Loading...
HomeMy WebLinkAboutOne Hard Copy & One Digital Copy of all Drawings and Specs RecordID 27726 verizon/ 1275 JOHN STREET,SUITE#100 WEST HENRIETTA,NEW YORK 14586 BELL ATLANTIC MOBILE SYSTEMS LLC CIVIL ENGINEERING d/b/a LAND SURVEYING •LANDSCAPE ARCHITECTURE COSTICH 217 Lnae Av- ROCRESTER,NY 14606 ENGINEERING (585)45t33020 ■ NO. DATE BY COMMENTS 0 01/16/2023 TKW ISSUED PREUMINARYFOR verizonREVIEW 1 02/02/2023 X ISSUED FINAL FOR PERMITTING SITE NAME : KING DANBY MICRO eSNAP CONSTRUCTION DRAWINGS PROJECT NUMBER: 20222362994 LOCATION CODE: 392588 �- PROJECT OFr°nuN�xF'"'"+ MANAGER _ �� DRAWN BY ZN a�Or= NrSinx�anM ��� VICINITY MAP PROJECT SUMMARY/DIRECTORY SHEET INDEX DIG SAFELY - NEW YORK ;�SSIO. T.K.W. SITE ADDRESS: 1100 DANBY ROAD SHEET DESCRIPTION REV REVISION e ,,6 ITHACA,NEW YORK 14850 # NO DATE Before You Dig,Drill Or Blast! COPYRIGHT 2023 ?' GCO01 TITLE SHEET 1 02/02/2023 COSTICH ENGINEERING,D.P.C. d MUNICIPALITY: TOWN OF ITHACA GC002 GENERAL NOTES 1 02/02/2023 DILATION OF o Dig iSafely. TIESS ACTING T EDIREC ONOF, OuDiG.Nys � UNLESS ACTING UNDER THE DIRECTION OF A COUNTY: COUNTY OF TOMPKINS CC100 OVERALL SITE PLAN 1 02/02/2023 New York LICENSED PROFESSIONAL ENGINEER,LAND SURVEYOR,ARCHITECT OR LANDSCAPE CC110 EXISTING AND PROPOSED SITE PLANS 1 02/02/2093 UNDERGROUND FACILITIES ARCHITECT,TO ALTER ANY ITEMONTHIS %% TAX MAP NUMBER: 37.1-1-9 2.71 ACRES PER TAX MAP CC200 EXISTING AND PROPOSED ELEVATIONS 1 02/02/2023 PROTECTIVE ORGANIZATION DOCUMENT IN ANY WAY.ANY LICENSEE WHO � ( ) CALL US TOLL FREE 1-800-962-7962 ALTERS THIS DOCUMENT IS REQUIRED BY LAW NY industrial code rule 753 requires no less than TO AFFIX HIS/HER SEAL AND THE NOTATION s _ LATITUDE: 42.407629°42°24'27.46"N re than ton ..ALTERED BY,FOLLOWED BY HIS/HER ( ) days notice . SIGNATURE AND SPECIFIC DESCRIPTION OF THE 4 LONGITUDE: -76.503817°(76°30'13.74"W) PER REF.#2 CC500 DETAILS 1 02/02/2023 two working days notice,but not mom RF INFORMATION 1 02/02/2023 ALTERATION,TO THE DOCUMENT. a.n•^°¢.,.°°° RF002 RADIO FREQUENCY EXPOSURE BARRIER AND SIGNAGE DETAILS 1 02/02/2023 SITE INFORMATION PROPERTY OWNER: GARUDA HOTELS,INC. 0 2303 N.TRIPHAMMER ROAD DO NOT SCALE DRAWINGS KING DANBY MICRO ITHACA,NEW YORK 14850 PROJECT#:20222362994 THESE DRAWINGS ARE FORMATTED FOR 22"x34"FULL SIZE AND 11"x17"HALF SIZE.OTHER LOCATION CODE:392588 SIZED VERSIONS ARE NOT PRINTED TO THE SCALE SHOWN.CONTRACTOR SHALL VERIFY ALL APPLICANT: BELL ATLANTIC MOBILE SYSTEMS,LLC PLANS,EXISTING DIMENSIONS&CONDITIONS ON THE JOB SITE&SHALL IMMEDIATELY NOTIFY E,"qq• d/b/a VERIZON WIRELESS THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK SITE • E KWG RD 1275 JOHN STREET,SUITE 100 OR BE RESPONSIBLE FOR SAME. TOWN OF ITHACA WEST HENRIETTA,NY 14586 COUNTY OF TOMPKINS ELECTRIC PROVIDER: NYSEG SCOPE OF WORK STATE OF NEW YORK o FIBER PROVIDER: VERIZON REMOVE(1)EXISTING RRH UNIT FROM EQUIPMENT RACK AT GROUND LEVEL. SHEET TITLE I � • - "" REMOVE(1)CANTENNA FROM EXISTING ROOFTOP ANTENNA SLED. • INSTALL(1)RRH UNIT,(1)CBRS RRH UNIT AND(1)CANTENNA ON EXISTING ROOFTOP TITLE SHEET u,o<. ANTENNA SLED. a INSTALL(10)COAX BETWEEN ROOFTOP AND GROUND EQUIPMENT. C.E.JOB NUMBER SHEET NUMBER ALL OTHER ROOFTOP AND GROUND EQUIPMENT TO REMAIN UNCHANGED. GCOO 1 v�N - 6130.01 SHEET 01 OF 07 LEGEND GENERAL NOTES I I SITE NOTES -- SECTION/PARCEL BOUNDARY 1. ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE 2018 INTERNATIONAL 1. ALL SITE WORK SHALL BE AS INDICATED ON THE DRAWINGS. MIN.BUILDING SETBACK BUILDING CODE(IBC),2020 BUILDING CODE OF NEW YORK STATE,THE NATIONAL ELECTRIC SAFETY CODE AND OTHER APPLICABLE LOCAL,STATE AND FEDERAL CODES.. 2. RUBBISH,STUMPS,DEBRIS,STICKS,STONES AND OTHER REFUSE SHALL BE REMOVED FROM ■ CENTER LINE THE SITE AND DISPOSED OF LEGALLY. verizo� -- EXIST.RIGHT-OF-WAY LINE 2. CONTRACTOR SHALL VISIT THE JOB SITE AND FAMILIARIZE HIMSELF WITH ALL CONDITIONS i/ EXISTING EASEMENT LINE. AFFECTING THE PROPOSED WORK AND MAKE PROVISIONS AS TO THE COST THEREOF. 