HomeMy WebLinkAboutKingDanbyMicro_eSNAP_SA_20230201.pdf RecordID 27726 Date: February 1, 2023 LB V L AEN I N E E R I N G Christopher Miles Costich Engineering Albul Engineering, LLC 217 Lake Avenue 3840 E. Robinson Road Rochester, NY 14608 Amherst, NY 14228 (585)458-3020 (716)650-8147 cmiles@costich.com dalbul@albuleng.com Subject: Structural Opinion Letter Costich Engineering Job Number: 6130.01 Site Name: King Danby Micro Verizon Wireless Project Number: 20222362994 Location Code: 392588 Albul Engineering Project Number: 33401.COS.PEL.N36666.0 Site Data: 1100 Danby Road, Ithaca, NY, Tompkins County Latitude: 420 24' 27.46", Longitude: -76' 30' 13.74" Rooftop Equipment Installation Dear Mr. Miles, Albul Engineering has performed a structural assessment of the existing building located at the above-referenced address. The existing structure is a hotel. The property owner is Garuda Hotels, Inc. The assessment is based on the construction drawings by Costich Engineering, dated 01/16/2023, Radio Frequency Data Sheet by Verizon Wireless, dated 01/06/2023, and site photos, dated 12/05/2022 provided by the client. The original structural building drawings were not available to Albul Engineering at the time of this assessment. The final installation consists of one (1) non-penetration antenna frame installed on the building roof. The existing antenna frame will support one (1) Galtronics GQ2418-07488 panel antenna with 41.5-ft centerline above the ground level. The proposed one (1) Samsung B2/B66A RRH ORAN unit and one (1) Samsung CBRS RRH- RT4401-48A unit will be installed on the existing frame below the antenna. The antenna will be fed by twelve (12) coax cables from the equipment. The non-penetration antenna frame is held down in place with three hundred seventy-eight(378) pounds of ballast. Looking at this installation from a structural perspective, it is an engineering judgment of this office that the installation will have acceptable impact on the vertical and horizontal loads imposed on the building structure. The building is structurally sufficient to carry the proposed Verizon Wireless equipment. No conclusions, expressed or implied, shall indicate that Albul Engineering has made an evaluation of the original design, materials, fabrication, or potential erection deficiencies. In addition, the conclusions expressed herein are based upon the information contained within the aforementioned documents. Any information contrary to that assumed for the purpose of preparing this assessment could alter the findings and conclusions as stated. Respectfully submitted by: �pF NEW.44 yo �P� �P�Y V. Co 6 'Q G� t i w n u, 0890-7y 2 Dmitriy Albul, P.E. O�OFEWONP New York Engineering License Number: 089075 02-01-23 3840 E. Robinson Road, Amherst, NY 14228 716.800.1364 www.albuleng.com