STUB UP NEW CONDUIT AND ROUTE
TOWARDS NEW LOCATION OF PANEL
'M' ON MEZZANINE FLOOR
IT ROOM IS TO THE
EAST OF HALLWAY
(NOT SHOWN)
OLD PHONE ROOM
ELECTICAL
FLOOR PLANS
YB
Scale: 1/4"=1'-0"
FIRST FLOOR PLAN1
Scale: 1/4"=1'-0"
MEZZANINE FLOOR PLAN2
MLM
E-101
KEYNOTES
NUMBER NOTES
1 POWER FOR DATA RACK
2 TERMINATE MEZZANINE CAT6A CABLES IN THIS ROOM.
3 SUPPLY 2-INCH CONDUIT EQUIPPED WITH (4) #3 WIRES TO CONNECT FROM THE SWITCHBOARD LOCATED IN THE BASEMENT ROUTING UP THROUGH ATTIC WALL AND THEN
DOWN TO NEW PANEL 'M' LOCATED ON THE MEZZANINE LEVEL. UTILIZE EXISTING 100A SPARE IN SWITCHBOARD.
4 PULL CAT6A WIRE FOR FUTURE CAMERA CONNECTION BACK TO BASEMENT IT ROOM. COIL UP ON BOTH ENDS FOR FUTURE CONNECTION. TERMINATE INTO BOX WITH RJ45
CONNECTION AND FACEPLATE. COORDINATE EXACT LOCATION WITH THE OWNER.
5 PROVIDE (1) 2" CONDUIT AND CAT6A FROM BASEMENT OLD PHONE ROOM TO DATA RACK LOCATED ON MEZZANINE LEVEL.
6 NOT USED
7 TIE NEW GENERAL POWER INTO EXISTING RECEPTACLES.
8 ELECTRICIAN TO INSTALL 18-4 STRANDED WIRE WITHIN DOOR FRAME TO STRIKE LOCATION. ELECTRICIAN TO INSTALL 22-6 STRANDED WIRE FROM CONTROL PANEL IN
BASEMENT IT ROOM TO JUNCTION BOX LOCATED ADJACENT TO DOOR FOR PROXIMITY SENSOR (PROXIMITY SENSOR BY OTHERS). COORDINATE WITH OWNER.
9 INSTALL NEW SURFACE RACEWAY AND ELECTRICAL BOXES.
10 PROVIDE POWER FOR DOOR OPERATOR. ELECTRICIAN TO INSTALL 22-6 STRANDED WIRE FROM OPERATOR TO CONTROL PANEL LOCATED IN BASEMENT IT ROOM.
11 JUNCTION BOX ON TOP OF COUNTER FOR ACCESS CONTROL. ELECTRICIAN TO INSTALL 18-4 STRANDED WIRE FROM JUNCTION BOX TO CONTROL PANEL IN BASEMENT IT ROOM.
DESIGN INTENT IS FOR ACCESS CONTROL TO UNLOCK DOOR 105-1. COORDINATE FINAL LOCATION WITH OWNER.
12
ADA ACTUATOR (BUTTON) FOR DOOR OPERATION, REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION AND MODEL NUMBER. ELECTRICIAN TO CONNECT ADA
ACTUATOR (BUTTON) TO DOOR OPERATOR. PUSH BUTTON LOCATED WITHIN OFFICE 107 TO BOTH UNLATCH ELECTRIC STRIKE AND OPEN DOOR. MOUNT PER MANUFACTURER'S
INSTRUCTIONS.