3. THE SITE SHALL BE GRADED TO CAUSE SURFACE WATER TO FLOW AWAY FROM THE EXIST.CONCRETE CURB CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING HIMSELF WITH ALL CONTRACT PROPOSED PLATFORM. DOCUMENTS,FIELD CONDITIONS AND DIMENSIONS AND CONFIRMING THAT THE WORK MAY 1275 JOHN STREET,SUITE#100 EXIST.EDGE OF PAVEMENT BE ACCOMPLISHED AS SHOWN PRIOR TO PROCEEDING WITH CONSTRUCTION.ANY 4. NO FILL OR EMBANKMENT MATERIAL SHALL BE PLACED ON FROZEN GROUND.FROZEN WEST HENRIETTA,NEW YORK 14586 EXIST.EDGE OF GRAVEL DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO THE MATERIALS,SNOW OR ICE SHALL NOT BE PLACED IN ANY FILL OR EMBANKMENT. COMMENCEMENT OF WORK. w O s�yO w EXISTING WATER MAIN,VALVE,&HYDRANT. 5. THE SUBGRADE SHALL BE COMPACTED AND BROUGHT TO A SMOOTH UNIFORM GRADE PRIOR EXISTING SANITARY SEWER,&MANHOLE. 3. PLANS ARE NOT TO BE SCALED.THESE PLANS ARE INTENDED TO BE A DIAGRAMMATIC TO FINISHED SURFACE APPLICATION. OUTLINE ONLY,UNLESS OTHERWISE NOTED.THE WORK SHALL INCLUDE FURNISHING EXISTING DRAINAGE SEWER,FIELD INLET, MATERIALS,EQUIPMENT,APPURTENANCES,AND LABOR NECESSARY TO EFFECT ALL 6. ALL EXISTING ACTIVE SEWER,WATER,GAS,ELECTRIC,AND OTHER UTILITIES WHERE INLET MANHOLE,MANHOLE,&END SECTION. INSTALLATIONS AS INDICATED ON THE DRAWINGS. ENCOUNTERED IN THE WORK,SHALL BE PROTECTED AT ALL TIMES,AND WHERE REQUIRED ox ox EXISTING OVERHEAD UTILITIES FOR THE PROPER EXECUTION OF THE WORK,SHALL BE RELOCATED AS DIRECTED BY THE r r EXISTING TELEPHONE 4. DIMENSIONS SHOWN ARE TO FINISH SURFACES,UNLESS OTHERWISE NOTED.SPACING ENGINEER.EXTREME CAUTION SHOULD BE USED BY THE CONTRACTOR WHEN EXCAVATING BETWEEN EQUIPMENT IS REQUIRED CLEARANCE.THEREFORE,IT IS CRITICAL TO FIELD OR PIER DRILLING AROUND OR NEAR UTILITIES. •CIVIL uc uc EXISTING UNDERGROUND UTILITIES VERIFY DIMENSIONS.SHOULD THERE BE ANY QUESTIONS REGARDING THE CONTRACT ENGINEERING c c EXISTING GAS DOCUMENTS,EXISTING CONDITIONS AND/OR DESIGN INTENT,THE CONTRACTOR SHALL BE 7. ALL EXISTING INACTIVE SEWER,WATER,GAS,ELECTRIC AND OTHER UTILITIES,WHICH RESPONSIBLE FOR OBTAINING A CLARIFICATION FROM THE CARRIER'S AUTHORIZED INTERFERE WITH THE EXECUTION OF THE WORK,SHALL BE REMOVED AND/OR CAPPED, •LAND E E EXISTING ELECTRIC REPRESENTATIVE OR THE ENGINEER PRIOR TO PROCEEDING WITH THE WORK. PLUGGED OR OTHERWISE DISCONTINUED AT POINTS WHICH WILL NOT INTERFERE WITH THE SURVEYING w w EXISTING WATER LINE EXECUTION OF THE WORK,SUBJECT TO THE APPROVAL OF THE ENGINEER. 5. DETAILS ARE INTENDED TO SHOW END RESULT OF DESIGN.MINOR MODIFICATIONS MAY BE •LANDSCAPE ear Ear EXISTING ELEC&TELE REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS,AND SUCH MODIFICATIONS SHALL 8. THE AREAS OF THE OWNERS PROPERTY DISTURBED BY THE WORK SHALL BE GRADED TO A ARCHITECTURE EXISTING CABLE TV BE INCLUDED AS PART OF THE WORK. UNIFORM SLOPE,FERTILIZED,SEEDED,AND COVERED WITH MULCH. COSTICH 217 Lnxe AVExUE r r EXISTING FIBER ROCx[srex.rry lasos 5. CONTRACTOR SHALL RECEIVE CLARIFICATION IN WRITING,AND SHALL RECEIVE IN WRITING 9. CONTRACTOR SHALL MINIMIZE DISTURBANCE TO EXISTING SITE DURING CONSTRUCTION. ENGINEERING (585)45&3020 is is EXISTING LIGHT CONTROL AUTHORIZATION TO PROCEED BEFORE STARTING WORK ON ANY ITEMS NOT CLEARLY EROSION CONTROL MEASURES,IF REQUIRED DURING CONSTRUCTION,SHALL BE IN EXISTING GUARD RAIL DEFINED OR IDENTIFIED BY THE CONTRACT DOCUMENTS. CONFORMANCE WITH THE STATE GUIDELINES AND ANY LOCAL REGULATIONS. Qti N TREE,HEDGE,EDGE OF WOODS 7. CONTRACTOR SHALL NOTIFY THE CONSTRUCTION MANAGER OF ALL PRODUCTS OR ITEMS 10. ALL RESTORATION ISSUES SHALL BE COMPLETED WITHIN 72 HOURS OF THE COMPLETION OF NOTED AS"EXISTING"WHICH ARE NOT FOUND TO BE IN THE FIELD. THE WORK ACTIVITY OR WITHIN A REASONABLE AMOUNT OF TIME AS DIRECTED BY