HomeMy WebLinkAbout31199___201 Cypress Ct. - Inspection Report 11.01.2023.pdf 310 W Green St VIRA Ithaca, NY 14850 {� Phone: 607-272-1234 Fax:607-272-2793 Town of Ithaca - General Fire Inspection Inspector Name: Jeff Cook Activity Number: FI-242-2023-0115.A Inspector Phone: 607-272-1234 Activity Cause: Reinspection Email: FPBMail@cityofithaca.org Activity Date: 10/05/23 09:00:00 AM Status: Pass 201 Cypress Court Atten: TOWN OF ITHACA Occupancy Type: R2 -Apartment/Multi-Dwelling Total Violations: 2 201 Cypress Ct Corrected Violations: 2 Ithaca, NY 14850 Hours: 1.00 A Fire Safety and Property Maintenance Inspection was performed at the location and address indicated above. You are requested to correct any violations that have been cited. Severe violations must be corrected immediately. All other violations must be corrected within 30 days of this report. Pre Existing Inspection Details Reference Number:2020 Fire Code of New York State 901.6.1 Standards. Fire protection systems shall be inspected,tested and maintained in accordance with the referenced standards listed in Table 901 6 1 (SEE BOOK) Corrected On: 11/01/2023 Comment: Sprinkler System due for 5 year internal inspection(NFPA 25). Reference Number: 2020 Fire Code of New York State 906.2 General requirements. Portable fire extinguishers shall be selected,installed and maintained in accordance with this section and NFPA 10 Exceptions: 1 The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1. Electronic monitoring shall confirm that extinguishers are properly positioned.properly charged and unobstructed 2 2 Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3. The extinguishers shall be installed inside of a budding or cabinet in a noncorrosive environment. 2.4. Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed 2 5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3 In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations Corrected On: 11/01/2023 Comment: Fire Extinguishers are required by code in all apartments-extinguisher size-2A1 011 Jeff Cook City of Ithaca Fire Department 310 W Green St Ithaca, New York14850 607-272-1234 jcook@cityofithaca.org Printed Date: 11/01/2023 Page 1 of 1