13 ELECTRICAL CONTRACTOR RESPONSIBLE FOR PROVIDING TEMPORARY POWER FOR ABATEMENT CONTRACTOR.
14 ALL FIRST FLOOR DATA TO TERMINATE IN BASEMENT IT ROOM.
Scale: 1/8"=1'-0"
BASEMENT PLAN3
SHEET OF
SHEET NUMBER
SHEET TITLE
PROJECT NUMBER
PROJECT
NORTH
CONSULTANT
It is a violation of the New York State Education
Law, Article 145 Sec. 7209, for any person
unless he is acting under the direction of a
licensed professional Architect, Engineer or
Land Surveyor to alter an item in any way. If an
item bearing the seal of an Architect, Engineer
or Land Surveyor is altered, the altering
Architect, Engineer or Land Surveyor shall affix
to the item his seal and the notation "altered by"
followed by his signature and the date of such
alteration, and a specific description of the
alteration.
PROJECT
2/
2
6
/
2
0
2
5
1
:
3
6
:
0
7
P
M
/CH
R
I
S
B
A
C
A
Fax (315) 487 - 5947
Tel (315) 488 - 0377
215 Wyoming Street
info@bellandspina.com
www.bellandspina.com
Fax (585) 487 - 9532
Suite 200
Tel (585) 200 - 5038
1163 Pittsford-Victor Rd
DATEMARK DESCRIPTION
The Contractor shall verify all dimensions and
notify the Architect in writing of any
discrepancies.
All drawings and specifications are the
property of the Architect and shall be used
only on the job designated.
CHECKED
SCALE
DRAWN
DATE
AS NOTED
Syracuse, NY 13204 Pittsford, NY 14534
Suite 201
0 25
716-23-002
TO
W
N
O
F
I
T
H
A
C
A
2
N
D
F
L
.
M
E
Z
Z
A
N
I
N
E
&
C
O
U
R
T
O
F
F
I
C
E
R
E
N
O
V
A
T
I
O
N
TO
W
N
O
F
I
T
H
A
C
A
T
O
W
N
H
A
L
L
21
5
N
O
R
T
H
T
I
O
G
A
S
T
R
E
E
T
IT
H
A
C
A
,
N
Y
Cl
i
e
n
t
P
r
o
j
e
c
t
N
o
:
BID DOCUMENTS
110 SOUTH ALBANY STREET
ITHACA, NEW YORK 14850
PH: 607-277-1118
02/27/2025
29 3132
10/24/2025
DN
ERV-1
BB-1
HP-1
M-6
M-9
M-12,14
M-1,3
M-6
M-6
ELECTICAL
FLOOR PLAN &
SCHEMATIC
YBMLM
E-102
Scale: 1/8"=1'-0"
ATTIC/ROOF PLAN1
(N)
PANEL M
100A/3PH
120/208V
SWITCHBOARD
EXISTING
BASEMENT
MEZZANINE
(4) #3 IN 2-INCH CONDUIT
APPROXIMATELY 100'-0"
EXISTING
NOT TO SCALE
PARTIAL ELECTRICAL SINGLE LINE DIAGRAM2
1ST FLOOR
SHEET OF
SHEET NUMBER
SHEET TITLE
PROJECT NUMBER
PROJECT
NORTH
CONSULTANT
It is a violation of the New York State Education
Law, Article 145 Sec. 7209, for any person
unless he is acting under the direction of a
licensed professional Architect, Engineer or
Land Surveyor to alter an item in any way. If an
item bearing the seal of an Architect, Engineer
or Land Surveyor is altered, the altering
Architect, Engineer or Land Surveyor shall affix
to the item his seal and the notation "altered by"
followed by his signature and the date of such
alteration, and a specific description of the
alteration.
PROJECT
2/
2
6
/
2
0
2
5
1
:
3
6
:
0
3
P
M
/CH
R
I
S
B
A
C
A
Fax (315) 487 - 5947
Tel (315) 488 - 0377
215 Wyoming Street
info@bellandspina.com
www.bellandspina.com
Fax (585) 487 - 9532
Suite 200
Tel (585) 200 - 5038
1163 Pittsford-Victor Rd
DATEMARK DESCRIPTION
The Contractor shall verify all dimensions and
notify the Architect in writing of any
discrepancies.