NO. DATE BY COMMENTS --�� EXISTING SWALE CONSTRUCTION MANAGERIENGINEER. BARBED WIRE,STOCKADE, 8. CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK USING THE BEST CONSTRUCTION 0 01/16/2023 TKW ISSUED PRELIMINARY FOR - X O D CHAIN LINKED FENCE SKILLS AND ATTENTION.CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR 11. CARE SHALL BE TAKEN TO RETAIN NATURAL GROWTH AND PREVENT DAMAGE TO TREES REVIEW ------410------------------- EXISTING CONTOUR CONSTRUCTION MEANS,METHODS,TECHNIQUES,SEQUENCES,PROCEDURES,AND FOR WITHIN AND OUTSIDE THE LIMITS OF CONSTRUCTION AND SPECIFIED WORKAREAS CAUSED 1 02/02/2023 JK ISSUED FINAL FOR COORDINATING ALL PORTIONS OF THE WORK UNDER CONTRACT,UNLESS OTHERWISE BY EQUIPMENT AND MATERIALS.ANY DAMAGE TO THIS NATURAL GROWTH SHALL BE PERMITTING x 420.4 EXISTING SPOT ELEVATION @ X NOTED. RESTORED AT THE EXPENSE OF THE CONTRACTOR. CONCRETE PAD/CONCRETE SIDEWALK 9. ERECTION SHALL BE DONE IN A WORKMANLIKE MANNER BY COMPETENT EXPERIENCED 12. ALL AREAS DISTURBED BY THE CONTRACTOR WITHOUT AUTHORIZATION SHALL BE RESTORED WORKMEN IN ACCORDANCE WITH APPLICABLE CODES AND THE BEST ACCEPTED BY THE CONTRACTOR. -- --- ---- PROPOSED EASEMENT LINE. PRACTICE.ALL MEMBERS SHALL BE LAID PLUMB AND TRUE AS INDICATED ON THE DRAWINGS. 13. IN THE EVENT THE CONTRACTOR DAMAGES AN EXISTING UTILITY SERVICE CAUSING AN PROPOSED CONCRETE CURB INTERRUPTION IN SAID SERVICE,HE SHALL IMMEDIATELY COMMENCE WORK TO RESTORE 10. CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY OF THE WORK AREA,ADJACENT SERVICE AND MAY NOT CONTINUE HIS WORK OPERATION UNTIL SERVICE IS RESTORED. 61) IN w PROPOSED WATER MAIN,VALVE,&HYDRANT AREAS,AND BUILDING OCCUPANTS THAT ARE LIKELY TO BE AFFECTED BY THE WORK -.�. .- PROPOSED SANITARY SEWER,&MANHOLE. UNDER THIS CONTRACT.WORK SHALL CONFORM TO ALL OSHA REQUIREMENTS. PROPOSED DRAINAGE SEWER,FIELD INLET, 11 CONTRACTOR SHALL COORDINATE HIS WORK AND SCHEDULE HIS ACTIVITIES AND ANTENNA MOUNTING NOTES INLET MANHOLE,MANHOLE,&END SECTION. WORKING HOURS IN ACCORDANCE WITH THE REQUIREMENTS OF THE OWNER. OH OH PROPOSED OVERHEAD UTILITIES 1. THE DESIGN AND CONSTRUCTION OF ANTENNA SUPPORTS SHALL CONFORM TO i i PROPOSED TELEPHONE 12. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING HIS WORK WITH THE WORK OF ANSI/TIA-222 H-2017"STRUCTURAL STANDARD FOR ANTENNA SUPPORTING STRUCTURES, OTHERS AS IT MAY RELATE TO RADIO EQUIPMENT,ANTENNAS AND ANY OTHER PORTIONS ANTENNAS AND SMALL WIND TURBINE SUPPORT STRUCTURES,"THE BUILDING CODE OF UG UG PROPOSED UNDERGROUND UTILITIES OF THE WORK. NEW YORK STATE,AND ALL OTHER APPLICABLE LOCAL,STATE,AND FEDERAL CODES. G G PROPOSED GAS SERVICE E E PROPOSED ELECTRIC SERVICE 13. CONTRACTOR SHALL MAINTAIN LIABILITY INSURANCE TO PROTECT THE OWNER AND 2. ALL STEEL MATERIALS SHALL GALVANIZED AFTER FABRICATION IN ACCORDANCE WITH CARRIER. ASTM A123"ZINC(HOT-DIP GALVANIZED)COATINGS ON IRON AND STEEL PRODUCTS", Eai Eai PROPOSED ELEC&TELE UNLESS OTHERWISE NOTED. SF SF PROPOSED SILT FENCE 14. INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY INDICATED OR WHERE LOCAL CODES OR 3. ALL BOLTS,ANCHORS AND MISCELLANEOUS HARDWARE SHALL BE GALVANIZED IN Os OS PROPOSED ORANGE CONSTRUCTION FENCE REGULATIONS TAKE PRECEDENCE. ACCORDANCE WITH ASTM A153"ZINC-COATING(HOT-DIP)ON IRON AND STEEL HARDWARE", SODLOD PROPOSED LIMITS OF DISTURBANCE UNLESS OTHERWISE NOTED. PROJECT 15. MAKE NECESSARY PROVISIONS TO PROTECT EXISTING SURFACES,EQUIPMENT, o""""" '"'•M MANAGER �FS�FS PROPOSED COMPOST FILTER SOCK IMPROVEMENTS,PIPING,ANTENNA AND ANTENNA CABLES.REPAIR ANY DAMAGE THAT 4. DAMAGED GALVANIZED SURFACES SHALL BE REPAIRED BY COLD GALVANIZING INS O °1 FI4, OCCURS DURING CONSTRUCTION. ACCORDANCE WITH ASTM A780"REPAIR OF DAMAGED AND UNCOATED AREAS OF HOT-DIP GALVANIZED COATINGS",USING COLD GALVANIZING COMPOUND AS MANUFACTURED BY 16. REPAIR ALL EXISTING SURFACES DAMAGED DURING CONSTRUCTION SUCH THAT THEY ZINGA-USA OR ZINC KOTE,OR ENGINEER APPROVED EQUAL WITH A MINIMUM METALLIC MATCH AND BLEND WITH ADJACENT SURFACES. ZINC CONTENT OF 95%BY WEIGHT IN DRY FILM.DRY FINISHED COATING THICKNESS SHALL BE 3 MILS MINIMUM. n a I 0 `�' DRAWN BY 17. KEEP CONTRACT AREA CLEAN,HAZARD FREE,AND DISPOSE OF ALL DEBRIS AND RUBBISH. `"y 2> EQUIPMENT NOT SPECIFIED AS REMAINING ON THE PROPERTY OF THE OWNER SHALL BE 5. ALL ANTENNA MOUNTS SHALL BE INSTALLED WITH DOUBLE NUTS AND SHALL BE INSTALLED m a2c�p< oss 54 REMOVED.LEAVE PREMISES IN CLEAN CONDITION AND FREE FROM PAINT SPOTS,DUST, IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. R""1 OR SMUDGES OF ANY NATURE.CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING mnnni"xww*� ALL ITEMS UNTIL COMPLETION OF CONSTRUCTION. 6. DESIGN OF THE ANTENNA MOUNTING BRACKETS,SUPPORTS,AND ALL COMPONENTS THEREOF AND ATTACHMENT THERETO SHALL BE THE RESPONSIBILITY OF THE 18. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD PRIOR TO MANUFACTURER.MANUFACTURER SHALL PROVIDE THE OWNER DRAWINGS DETAILING ALL COPYRIGHT 2023 FABRICATION AND ERECTION OF ANY MATERIAL.ANY UNUSUAL CONDITIONS SHALL BE COMPONENTS OF THE ASSEMBLY,INCLUDING CONNECTIONS,DESIGN LOADS,AND ALL COSTICH ENGINEERING,D.P.C. REPORTED TO THE ATTENTION OF THE ENGINEER. OTHER PERTINENT DATA.MANUFACTURER SHALL ALSO PROVIDE THE OWNER WITH A STATEMENT OF COMPLIANCE,INDICATING THAT THE ANTENNA SUPPORTS HAVE BEEN IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A 19. CONTRACTOR SHALL SECURE ALL NECESSARY BUILDING PERMITS AND INSPECTIONS AND DESIGNED IN ACCORDANCE WITH ANSIITIA-222-H-2017 STANDARDS.ALL SUBMISSIONS LICENSED PROFESSIONAL ENGINEER,LAND PAY ALL REQUIRED FEES. SHALL BEAR THE SIGNATURE AND SEAL OF A PROFESSIONAL ENGINEER LICENSED IN THE SURVEYOR,ARCHITECT OR LANDSCAPE STATE OF NEW YORK. ARCHITECT,TO ALTER AN V ITEM ON THIS 20. PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A OR DOCUMENT IN ANY WAY.ANY LICENSEE WHO ALTERS THIS DOCUMENT IS REQUIRED BY LAW 2-A/10-13C WITHIN 75 FEET TRAVEL DISTANCE TO ALL PORTIONS OF THE BUILDOUT AREA TO AFFIX HIS/HER SEAL AND THE NOTATION DURING CONSTRUCTION. p RE1-E pRE NC/'`E S SIGNATURE BY,FOLLOWED BY HIS/HER AND SPECIFIC DESCRIPTION OF THE 21. ALL BROCHURES,OPERATING AND MAINTENANCE MANUALS,CATALOGS,SHOP DRAWINGS ALTERATION,TO THE DOCUMENT, AND OTHER DOCUMENTATION SHALL BE TURNED OVER TO CARRIER AT COMPLETION OF 1. NO BOUNDARY SURVEY OR SEARCH OF DEEDS WAS PERFORMED.APPROXIMATE SITE INFORMATION CONSTRUCTION. PROPERTY LINES SHOWN HEREON PER MUNICIPAL/COUNTY TAX MAPS AND/OR KING DANBY MICRO AVAILABLE REFERENCE MAPPING. 22. COMPLETE JOB SHALL BE GUARANTEED FOR A PERIOD OF ONE(1)YEAR AFTER THE DATE PROJECT#:20222362994 OF ACCEPTANCE BY CARRIER.ANY WORK,MATERIALS,OR EQUIPMENT FOUND TO BE 2. ANTENNA COORDINATES ATTAINED THROUGH AUTOCAD CIVIL 3D GEOLOCATION DEFECTIVE DURING THAT PERIOD SHALL BE CORRECTED IMMEDIATELY UPON WRITTEN MAPPING BY BING MAPS ON THE NEW YORK STATE PLANES COORDINATE SYSTEM,NAD LOCATION CODE:392588 NOTIFICATION AT NO ADDITIONAL COST TO CARRIER. 83.BING MAPS SERVICES PROJECTED COORDINATE SYSTEM,MERCATOR AUXILIARY SPHERE ON THE GCS_WGS_1984 GEOGRAPHIC COORDINATE SYSTEM. 23. RIGGING OPERATIONS SHALL BE DONE IN ACCORDANCE WITH STATE AND FEDERAL TOWN OF ITHACA SAFETY REGULATIONS(OSHA).COSTICH ENGINEERING,CARRIER AND THE OWNER SHALL 3. PER DESIGN VISIT/SITE AUDIT INSPECTION PERFORMED COSTICH ENGINEERING D.P.C. BE HELD HARMLESS IN THE EVENT THE CONTRACTOR DOES NOT FOLLOW SUCH SAFETY ON 12/05/2023. COUNTY OF TOMPKINS REGULATIONS. 4. PER CONSTRUCTION DRAWINGS PREPARED BY COSTICH ENGINEERING D.P.C,SITE STATE OF NEW YORK 24. CONTRACTOR SHALL PROVIDE ACCESS TO THE SITE AND ASSIST THE RADIO EQUIPMENT NAME:KING DANBY,C.E.JOB NUMBER:6130,DATED 10/15/2015 LAST REVISED 0912312016. SHEET TITLE VENDOR AND THE ANTENNA INSTALLATION CONTRACTOR AS THEY MAY REQUIRE. 