All drawings and specifications are the
property of the Architect and shall be used
only on the job designated.
CHECKED
SCALE
DRAWN
DATE
AS NOTED
Syracuse, NY 13204 Pittsford, NY 14534
Suite 201
0 5
716-23-002
TO
W
N
O
F
I
T
H
A
C
A
2
N
D
F
L
.
M
E
Z
Z
A
N
I
N
E
&
C
O
U
R
T
O
F
F
I
C
E
R
E
N
O
V
A
T
I
O
N
TO
W
N
O
F
I
T
H
A
C
A
T
O
W
N
H
A
L
L
21
5
N
O
R
T
H
T
I
O
G
A
S
T
R
E
E
T
IT
H
A
C
A
,
N
Y
Cl
i
e
n
t
P
r
o
j
e
c
t
N
o
:
BID DOCUMENTS
110 SOUTH ALBANY STREET
ITHACA, NEW YORK 14850
PH: 607-277-1118
IT CLOSET - TENANT SPACE 1TENANT SPACE 1 TENANT SPACE 2
ATTIC
02/27/2025
30 3132
10/24/2025
105
CORRIDOR
3
STAIR
101
LOBBY
111
TOWN BOARD/COURTROOM
108
CORRIDOR
109
OFFICE
110
OFFICE
107
OFFICE
104
RESTROOM
103
RESTROOM
102
CORRIDOR
AE
AE
AE
AE
AE
AE
AE
AE
A
A
A
A
A
A
A
AE
X1
X1
NOTE: ALL LIGHTING SHOWN ON THIS PLAN TO BE CIRCUITED TO EXISTING PANEL A.
M03
TENANT SPACE 2
M02
TENANT SPACE 1
M01
CORRIDOR
M02A
RESTROOM
CE C C
CC CE
CE
CE
C
C
B
BE
CE
X1X1
X1
NOTE: ALL LIGHTING SHOWN IN THIS PLAN TO BE CIRCUITED TO PANEL M.
Scale: 1/4"=1'-0"
FIRST FLOOR PLAN1
Scale: 1/4"=1'-0"
MEZZANINE FLOOR PLAN2
LIGHTING & FIRE
ALARM
FLOOR PLANS
YBMLM
E-111
1.LOCATION OF EXISTING HEAT DETECTORS IN THE ATTIC MAY INTERFERE WITH THE INSTALLATION OF THE ATTIC INSULATION. IF REQUIRED, CONTRACTOR SHALL
DISCONNECT AND RECONNECT HEAT DETECTORS.
FIRE ALARM NOTES
SHEET OF
SHEET NUMBER
SHEET TITLE
PROJECT NUMBER
PROJECT
NORTH
CONSULTANT
It is a violation of the New York State Education
Law, Article 145 Sec. 7209, for any person
unless he is acting under the direction of a
licensed professional Architect, Engineer or
Land Surveyor to alter an item in any way. If an
item bearing the seal of an Architect, Engineer
or Land Surveyor is altered, the altering
Architect, Engineer or Land Surveyor shall affix
to the item his seal and the notation "altered by"
followed by his signature and the date of such
alteration, and a specific description of the
alteration.
PROJECT
2/
2
6
/
2
0
2
5
1
:
3
5
:
5
2
P
M
/CH
R
I
S
B
A
C
A
Fax (315) 487 - 5947
Tel (315) 488 - 0377
215 Wyoming Street
info@bellandspina.com
www.bellandspina.com
Fax (585) 487 - 9532
Suite 200
Tel (585) 200 - 5038
1163 Pittsford-Victor Rd
DATEMARK DESCRIPTION
The Contractor shall verify all dimensions and
notify the Architect in writing of any
discrepancies.
All drawings and specifications are the
property of the Architect and shall be used
only on the job designated.