5. ANTENNAS SHALL BE INSTALLED IN ACCORDANCE WITH SITE SPECIFIC RF ANTENNA 25. CONTRACTORS MUST UTILIZE VERIZON WIRELESS APPROVED LOW-PIM CABLE SUPPORT DESIGN SHEET SUPPLIED BY VERIZON WIRELESS: FASTENERS AND RELATED ANCILLARY ATTACHMENT HARDWARE WITHIN 10 FEET OF FUZE PROJECT ID:16901356,DATED 0110 6/2 0 2 3. GENERAL NOTES VERIZON WIRELESS ANTENNAS. C.E.JOB NUMBER SHEET NUMBER 6130.01 GC002 SHEET 02 OF 07 / N W G� verizowl 0 z SUITE WEST HENR ETTA,NEW YORK 14586 EXISTING BELL ATLANTIC --�-- _ MOBILE SYSTEMS LLC EXTERIOR GROUND EQUIPMENT LEASE AREA=6'-0"x 8'-0" 48 f Sq.Ft. 04 CIVIL i ENGINEERING LAND EXISTING NON-PENETRATING r-- ----------- 9 I SURVEYING ANTENNA SLED _! - LANDSCAPE LAT:42.407629°(42°24'27.46"N) ( ARCHITECTURE LONG:-76.503817°(76°30'13.74"W) COSTICH 217Lnxe AVENUE ROCRESTE".NY 14608 y m ENGINEERING 585)45&3020 X Z� EXISTING BELL ATLANTIC MOBILE SYSTEMS LLC ROOFTOP ANTENNA LEASE AREA=4'-6"X 8'-0",36 t SQ.FT. - 0 NO. DATE BY COMMENTS 0 01/16/2023 TKW ISSUED PRELIMINARY FOR REVIEW 1 02/02/2023 JK ISSUED FINAL FOR _ PERMITTING O i ASSUMED LOCATION OF EXISTING INTERIOR ELECTRIC I �i n SERVICE AND FIBER ROUTING I --�— Z KING'S WAY 1 , I I -- -- -- EXISTING 2 STORY HOTEL `( PROJECT IpFnnN��M MANAGER a= G3 o `2> _ DRAWN BY ZN a^-�(-pa oFEss T.K.W. \\ I ' Ess IONP I mmm�xxxxm`"`"� COPYRIGHT 2023 COSTICH ENGINEERING,D.P.C. IIT IS A VIOLATION OF LAW FOR ANY PERSON, I I UNLESS ACTING UNDER THE DIRECTION OF LICENSED PROFESSIONAL ENGINEER,LAND SURVEYOR,ARCHITECT OR LANDSCAPE ARCHITECT,TO ALTER AN V ITEM ON THIS DOCUMENT IN ANY WAY.ANY LICENSEE WHO ALTERS THIS DOCUMENT IS REQUIRED BY LAW TO AFFIX HIS/HER SEAL AND THE NOTATION I "ALTERED BY,FOLLOWED BY HIS/HER SIGNATURE AND SPECIFIC DESCRIPTION OF THE - II ALTERATION,TO THE DOCUMENT. SITE INFORMATION KING DANBY MICRO PROJECT#:20222362994 LOCATION CODE:392588 / � I I TOWN OF ITHACA \\ �� COUNTY OF TOMPKINS \ I STATE OF NEW YORK SHEET TITLE GRAPHIC SCALE OVERALL SITE PLAN 30 0 15 30 60 120 OVERALL SITE PLAN C.E.JOB NUMBER SHEET NUMBER CC100 SCALE:1:=30(22 x 34 SHEET) (IN FEET) 613 0.01 CC 100 1"=60'(11 x 17 SHEET) 1 inch= 30 ft.(22"x 34"SHEET) 1 inch= 60 ft.(11"x 17"SHEET) SHEET 03 OF 07 N N z z Verizo %l 1275 JOHN STREET,SUITE#100 -'-----...- WEST HENRIETTA,NEW YORK 14586 EXISTING AC PANEL EXISTING BELL ATLANTIC EXISTING AC PANEL EXISTING BELL ATLANTIC •CIVIL MOBILE SYSTEMS LLC EXTERIOR MOBILE SYSTEMS LLC EXTERIOR ENGINEERING EXISTING GENERATOR RECEPTACLE GROUND EQUIPMENT LEASE EXISTING GENERATOR RECEPTACLE GROUND EQUIPMENT LEASE LAND EXISTING RECEPTACLE AREA=6'-0"x 8'-0",48 t Sq.Ft. EXISTING RECEPTACLE AREA=6'-0"x 8'-0",48 f Sq.Ft. SURVEYING EXISTING WOODEN FENCE EXISTING WOODEN FENCE LANDSCAPE ARCHITECTURE EXISTING STEPS EXISTING STEPS COSTICH 217 KEAVE"uE ROC"ESTE".NY 14606 ENGINEERING (585)45&3020 EXISTING GATE EXISTING LIGHT W/TIMER EXISTING BUILDING OVERHANG EXISTING GATE EXISTING LIGHT W/TIMER EXISTING BUILDING OVERHANG SWITCH BELOW SWITCH BELOW NO. DATE BY COMMENTS EXISTING FIBER ENCLOSURE EXISTING FIBER ENCLOSURE ISSUED PREUMINARYFOR 0 01/16/2023 TKW REVIEW _________-__-_------------------- - -�_ __ - 1 1 02/02/2023 JK ISSUED FINAL FOR I � ___- -_-______-_______-________-_______-_______-___- PERMITTING _- T11, EXISTING EXISTING RRH UNIT EXISTINGEQUIPMENT I TO BE REMOVED EQUIPMENT 1 CABINET CABINET II I En, En. 8T n, En. Enr s. 1II I � it i I I EXISTING CABLE ROUTING % EXISTING CABLE ROUTING ---------- 1 (2)ANTENNA COAX CABLES (2)ANTENNA COAX CABLES �- ------ -- (1)GPS COAX CABLE EXISTING CANTENNA (NH360QM-DG-2XR) --------_-"_-- _- _ (1)GPS COAX CABLE I PROPOSED CBRS RRH UNIT ~' ANTENNA CENTERLINE=41.5'±AGL I (RT4401-48A), �I TO BE REMOVED PROPOSED ROOFTOP CABLE ROUTING, CONTRACTOR TO UTILIZE EXISTING MOUNTED TO ANTENNA MOUNTING IF POSSIBLE,IF NOT UTILIZE SLED MAST PIPE PROJECT EXISTING NON-PENETRATING SHINGLEMOUNTSBYQUICKMOUNTPV EXISTING NON-PENETRATING •I, � wagwM MANAGER ANTENNA SLED _ _�- — — (10)ANTENNA COAX CABLES ANTENNA SLED LAT:42.407629°(42'24'27.46"N) LAT:42.407629"(42'24'27.46"N) LONG:-76.503817°(76°30'13.74"W) I LONG:-76.503817°(76'30'13.74"W) I atr_F `ir 1 PROPOSED CANTENNA DRAWN BY A CENT CS:GQ2418-0748 ossle4 e — I ANTENNA CENTERLINE=41.5't AGL — I R J s,°FEs °N w mmmxxxwn`"`" EXISTING BELL ATLANTIC MOBILE EXISTING BELL ATLANTIC MOBILE COPYRIGHT 2023 SYSTEMS LLC ROOFTOP ANTENNA LEASE SYSTEMS LLC ROOFTOP ANTENNA LEASE COSTICH ENGINEERING,D.P.C. AREA=4'-6"X 8'-0",36 f SQ.FT. AREA=4'-6"X 8'-10",36 f SQ.FT. IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER,LAND SURVEYOR,ARCHITECT OR LANDSCAPE EXISTING GPS ANTENNA ATTACHED EXISTING GPS ANTENNA ATTACHED ARCHITECT,TOALTERANYITEM DOCUMENT IN ANY WAY.ANY LICENSS THISEE WHO TO EXISTING ANTENNA SLED MAST NOTE., TO EXISTING ANTENNA SLED MAST ALTERS THIS DOCUMENT IS REQUIRED BY LAW EXISTING RF SIGNAGE AND BARRIERS SUBJECT TO AFFIX HIS/HER SEAL AND THE NOTATION PROPOSED RRH UNIT "ALTERED BY,FOLLOWED BY HIS/HER TO CHANGE PENDING NEW RFE REPORT,WHICH SIGNATURE AND SPECIFIC DESCRIPTION OF THE SHALL BE COMPLETED PRIOR TO CONSTRUCTION. (132/B66A RRH ORAN), ALTERATION,TO THE DOCUMENT, MOUNTED TO ANTENNA SLED MAST PIPE SITE INFORMATION NOTE., KING DANBY MICRO A STRUCTURAL ASSESSMENT OF THE EXISTING PROJECT#:20222362994 ASSUMED LOCATION OF ANTENNA FRAME IS TO BE COMPLETED PRIOR ASSUMED LOCATION OF EXISTING INTERIOR ELECTRIC TO CONSTRUCTION. EXISTING INTERIOR ELECTRIC LOCATION CODE:392588 SERVICE AND FIBER ROUTING NOTE: SERVICE AND FIBER ROUTING PROPOSED EQUIPMENT TO BE GROUNDED TO THE TOWN OF ITHACA EXISTING GROUND BAR WITHA#6 GREEN STRANDED COUNTY OF TOMPKINS INSULATED CONDUCTOR AND MECHANICAL 2-HOLE I I COMPRESSION LUG CONNECTIONS i I STATE OF NEW YORK SHEET TITLE EXISTING AND GRAPHIC SCALE GRAPHIC SCALE PROPOSED SITE PLANS 3 0 1.5 3 6 12 3 0 1.5 3 6 12 EXISTING SITE PLAN PROPOSED SITE PLAN C.E.JOB NUMBER SHEET NUMBER CC110CC110 SCALE: =3'(22 x 34 SHEET) IN FEET) 613 0.01 CC 110 SCALE:1"=3.((22 11 x 34 SHEET) (IN FEET) 1"=6'(11 x 17 SHEET) 1 inch= 3(ft.(22"x 34"SHEET) 1"=6' 11 x 17 SHEET) 1 inch= 3 ft.(22"x 34"SHEET) 1 inch= 6 fi.(11"x 17"SHEET) 1 inch 6 R.(II x 17"SHEET) SHEET 04 OF 07 EXISTING CANTENNA (NH360QM-DG-2XR) ANTENNA CENTERLINE=41.5'±AGL TO BE REMOVED verizon/ N EXISTING NON-PENETRATING 1275 JOHN STREET,SUITE#100 ANTENNA SLED WEST HENRIETTA,NEW YORK 14586 EXISTING GPS ANTENNA ATTACHED j,- LATA2.407629°(42"24'27.46"N) TO EXISTING ANTENNA SLED MASTLONG:-76.503817°(76°30'13.74"W) EX.UPPER ROOF PEAK ELEV.=35'-0"±AGL EXISTING BELL ATLANTIC MOBILE SYSTEMS LLC ROOFTOP ANTENNA LEASE AREA=4'-6"X 8'-0",36 f SQ.FT. 'z- EX.LOWER ROOF @ PEAK ELEV=30'-0"±AGL I 1 •CIVIL 7y ENGINEERING EXISTING CABLE ROUTING o •LAND (2)ANTENNA COAX CABLES SURVEYING (1)GPS COAX CABLE •LANDSCAPE ARCHITECTURE COSTICH 217—A,e EXISTING BUILDING � 1-11Tea.—lasoB ENGINEERING (585)45&3020 OVERHANG EXISTING WALL PENETRATION FOR ELECTRIC AND FIBER SERVICE EIH EXISTING LIGHT W/TIMER NO. DATE BY COMMENTS SWITCH BELOW —EXISTING PVC CONDUIT FOR VERTICAL CABLE ROUTING 0 01/16/2023 TKW REVIEW ISSUED PRELIMINARV FOR EXISTING RRH UNIT TQ BE REMQVED 1 02/02/2023 JK ISSUED FINAL FOR ' GRAPHIC SCALE PERMITTING r� E XISTING AC PANEL ` ® 6 0 3 6 12 24 FIBER ENCLOSURE TING RECEPTACLEI �I (IN FEET) EXISTING GENERATOR RECEPTACLE I inch- 6 ft.(22"x 34"SHEET) - - -EX.GROUND ELEV.=O'-0"±qGL 1 inch= 12 ft.