CHECKED
SCALE
DRAWN
DATE
AS NOTED
Syracuse, NY 13204 Pittsford, NY 14534
Suite 201
0 25
716-23-002
TO
W
N
O
F
I
T
H
A
C
A
2
N
D
F
L
.
M
E
Z
Z
A
N
I
N
E
&
C
O
U
R
T
O
F
F
I
C
E
R
E
N
O
V
A
T
I
O
N
TO
W
N
O
F
I
T
H
A
C
A
T
O
W
N
H
A
L
L
21
5
N
O
R
T
H
T
I
O
G
A
S
T
R
E
E
T
IT
H
A
C
A
,
N
Y
Cl
i
e
n
t
P
r
o
j
e
c
t
N
o
:
BID DOCUMENTS
110 SOUTH ALBANY STREET
ITHACA, NEW YORK 14850
PH: 607-277-1118
02/27/2025
31 31 32
10/24/2025
PANEL SCHEDULES
YBMLM
E-601
SHEET OF
SHEET NUMBER
SHEET TITLE
PROJECT NUMBER
PROJECT
NORTH
CONSULTANT
It is a violation of the New York State Education
Law, Article 145 Sec. 7209, for any person
unless he is acting under the direction of a
licensed professional Architect, Engineer or
Land Surveyor to alter an item in any way. If an
item bearing the seal of an Architect, Engineer
or Land Surveyor is altered, the altering
Architect, Engineer or Land Surveyor shall affix
to the item his seal and the notation "altered by"
followed by his signature and the date of such
alteration, and a specific description of the
alteration.
PROJECT
2/
2
6
/
2
0
2
5
1
:
3
5
:
5
9
P
M
/CH
R
I
S
B
A
C
A
Fax (315) 487 - 5947
Tel (315) 488 - 0377
215 Wyoming Street
info@bellandspina.com
www.bellandspina.com
Fax (585) 487 - 9532
Suite 200
Tel (585) 200 - 5038
1163 Pittsford-Victor Rd
DATEMARK DESCRIPTION
The Contractor shall verify all dimensions and
notify the Architect in writing of any
discrepancies.
All drawings and specifications are the
property of the Architect and shall be used
only on the job designated.
CHECKED
SCALE
DRAWN
DATE
AS NOTED
Syracuse, NY 13204 Pittsford, NY 14534
Suite 201
0 25
716-23-002
TO
W
N
O
F
I
T
H
A
C
A
2
N
D
F
L
.
M
E
Z
Z
A
N
I
N
E
&
C
O
U
R
T
O
F
F
I
C
E
R
E
N
O
V
A
T
I
O
N
TO
W
N
O
F
I
T
H
A
C
A
T
O
W
N
H
A
L
L
21
5
N
O
R
T
H
T
I
O
G
A
S
T
R
E
E
T
IT
H
A
C
A
,
N
Y
Cl
i
e
n
t
P
r
o
j
e
c
t
N
o
:
BID DOCUMENTS
110 SOUTH ALBANY STREET
ITHACA, NEW YORK 14850
PH: 607-277-1118
1. BOLD REPRESENTS NEW CIRCUIT BREAKER.
Notes:
Total Est. Demand Current:157 A
Total Conn. Current:157 A
Total Est. Demand:56675 VA
Total Conn. Load:56675 VA
Load Classification Connected Load Demand Factor Estimated Demand Panel Totals
Legend:
Total Amps:158 A 160 A 155 A
Total Load:18.93 KVA 19.13 KVA 18.63 KVA
41 EXISTING 20 A 1 1.2 1.2 1 20 A EXISTING 42
39 EXISTING 20 A 1 1.2 2.0 ------40
37 EXISTING 20 A 1 1.2 2.0 2 30 A (N) EH-1 38
35 EXISTING 20 A 1 1.2 2.0 ------36
33 EXISTING 20 A 1 1.2 2.0 2 30 A (N) EH-1 34
31 EXISTING 20 A 1 1.2 1.93 ------32
29 EXISTING 20 A 1 1.2 1.93 ------30
27 EXISTING 20 A 1 1.2 1.93 3 20 A EXISTING 28
25 EXISTING 20 A 1 1.2 1.2 1 20 A EXISTING 26
23 EXISTING 20 A 1 1.2 1.2 1 20 A EXISTING 24
21 EXISTING 20 A 1 1.2 1.2 1 20 A EXISTING 22
19 EXISTING 20 A 1 1.2 1.2 1 20 A EXISTING 20
17 EXISTING 20 A 1 1.2 1.2 1 20 A EXISTING 18
15 EXISTING 20 A 1 1.2 1.2 1 20 A EXISTING 16
13 EXISTING 20 A 1 1.2 1.2 1 20 A EXISTING 14
11 EXISTING 20 A 1 1.2 1.2 1 20 A EXISTING 12
9 EXISTING 20 A 1 1.2 1.2 1 20 A EXISTING 10
7 EXISTING 20 A 1 1.2 1.2 1 20 A EXISTING 8
5 EXISTING 20 A 1 1.2 1.2 1 20 A EXISTING 6
3 EXISTING 20 A 1 1.2 1.2 1 20 A EXISTING 4
1 EXISTING 20 A 1 1.2 1.2 1 20 A EXISTING 2
CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT
Notes:
Enclosure:NEMA 1
Mounting:Recessed Wires:4 Mains Rating:200 A
Supply From:Phases:3 Mains Type:MCB
Location:CORRIDOR 108 Volts:120/208 Wye A.I.C. Rating:22K
Branch Panel:A
Notes:
Total Est. Demand Current:65 A
Total Conn. Current:65 A
Total Est. Demand:23526 VA
Total Conn. Load:23526 VA
Load Classification Connected Load Demand Factor Estimated Demand Panel Totals
Legend:
Total Amps:68 A 112 A 27 A
Total Load:7.5 KVA 12.8 KVA 3.3 KVA
29 SPACE --1 ----1 --SPACE 30
27 SPACE --1 ----1 --SPACE 28
25 RESTROOM - MEZZ FLOOR 20 A 1 0.12 0 1 20 A SPARE 26
23 TENANT SPACE 2 RECs 20 A 1 0.9 0 1 20 A LIGHTING - TENANT SPACE 1 & 2 24
21 TENANT SPACE 1 RECs 20 A 1 1.2 1.6 1 20 A DATA RACK 22
19 SPARE 20 A 1 0 1.2 1 20 A TENANT SPACE 2 RECs 20
17 ------0.08 0 1 20 A SPARE 18
15 FC-1, FC-2 20 A 2 0.08 3.5 1 40 A WH-1 16
13 SPARE 20 A 1 0 0.8 ------14
11 EH-2 20 A 1 1.0 0.8 2 20 A BB-1 12
9 ERV-1 20 A 1 1.8 0 1 20 A SPARE 10
7 SPARE 20 A 1 0 0 1 20 A SPARE 8
5 SPARE 20 A 1 0 0.54 1 20 A 6
3 ------3.4 1.2 1 20 A TENANT SPACE 2 RECs 4
1 HP-1 50 A 2 3.4 2.0 1 25 A DUCT HEATER 2
CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT
Notes:
Enclosure:NEMA 1
Mounting:SURFACE Wires:4 Mains Rating:100 A
Supply From:Phases:3 Mains Type:MCB
Location:I.T.CLOSET - TENANT SPACE 1 Volts:120/208 Wye A.I.C. Rating:22K
Branch Panel:M
MLOSWITCHBOARD
ROOF GENERAL RECs
SWITCHBOARD
Other 8000 VA 100%8000 VA
Other 16766 VA 100%16766 VA
Receptacle 48675 VA 100%48675 VA
Receptacle 6760 VA 100%6760 VA
02/27/2025
31 3232
10/24/2025