(11"x 17"SHEET) �EXISTING EQUIPMENT I ITI'-III 'I ITI' IIIIII=IIII I1=III=III=I I1=III=III=III-III-ITI-III 'I ITI-ITI 'I EXISTING BELL ATLANTIC_I 'I -III-CABINET ITII ITI1I 1I1I1I IIII1I ITI1I ITI1I , EXISTING NORTH FACE ELEVATION 111 -11 -1 -11 -1 -11 -1 -11 -1 -11 -1 -1 -1 -1 1= -1 -1 -11 II -1 -11 -1 -11 -111111 -111 -111 -1 1 �� MOBILE SYSTEMS LLC EXTERIOR_ cczoo SCALE:1"-6'(22 x 34 SHEET) 111111 III11 III11 III11 III11 III1 -1 III III1111111 III11 III11 III1111111111111 1 I I1 I I1 I I1 I I1 I I1 I I1 I I1 I I1 I I1 I I1 I I1 I I1 I I1 I I1 I I1 I I1 I I1 I I1 I I1 I I1 11= GROUND EQUIPMENT LEASE I1 I I1 I I1 I I1 I I1 I I1 I I1 I I1 I I1 I I1 I I1 I I1 I I1 I I1 I I1 I I1 I I1 I I1 I I1 I I1 I I1 I I1 I I1 I I1 I I1 I I1 I I1 I II�' r=12'(11 x n SHEET) AREA=6-0"x 8'-0",48 f Sq.Ft. I=1 I I=1 I I=1 I I=1 I I=1 I I=1 I I=1 I I=1 I I=1 I I=1 I I=1 I I=1 I I=1 I I=1 I I1 I I1 I I1 I I1 I I1 I I1 I I1 I I1 i i= NOTE: EXISTING RF SIGNAGE AND BARRIERS SUBJECT PROPOSED CANTENNA TO CHANGE PENDING NEW RFE REPORT,WHICH (GALTRONICS:GQ24 18-0 7488) SHALL BE COMPLETED PRIOR TO CONSTRUCTION. ANTENNA CENTERLINE=41.54 AGL PROPOSED RRH UNIT PROJECT ANTENNA TIP PROPOSED CBRS RRH UNIT (B21B66A RRH ORAN), NOTE: F�M MANAGER ELEV=42.5't (RT440>48A), MOUNTED EXISTING ANTENNA SLED MAST PIPE A STRUCTURAL ASSESSMENT OF THE EXISTING P E R MOUNTED TO ANTENNA ANTENNA FRAME IS TO BE COMPLETED PRIOR h �� SLEDMASTPIPE EXISTING NON-PENETRATING TO CONSTRUCTION. a{T_F mid: ( ANTENNA SLED EXISTING GPS ANTENNA ATTACHED LAT:42.407629°(42"24'27.46"N) NOTE: ma I' ° i DRAWN BY TO EXISTING ANTENNA SLED MAST Zm gFc�p<' LONG:-76.503817°(76°30'13.74"W) EX.UPPER ROOF PEAK ELEV.=35'-0"±AGL PROPOSED EQUIPMENT TO BE GROUNDED TO THE oss�e4 '�2s dpldixlxlx MGM EXISTING BELL ATLANTIC MOBILE EXISTING GROUND BAR WITH A#6 GREEN STRANDED „xx"a T.K.W.SYSTEMS LLC ROOFTOP ANTENNA LEASE s INSULATED CONDUCTOR AND MECHANICAL 2-HOLE COMPRESSION LUG CONNECTIONS AREA=4'-6"X 8'-0",36 f SQ.FT. ���'< EX.LOWER ROOF @PEAK ELEV=30'-0"±AGL COPYRIGHT 2023 COSTICH ENGINEERING,D.P.C. Y NQTES: IT IS A VIOLATION OF LAW FOR ANV PERSON, ( • ALL CONDUIT,HARDWAREAND SUPPORTS TO UNLESS ACTING UNDER THE DIRECTION OF A EXISTING CABLE ROUTING F. BE PAINTED TO BLEND WITH EXISTING LICENSED PROFESSIONAL ENGINEER,LAND ' - .. SURVEYOR,ARCHITECT OR LNDSCAPE (2)ANTENNA COAX CABLES BUILDING. D ARCHITECT, RCHITrN TO ALTER AN ITEMONTHIS ANV LICENSEE WHO (1)GPS COAX CABLE ALTERS THIS DOCUMENT IS REQUIRED BY LAW EXISTING ANTENNA SLED INFORMATION TOALTE HIS/HERSEALNDTHE NOTATION PROPOSED CABLE ROUTING - I _ • LIMITED AT TIME OF DESIGN,CONTRACTOR TO "ATERED FOLLOWED ByHIHER SIGNATURE ANDD S SPECIFIC DESCRIPTIOON OF THE (10)ANTENNA COAX CABLES VERIFY EXISTING ANTENNA AZIMUTHAND PIPE ALTERATION,TO THE DOCUMENT, EXISTING BUILDING r—n LENGTH AND REPLACE EXISTING ANTENNA SITE INFORMATION L(OVERHANG i PROPOSED PVC CONDUIT FOR VERTICAL MAST PIPE IF NECESSARY TO REACH DESIRED ANTENNA CABLE ROUTING,TO BE SIZED PROPOSED AZIMUTH. KING DANBY MICRO EXISTING WALL PENETRATION FOR I TO ACCOMODA TE EXISTING AND ELECTRIC AND FIBER SERVICE ( PROJECT#:2�222362994 I PROPOSED CABLE ROUTING LOCATION CODE:392588 EXISTING LIGHT W/TIMER SWITCH BELOW TOWN OF ITHACA GRAPHIC SCALE COUNTY OF TOMPKINS EXISTING AC PANEL ; s o 3 s 12 za STATE OF NEW YORK EXISTING FIBER ENCLOSURE ® - ® MEN�%�illillill MINE SHEET TITLE u EXISTING RECEPTACLE �I (IN FEET) EXISTING AND EXISTING GENERATOR RECEPTACLE t inch= 6 ft.(22"x 34"SHEET) �I EX.GROUND ELEV.=0'-0"±AGL t inch= 12 ft.(11"x 17"SHEET) PROPOSED ELEVATIONS EXISTING EQUIPMENT C.E.JOB NUMBER SHEET NUMBER MOBILE SYSTEMS LLC EXTERRIOR CABINET c�PROPOSED NORTH FACE ELEVATION 6130.01 CC200 SCALE:1"=6'(22 x 34 SHEET) GROUND EQUIPMENT LEASE 1"=12'(11 x 17 SHEET) AREA=6-0"x W-0",48 f Sq.Ft. SHEET 05 OF 07 0J14.5" �14.96"� AMMIJIMIF S/S BELLEVILLE WASHER(TYP) Vel'�Z011`�S/S NUT(TYP) Y 'v S/S FLAT WASHER o (TYP)) 1275 JOHN STREET,SUITE#100 1„ WEST HENRIETTA,NEW YORK 14586 MIN. 1/8" AHMMIMMIME MIN. PLAN VIEW PLAN VIEW CLEAR HEAT SHRINK CLEAR HEAT SHRINK •CIVIL COPPER BUSS ENGINEERING LABEL LAND S/S FLAT WASHER(TYP) SURVEYING S/S BOLT TYP LANDSCAPE iQ (TYP) ARCHITECTURE rn v COSTICH 217L 1 ENGINEERING 585)45&3 AVENUE NOTE: R (_SM[R,rry 102046os 1. ALL HARDWARE 18-8 STAINLESS STEEL INCLUDING BELLEVILLES;COAT ALL SURFACES WITH NO-OX ID BEFORE MATING. 2. FOR GROUND BOND TO STEEL ONLY:INSERT A DRAGON TOOTH WASHER N BETWEEN LUG AND STEEL;COAT ALL SURFACES WITH NO-OX ID. NO. DATE BY COMMENTS 0 01/16/2023 TKW ISSUED PREUMINARVFOR CONCEAL FAB UNIVERSAL 7FRONT VIEW SIDE VIEW LUG GROUND CONNECTION REVIEW CANTENNA PIPE SLEEVE ISSUED FINAL FOR P/N:900192-F CC500 SCALE:NTS 1 02/02/2023 JK PERMITTING MODEL: RF4439D-25A, 74.7 LBS z RRH DETAIL CC500 SCALE: NTS MOUNTING BOLT ELEVATION VIEW FULL ASSEMBLY MODEL: GALTRONICS: GQ2418-7250 & GQ2418-7488 ANTENNA DETAIL CC500 SCALE: NTS PROJECT 5OFn"� F�M MANAGER DRAWN BY 6 ZN axidixxi M �O'`3 096 5 O 4 1 3 COPYRIGHT 2023 COSTICH ENGINEERING,D.P.C. PLAN VIEW 2 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER,LAND SURVEYOR,ARCHITECT OR LANDSCAPE � ARCHITECT,TO ALTER AN ITEM ON THIS 8.5" 4.2"� DOCUMENT IN ANY WAN.ANY LICENSEE WHO ALTERS THIS DOCUMENT IS REQUIRED BY LAW TO AFFIX HIS/HER SEAL AND THE NOTATION "ALTERED BY,FOLLOWED BY HIS/HER SIGNATURE AND SPECIFIC DESCRIPTION OF THE ALTERATION,TO THE DOCUMENT. L�-2.5" SITE INFORMATION KING DANBY MICRO r PARTS LIST PROJECT#:20222362994 ITEM# QUANTITY DESCRIPTION LOCATION CODE:392588 1 1 FLASHING,18"X 18"X.050",5052,MILL 2 1 QBLOCK,CLASSIC,A360 CAST AL,MILL 9" 3 1 HANGER BOLT,PLAIN CENTER,5116'X 6',18.8 SS TOWN T 4 1 WASHER,SEALING,511W ID X 3/4'OD,EPDM BONDED SS TO yy OF ITHACA 6 1 WASHER FLAT,19/14''F D X]1"DO X 1/8"EPDM COUNTY OF TOMPKINS N1 ] 1 WASHER,FENDER,5/1W ID X 1"OD,1&8 SS FRONT VIEW SIDE VIEW { 6 WASHER,SPLIT-LOCK,5/16"ID,18-8 SS STATE OF NEW YORK SHEET TITLE MODEL: RT4401-48A DETAILS SAMSUNG CBRS RRH QCONDUIT SUPPORT DETAIL CC500 SCALE: NTS CC500 C.E.JOB NUMBER SHEET NUMBER �J SCALE:NTS E 1 CC500 SHEET O6 OF 07 Antenna Summary Added ver 1 ZOn/ Make Model Centerline Tip Height Azimuth RET 4xRx Inst.Type Quantity Item ID 1275 JOHN STREET,SUITE#100 WEST HENRIETTA,NEW YORK 14586 Galtronies GQ2418-07488 415 42.5 30(A) false false PHYSICAL 1 Removed Make Model Centerline Tip Height Azimuth RET 4xRx Inst.Type Quantity Item ID CIVIL ANDREV/ NH360QM-DG-2XR 41_5 43.1 30(A) false false PHYSICAL 1 ENGINEERING LAND SURVEYING Retained •LANDSCAPE ARCHITECTURE Make Model Centerline Tip Height Azimuth RET 4xRx Inst.Type Quantity Item ID COSTICH 217-IE AVENGE RocHESTEa,NY 14608 ENGINEERING <aes/asasozo No data availabic NO. DATE BY COMMENTS 0 01/16/2023 TKW ISSUED PREUMINARYFOR REVIEW 1 02/02/2023 X ISSUED FINAL FOR PERMITTING 1711) Equipment Summary PROJECT Added OFnniN MANAGER PEA"R w "S = G� �% C.D.M. Equipment Type Location Make Model Cable Lengt Cable Size Install Typ Quantity Item ID Coaxial Cables Tower NIA 1/4""LDF Coax PHYSICAL 10 m2N I �` DRAWN BY oss�an,�e�s EssloNw T.K.W. B 2/B 6 6A RRH O RAN RRU Shelter Samsung PHYSICAL 1 (RF4439d-25A) COPYRIGHT 2023 COSTICH ENGINEERING,D.P.C. RRU Shelter Samsung CBRS RRH-RT4401-48A PHYSICAL 1 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER,LAND SURVEYOR,ARCHITECT OR LANDSCAPE Removed ARCHITECT,TO ALTER ANY ITEM ON THIS DOCUMENT IN ANY WAY.ANY LICENSEE WHO ALTERS THIS DOCUMENT IS REQUIRED BY LAW TO AFFIX HIS/HER SEAL AND THE NOTATION Equipment Type Location Make Model Cable Lengi Cable Size Install Typ Quantity Item ID "ALTERED BY",FOLLOWED BY HIS/HER SIGNATURE AND SPECIFIC DESCRIPTION OF THE ALTERATION,TO THE DOCUMENT. RRU ShPlirr Nok,I UHIE B66A RRH 4x45 PHYSICAL I SITE INFORMATION KING DANBY MICRO Retained PROJECT#:20222362994 LOCATION CODE:392588 Equipment Type Location Make Model Cable Lengt Cable Size Install Typ Quantity Item ID Coaxial Cables Tower N/A 1/4""LDF Coax PHYSICAL 2 TOWN OF ITHACA COUNTY OF TOMPKINS STATE OF NEW YORK SHEET TITLE RF INFORMATION C.E.JOB NUMBER SHEET NUMBER 6130.01 RF001 SHEET 07 OF 07